Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
2.
J Radiat Res ; 64(6): 911-925, 2023 Nov 21.
Article in English | MEDLINE | ID: mdl-37816672

ABSTRACT

Several staffing models are used to determine the required medical physics staffing, including radiotherapy technologists, of radiation oncology departments. However, since Japanese facilities tend to be smaller in scale than foreign ones, those models might not apply to Japan. Therefore, in this study, we surveyed workloads in Japan to estimate the optimal medical physics staffing in external beam radiotherapy. A total of 837 facilities were surveyed to collect information regarding radiotherapy techniques and medical physics specialists (RTMPs). The survey covered facility information, staffing, patient volume, equipment volume, workload and quality assurance (QA) status. Full-time equivalent (FTE) factors were estimated from the workload and compared with several models. Responses were received from 579 facilities (69.2%). The median annual patient volume was 369 at designated cancer care hospitals (DCCHs) and 252 across all facilities. In addition, the median FTE of RTMPs was 4.6 at DCCHs and 3.0 at all sites, and the average QA implementation rate for radiotherapy equipment was 69.4%. Furthermore, advanced treatment technologies have increased workloads, particularly in computed tomography simulations and treatment planning tasks. Compared to published models, larger facilities (over 500 annual patients) had a shortage of medical physics staff. In very small facilities (about 140 annual patients), the medical physics staffing requirement was estimated to be 0.5 FTE, implying that employing a full-time medical physicist would be inefficient. However, ensuring the quality of radiotherapy is an important issue, given the limited number of RTMPs. Our study provides insights into optimizing staffing and resource allocation in radiotherapy departments.


Subject(s)
Neoplasms , Radiation Oncology , Humans , Workload , Japan , Surveys and Questionnaires , Neoplasms/radiotherapy , Physics
3.
J Appl Clin Med Phys ; 22(8): 255-264, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34272814

ABSTRACT

A realistic X-ray energy spectrum is essential for accurate dose calculation using the Monte Carlo (MC) algorithm. An energy spectrum for dose calculation in the radiation treatment planning system is modeled using the MC algorithm and adjusted to obtain acceptable agreement with the measured percent depth dose (PDD) and off-axis ratio. The simulated energy spectrum may not consistently reproduce a realistic energy spectrum. Therefore, direct measurement of the X-ray energy spectrum from a linac is necessary to obtain a realistic spectrum. Previous studies have measured low photon fluence directly, but the measurement was performed with a nonclinical linac with a thick target and a long target-to-detector distance. In this study, an X-ray energy spectrum from a clinical linac was directly measured using a NaI(Tl) scintillator at an ultralow dose rate achieved by adjusting the gun grid voltage. The measured energy spectrum was unfolded by the Gold algorithm and compared with a simulated spectrum using statistical tests. Furthermore, the PDD was calculated using an unfolded energy spectrum and a simulated energy spectrum was compared with the measured PDD to evaluate the validity of the unfolded energy spectrum. Consequently, there was no significant difference between the unfolded and simulated energy spectra by nonparametric, Wilcoxon's rank-sum, chi-square, and two-sample Kolmogorov-Smirnov tests with a significance level of 0.05. However, the PDD calculated from the unfolded energy spectrum better agreed with the measured compared to the calculated PDD results from the simulated energy spectrum. The adjustment of the incident electron parameters using MC simulation is sensitive and takes time. Therefore, it is desirable to obtain the energy spectrum by direct measurement. Thus, a method to obtain the realistic energy spectrum by direct measurement was proposed in this study.


Subject(s)
Particle Accelerators , Photons , Computer Simulation , Humans , Monte Carlo Method , Radiography , X-Rays
4.
J Appl Clin Med Phys ; 18(6): 71-78, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28895278

ABSTRACT

For patient setup of the IGRT technique, various imaging systems are currently available. MV portal imaging is performed in identical geometry with the treatment beam so that the portal image provides accurate geometric information. However, MV imaging suffers from poor image contrast due to larger Compton scatter photons. In this work, an original image processing algorithm is proposed to improve and enhance the image contrast without increasing the imaging dose. Scatter estimation was performed in detail by MC simulation based on patient CT data. In the image processing, scatter photons were eliminated and then they were reprojected as primary photons on the assumption that Compton interaction did not take place. To improve the processing efficiency, the dose spread function within the EPID was investigated and implemented on the developed code. Portal images with and without the proposed image processing were evaluated by the image contrast profile. By the subtraction process, the image contrast was improved but the EPID signal was weakened because 15.2% of the signal was eliminated due to the contribution of scatter photons. Hence, these scatter photons were reprojected in the reprojection process. As a result, the tumor, bronchi, mediastinal space and ribs were observed more clearly than in the original image. It was clarified that image processing with the dose spread functions provides stronger contrast enhancement while maintaining a sufficient signal-to-noise ratio. This work shows the feasibility of improving and enhancing the contrast of portal images.


Subject(s)
Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Monte Carlo Method , Pelvis/diagnostic imaging , Phantoms, Imaging , Radiography, Thoracic , Algorithms , Humans , Photons , Scattering, Radiation , Signal-To-Noise Ratio
5.
Radiat Prot Dosimetry ; 163(2): 148-59, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24821930

ABSTRACT

The physical data regarding bremsstrahlung and neutrons produced in a steel shield by high-energy electron beams from a medical linear accelerator were investigated. These data are required to allow the accurate prediction of shielding performance for high-energy electron beams and in the design of radiotherapy facilities. A Monte Carlo code was used to develop Monte Carlo beam models for clinical electron beams and to directly simulate bremsstrahlung and secondary neutron production in a steel shield. The effective dose and dose equivalent of bremsstrahlung X rays and secondary neutrons outside a vault were determined using a realistic radiation source. The accuracy of Monte Carlo simulations was validated experimentally by comparing the measured and calculated physical quantities. In validating the Monte Carlo simulation, the measured and calculated values showed reasonable agreement, indicating that bremsstrahlung and photoneutron production and transport were simulated accurately. The bremsstrahlung X-ray dose was the main component of the total dose outside a vault. The secondary neutron dose was 1-20 % of the bremsstrahlung X-ray dose, but the neutron dose was also at a non-negligible level. The calculated neutron dose outside the vault differed from the McGinley's reported data. These results indicate that McGinley's method overestimates the neutron dose beyond the steel shield. The physical data used here will be useful in the accurate estimation of bremsstrahlung X-ray and neutron doses for high-energy electron beams.


Subject(s)
Models, Statistical , Neutrons , Radiation Protection/instrumentation , Radiometry/methods , Radiotherapy, High-Energy/instrumentation , Computer Simulation , Equipment Design , Equipment Failure Analysis , Monte Carlo Method , Particle Accelerators , Photons , Radiotherapy Dosage , Scattering, Radiation
6.
J Radiat Res ; 51(6): 707-13, 2010.
Article in English | MEDLINE | ID: mdl-20972364

ABSTRACT

To reduce the uncertainty of absorbed dose for high energy photon beams, water has been chosen as a reference material by the dosimetry protocols. However, solid phantoms are used as media for absolute dose verification of intensity modulated radiotherapy (IMRT). For the absorbed dose measurement, the fluence scaling factor is used for converting an ionization chamber reading in a solid phantom to absorbed dose to water. Furthermore the depth scaling factor is indispensable in determining the fluence scaling factor. For IMRT beams, a photon energy spectrum is varied by transmitting through a multileaf collimator and attenuating in media. However, the effects of spectral variations on depth scaling have not been clarified yet. In this study, variations of photon energy spectra were determined using the EGS Monte Carlo simulation. The depth scaling factors for commercially available solid phantoms were determined from effective mass attenuation coefficients using photon energy spectra. The results clarified the effect of spectral variation on the depth scaling and produced an accurate scaling method for IMRT beams.


Subject(s)
Phantoms, Imaging , Radiotherapy, Intensity-Modulated , Computer Simulation , Humans , Monte Carlo Method , Particle Accelerators , Phantoms, Imaging/statistics & numerical data , Photons/therapeutic use , Radiometry/methods , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/statistics & numerical data
7.
J Radiat Res ; 50(4): 363-9, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19542692

ABSTRACT

Many medical linear accelerators generate not only high-energy photons, but also high-energy electrons, and they are no longer equipped with beam stoppers. Therefore, shields might be necessary against bremsstrahlung and photoneutron generated by high-energy electron beams. However, there are few physical studies, and no recommendations are made about shields nowadays. In this report, the leakage doses of bremsstrahlung and photoneutron were calculated by the use of Monte Carlo simulation. To verify the calculated results, the photoneutron leakage dose was measured with a rem counter. The results clearly show that the bremsstrahlung and photoneutron leakage dose generated by electron beams of 24 MeV or below is negligible.


Subject(s)
Electrons , Models, Theoretical , Particle Accelerators/instrumentation , Radiation Protection/instrumentation , Radiometry/methods , Steel , Computer Simulation , Equipment Design , Equipment Failure Analysis , Materials Testing , Monte Carlo Method , Neutrons , Radiation Protection/methods , Scattering, Radiation
8.
Med Phys ; 35(10): 4591-8, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18975705

ABSTRACT

This article is intended to improve the certainty of the absorbed dose determination for reference dosimetry in CyberKnife beams. The CyberKnife beams do not satisfy some conditions of the standard reference dosimetry protocols because of its unique treatment head structure and beam collimating system. Under the present state of affairs, the reference dosimetry has not been performed under uniform conditions and the beam quality correction factor kQ for an ordinary 6 MV linear accelerator has been temporally substituted for the kQ of the CyberKnife in many sites. Therefore, the reference conditions and kQ as a function of the beam quality index in a new way are required. The dose flatness and the error of dosimeter reading caused by radiation fields and detector size were analyzed to determine the reference conditions. Owing to the absence of beam flattening filter, the dose flatness of the CyberKnife beam was inferior to that of an ordinary 6 MV linear accelerator. And if the absorbed dose is measured with an ionization chamber which has cavity length of 2.4, 1.0 and 0.7 cm in reference dosimetry, the dose at the beam axis for a field of 6.0 cm collimator was underestimated 1.5%, 0.4%, and 0.2% on a calculation. Therefore, the maximum field shaped with a 6.0 cm collimator and ionization chamber which has a cavity length of 1.0 cm or shorter were recommended as the conditions of reference dosimetry. Furthermore, to determine the kQ for the CyberKnife, the realistic energy spectrum of photons and electrons in water was simulated with the BEAMnrc. The absence of beam flattening filter also caused softer photon energy spectrum than that of an ordinary 6 MV linear accelerator. Consequently, the kQ for ionization chambers of a suitable size were determined and tabulated as a function of measurable beam quality indexes in the CyberKnife beam.


Subject(s)
Radiometry/methods , Radiometry/standards , Radiosurgery/instrumentation , Radiosurgery/standards , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/standards , Algorithms , Computer Simulation , Humans , Models, Biological , Monte Carlo Method , Radiosurgery/methods , Reference Values , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity , United Kingdom
9.
Igaku Butsuri ; 27(3): 129-35, 2008.
Article in Japanese | MEDLINE | ID: mdl-18367823

ABSTRACT

To establish traceability of absorbed dose to water, a cobalt calibration coefficient is transferred to a reference ionization chamber by the standard dosimetry laboratory in the radiotherapy field. In Japan, the calibration is done against a set of an ionization chamber and an electrometer as a system. Nowadays, solely electrometer calibration is desirable to measure absorbed dose with more than one combination of ionization chamber and electrometer. Unfortunately, there is no domestic electrometer calibration service for nano-ampere range appropriate for ionization current measurement in the radiotherapy field. In this report, a relative electrometer calibration factor was determined by comparison between a calibrated combination and a non-calibrated electrometer under identical irradiation conditions at the user site. To estimate uncertainties of user electrometer calibration, comparison was made between calibration factors obtained by ionization current under a linac photon beam and DC current with a precision DC source instrument. It was found that the variation of electrometer readings to pulse ionization current is negligible under the steady photon beam output and dose monitor system. Therefore relative electrometer calibration under identical irradiation conditions at the user site was judged valid until a domestic nano-ampere electrometer calibration service becomes available.


Subject(s)
Particle Accelerators , Radiometry , Calibration , Japan , Radiometry/instrumentation , Radiotherapy Dosage , Water
10.
Med Phys ; 33(12): 4635-42, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17278816

ABSTRACT

We are investigating three-dimensional converging stereotactic radiotherapy (3DCSRT) with suitable medium-energy x rays as treatment for small lung tumors with better dose homogeneity at the target. A computed tomography (CT) system dedicated for non-coplanar converging radiotherapy was simulated with BEAMnrc (EGS4) Monte-Carlo code for x-ray energy of 147.5, 200, 300, and 500 kilovoltage (kVp). The system was validated by comparing calculated and measured percentage of depth dose in a water phantom for the energy of 120 and 147.5 kVp. A thorax phantom and CT data from lung tumors (<20 cm3) were used to compare dose homogeneities of kVp energies with MV energies of 4, 6, and 10 MV. Three non-coplanar arcs (0 degrees and +/-25 degrees ) around the center of the target were employed. The Monte Carlo dose data format was converted to the XiO RTP format to compare dose homogeneity, differential, and integral dose volume histograms of kVp and MV energies. In terms of dose homogeneity and DVHs, dose distributions at the target of all kVp energies with the thorax phantom were better than MV energies, with mean dose absorption at the ribs (human data) of 100%, 85%, 50%, 30% for 147.5, 200, 300, and 500 kVp, respectively. Considering dose distributions and reduction of the enhanced dose absorption at the ribs, a minimum of 500 kVp is suitable for the lung kVp 3DCSRT system.


Subject(s)
Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/instrumentation , Radiotherapy/methods , Tomography, X-Ray Computed/methods , Computer Simulation , Humans , Lung/diagnostic imaging , Lung/pathology , Models, Theoretical , Monte Carlo Method , Phantoms, Imaging , Radiography, Thoracic/instrumentation , Radiography, Thoracic/methods , Stereotaxic Techniques , Water/chemistry , X-Rays
11.
Radiat Med ; 22(4): 233-8, 2004.
Article in English | MEDLINE | ID: mdl-15468943

ABSTRACT

To experimentally and theoretically evaluate dose distribution during lung stereotactic radiotherapy, we investigated the relative electron densities in lung and tumor tissues using X-ray computed tomography images obtained from 30 patients in three breathing states: free breathing, inspiration breath-hold, and expiration breath-hold. We also calculated dose distribution using Monte Carlo simulation for lung tissue with two relative electron densities. The effect of changes in relative electron density on dose distribution in lung tissue was evaluated using calculated differential and integral dose volume histograms. The relative electron density of lung tissue was 0.22 in free breathing, 0.23 in shallow expiration, and 0.17 in shallow inspiration, and there was a tendency for relative electron density to decrease with age. The relative electron density of tumor tissue was approximately 0.9, with little variation due to differences in breathing state. As the relative electron density of lung tissue decreases, the low-dose region expands and leads to changes in the marginal dose.


Subject(s)
Lung Neoplasms/radiotherapy , Lung/radiation effects , Stereotaxic Techniques , Age Factors , Aged , Electrons , Exhalation/physiology , Female , Humans , Inhalation/physiology , Lung/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Male , Monte Carlo Method , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Respiration , Tomography, Spiral Computed , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...