Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Bioengineering (Basel) ; 8(12)2021 Dec 08.
Article in English | MEDLINE | ID: mdl-34940356

ABSTRACT

BACKGROUND: A novel, wireless, ultrasound biosensor that adheres to the neck and measures real-time Doppler of the carotid artery may be a useful functional hemodynamic monitor. A unique experimental set-up during elective coronary artery bypass surgery is described as a means to compare the wearable Doppler to trans-esophageal echocardiography (TEE). METHODS: A total of two representative patients were studied at baseline and during Trendelenburg position. Carotid Doppler spectra from the wearable ultrasound and TEE were synchronously captured. Areas under the receiver operator curve (AUROC) were performed to assess the accuracy of changing common carotid artery velocity time integral (ccVTI∆) at detecting a clinically significant change in stroke volume (SV∆). RESULTS: Synchronously measuring and comparing Doppler spectra from the wearable ultrasound and TEE is feasible during Trendelenburg positioning. In two representative cardiac surgical patients, the ccVTI∆ accurately detected a clinically significant SV∆ with AUROCs of 0.89, 0.91, and 0.95 when single-beat, 3-consecutive beat and 10-consecutive beat averages were assessed, respectively. CONCLUSION: In this proof-of-principle research communication, a wearable Doppler ultrasound system is successfully compared to TEE. Preliminary data suggests that the diagnostic accuracy of carotid Doppler ultrasonography at detecting clinically significant SV∆ is enhanced by averaging more cardiac cycles.

2.
J Am Coll Emerg Physicians Open ; 2(4): e12533, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34401869

ABSTRACT

OBJECTIVE: Moderate-to-severe hemorrhage is a life-threatening condition, which is challenging to detect in a timely fashion using traditional vital signs because of the human body's robust physiologic compensatory mechanisms. Measuring and trending blood flow could improve diagnosis of clinically significant exsanguination. A lightweight, wireless, wearable Doppler ultrasound patch that captures and trends blood flow velocity could enhance hemorrhage detection. METHODS: In 11 healthy volunteers undergoing simulated hemorrhage and resuscitation during graded lower body negative pressure (LBNP) and release, we studied the relationship between stroke volume (SV) and common carotid artery velocity time integral (VTI) and corrected flow time (FTc). We assessed the diagnostic accuracy of 2 variations of a novel metric, the Doppler shock index (ie, the DSIVTI and DSIFTc), at capturing moderate-to-severe central hypovolemia defined as a 30% reduction in SV. The DSIVTI and DSIFTc are calculated as the heart rate divided by either the VTI or FTc, respectively. RESULTS: A total of 17,822 cardiac cycles were analyzed across 22 LBNP protocols. The average SV reduction to the lowest tolerated LBNP stage was 40%; there was no clinically significant fall in the mean arterial pressure. Correlations between changing SV and the common carotid artery VTI and FTc were strong (R 2 of 0.87, respectively) and concordant. The DSIVTI and DSIFTc accurately detected moderate-to-severe central hypovolemia with values for the area under the receiver operator curves of 0.96 and 0.97, respectively. CONCLUSION: In a human model of hemorrhage and resuscitation, measures from a wearable Doppler ultrasound patch correlated strongly with SV and identified moderate-to-severe central hypovolemia with excellent diagnostic accuracy.

3.
PLoS One ; 14(8): e0221501, 2019.
Article in English | MEDLINE | ID: mdl-31465478

ABSTRACT

Recent research has shown Major League Baseball (MLB) players that bat left-handed and throw right-handed, otherwise known as sinister right-handers, are more likely to have a career batting average (BA) of .299 or higher compared to players with other combinations of batting and throwing handedness. Moreover, possibly owing to early exposure to hockey, Canadian-born MLB players have an increased propensity to be sinister right-handers, however, it has yet to be determined whether this provides a relative offensive performance advantage compared to players born in other countries. Using the largest archival dataset of MLB statistics available, the present study examined the independent influence of batting (i.e., left, right, switch) and throwing (i.e., left, right) handedness combinations and country/region of origin (i.e., Canada, USA, Latin America, Asia, Other) on several indices of offensive performance including BA, slugging percentage (SLG), on-base plus slugging (OPS), on-base plus slugging plus (OPS+), home runs (HR), runs batted in (RBI), strikeouts (SO) and wins above replacement (WAR). Mediation models were also computed to examine whether birthplace influences offensive performance through handedness. Examination of all recorded MLB batters revealed that batting left, regardless of throwing handedness, confers an offensive performance advantage. Since the inception of the MLB, the relative proportion of Canadian-born sinister right-handers is at least two times greater than players from other regions, although being Canadian-born does not provide a direct offensive advantage. Rather, results showed evidence of a significant indirect effect in that being Canadian-born increases the odds of being a sinister right-hander and in turn leads to greater performance across each offensive performance statistic. Collectively, findings provide further support for the hockey influence on batting hypothesis and suggest this effect extends to offensive performance.


Subject(s)
Athletic Performance , Baseball , Functional Laterality , Analysis of Variance , Canada , Female , Hockey , Humans , Male , Models, Theoretical
4.
Science ; 309(5734): 591-4, 2005 Jul 22.
Article in English | MEDLINE | ID: mdl-16040702

ABSTRACT

We describe a new strategy for the in situ growth of molecular wires predicated on the synthesis of a trifunctional "primed" contact formed from metal-carbon multiple bonds. The ruthenium-carbon pi bond provides structural stability to the molecular linkages under ambient conditions, and density functional calculations indicate the formation of an efficient conduit for charge carriers to pass between the metal and the molecule. Moreover, the metal-carbon pi bond provides a chemically reactive site from which a conjugated molecular wire can be grown in situ through an olefin metathesis reaction.

SELECTION OF CITATIONS
SEARCH DETAIL
...