Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Lancet Digit Health ; 6(5): e345-e353, 2024 May.
Article in English | MEDLINE | ID: mdl-38670743

ABSTRACT

BACKGROUND: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. METHODS: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. FINDINGS: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6-19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). INTERPRETATION: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. FUNDING: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.


Subject(s)
Artificial Intelligence , Capsule Endoscopy , Gastrointestinal Hemorrhage , Intestine, Small , Humans , Capsule Endoscopy/methods , Gastrointestinal Hemorrhage/diagnosis , Prospective Studies , Female , Male , Middle Aged , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Aged , Adult , Aged, 80 and over , Neural Networks, Computer
2.
Gastrointest Endosc ; 2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38272273

ABSTRACT

BACKGROUND AND AIMS: Small bowel (SB) capsule endoscopy (CE) is a first line procedure for exploring the SB. Endoscopic GastroIntestinal PlacemenT (EGIPT) of SB CE is sometimes necessary. While the experience of EGIPT is large in pediatric populations, we aimed to describe the safety, efficacy and outcomes of EGIPT of SB CE in adult patients. METHODS: The international CApsule endoscopy REsearch (iCARE) group set up a retrospective multicenter study. Patients over 18 year-old who underwent EGIPT of SB CE before May 2022 were included. Data were collected from medical records and capsule recordings. The primary endpoint was the technical success rate of the EGIPT procedures. RESULTS: 630 patients were included (mean age 62.5 years old, 55.9% female) from 39,565 patients (1.6%) issued from 29 centers. EGIPT technical success was achieved in 610 procedures (96.8%). Anesthesia (moderate/deep sedation or general anesthesia) and centers with intermediate or high procedure loads were independent factors of technical success. Severe adverse events occurred in three (0.5%) patients. When technically successful, EGIPT was associated with a high SB CE completion rate (84.4%) and with a substantial diagnostic yield (61.1%). Completion rate was significantly higher when the capsule was delivered in the SB compared to when delivered in the stomach. CONCLUSION: EGIPT of SB CE is highly feasible, safe and comes with high completion rate and diagnostic yield. When indicated, it should rather be performed under anesthesia and the capsule should be delivered in the duodenum rather than in the stomach, for better SB examination outcomes.

3.
Diagnostics (Basel) ; 12(7)2022 Jul 13.
Article in English | MEDLINE | ID: mdl-35885608

ABSTRACT

(1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.

4.
Diagnostics (Basel) ; 13(1)2022 Dec 21.
Article in English | MEDLINE | ID: mdl-36611310

ABSTRACT

Colon capsule endoscopy (CCE) is a promising modality for colonic investigations, but completion rates (CR) and adequate cleansing rates (ACR) must be improved to meet established standards for optical colonoscopy. Improvements should be made with patient acceptability in mind. We aimed to compare a very low-volume polyethylene glycol (PEG) laxative to a conventional high-volume laxative. We carried out a single-center retrospective comparative cohort study including patients referred for CCE. One hundred and sixty-six patients were included in the final analysis, with eighty-three patients in each group. We found a CR and ACR of 77% and 67% in the high-volume group and 72% and 75% in the very low-volume group, respectively. In the high-volume group, 54% had complete transit and adequate cleansing, whereas this was the case for 63% in the very low-volume group. No statistically significant difference in CR, ACR, or a combination of the two was found. A very low-volume bowel preparation regimen was non-inferior to a high-volume regimen before CCE in terms of CR and ACR.

5.
Gastrointest Endosc ; 94(3): 589-597.e1, 2021 09.
Article in English | MEDLINE | ID: mdl-33848508

ABSTRACT

BACKGROUND AND AIMS: Little is known about small-bowel (SB) capsule endoscopy (CE) in patients with a history of gastric surgery. This study aims to evaluate the feasibility and diagnostic yield (DY) of orally ingested SB-CE in patients with surgically altered gastric anatomy. METHODS: Twenty-four European centers retrospectively identified patients who had SB-CE after total or subtotal gastrectomy. The primary outcome was the DY of SB-CE (intermediate P1 to highly P2 relevant findings). Secondary outcomes were gastric and SB transit times, completion, cleanliness, and adverse event rates. RESULTS: Studied were 248 procedures from 243 patients (mean age, 62 years) with a history of partial gastrectomy (Billroth I, 13.1%; Billroth II, 34.6%), total gastrectomy (7.4%), Whipple procedure (12.8%), sleeve gastrectomy (7.2%), or gastric bypass surgery (24.7%). Obscure GI bleeding was the most frequent indication (85.1%). SB completion rate was 84.3%. One capsule retention in the SB was noted (adverse event rate, .4%). Median SB transit time was 286 minutes (interquartile range [235; 387]). Cleanliness was rated as adequate in 92.1% of procedures. After exclusion of abnormalities found at the upper anastomotic site, the DY was 43.6%, with inflammatory/ulcerated lesions observed more frequently (23.4%) than vascular lesions (21.0%). CONCLUSIONS: SB-CE seems to be feasible and safe in selected patients with a history of major gastric surgery and comes with a high DY. The spectrum of abnormal SB findings in these patients may be different from what is known from the literature in nonoperated patients.


Subject(s)
Capsule Endoscopy , Feasibility Studies , Gastrointestinal Hemorrhage/etiology , Humans , Intestine, Small , Middle Aged , Retrospective Studies
6.
Endosc Int Open ; 9(1): E22-E30, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33403232

ABSTRACT

Background and study aims The aim of this study was to elucidate the differences in image-enhanced endoscopy (IEE) findings between Helicobacter - pylori -associated and autoimmune gastritis. Patients and methods Seven H. pylori -naïve, 21 patients with H. pylori -associated gastritis and seven with autoimmune gastritis were enrolled. Mucosal atrophy in the corpus was evaluated using autofluorescence imaging and classified into small, medium and large. In a 2 × 2-cm area of the lesser curvature of the lower corpus, micromucosal pattern was evaluated by magnifying narrow band imaging and proportion of foveola (FV)- and groove (GR)-type mucosa was classified into FV > 80 %, FV 50 % to 80 %, GR 50 % to 80 %, and GR > 80 %, then a biopsy specimen was taken. Results Fifteen of 21 (71 %) H. pylori -associated gastritis patients exhibited medium-to-large atrophic mucosa at the corpus lesser curvature. All autoimmune gastritis patients had large atrophic mucosa throughout the corpus ( P  < 0.001). All H. pylori -naïve patients had the FV > 80 % micromucosal pattern. Nineteen of 21 (90 %) H. pylori -associated gastritis patients had varying proportions of GR- and FV-type mucosae and five of seven (71 %) autoimmune gastritis patients showed FV > 80 % mucosa ( P  < 0.001). Compared with patients who were H. pylori -naïve, patients with H. pylori -associated and autoimmune gastritis exhibited a higher grade of atrophy ( P  < 0.001), but only patients with H. pylori -associated gastritis showed a higher grade of intestinal metaplasia ( P  = 0.022). Large mucosal atrophy with FV > 80 % micromucosal pattern had sensitivity of 71 % (95 % CI: 29 %-96 %) and specificity of 100 % (95 % CI: 88 % to 100 %) for diagnosis of autoimmune gastritis. Conclusions IEE findings of the gastric corpus differed between H. pylori -associated and autoimmune gastritis, suggesting different pathogenesis of the two diseases.

7.
J Clin Med ; 9(9)2020 09 15.
Article in English | MEDLINE | ID: mdl-32942749

ABSTRACT

BACKGROUND: Conventional colonoscopy (CC) allows access for colonic investigation and intervention; in the small group in whom CC is unsuccessful alternative imaging is often sufficient. There remains a subset, however, requiring full colonic visualisation or intervention. Balloon-assisted colonoscopy (BAC) gives a further option when access is difficult. Aims: This study aims to present the experience with BAC of two European tertiary referral centres. Methods: Procedures were carried out under local protocol over 15-years (2006-2020). Markers of procedural quality such as caecal intubation, complications and comfort were retrospectively compiled and analysed. Published evidence was summarised for comparison. Results: 122 procedures were undertaken, with polyps the most frequent indication and 90.2% having at least one previously incomplete CC. Features associated with difficult colonoscopy were common, including intraabdominal surgery (32.0%). 92.6% reached the caecum; completion was higher (96.3%) in those failing CC due to discomfort and lower in those failing due to anatomical difficulties (90.7%) or previous surgery (84.6%). Mean time to the caecum was 20.9 minutes and mean midazolam and fentanyl doses were 2.6 mg and 49.9 µg with low discomfort scores. Conclusion(s): Balloon-assisted colonoscopy is successful in >90% of patients, is well-tolerated, and is safe.

8.
United European Gastroenterol J ; 8(1): 99-107, 2020 02.
Article in English | MEDLINE | ID: mdl-32213061

ABSTRACT

BACKGROUND: In the medical literature, the nomenclature and descriptions (ND) of small bowel (SB) ulcerative and inflammatory (U-I) lesions in capsule endoscopy (CE) are scarce and inconsistent. Inter-observer variability in interpreting these findings remains a major limitation in the assessment of the severity of mucosal lesions, which can impact negatively on clinical care, training and research on SB-CE. OBJECTIVE: Focusing on SB-CE in Crohn's disease (CD), our aim is to establish a consensus on the ND of U-I lesions. METHODS: An international panel of experienced SB-CE readers was formed during the 2016 United European Gastroenterology Week meeting. A core group of five CE and inflammatory bowel disease (IBD) experts established an Internet-based, three-round Delphi consensus but did not participate in the voting process. The core group built illustrated questionnaires, including SB-CE still frames of U-I lesions from patients with documented CD. Twenty-seven other experts were asked to rate and comment on the different proposals for the ND of the most frequent SB U-I lesions. For each round, we used a 6-point rating scale (varying from 'strongly disagree' to 'strongly agree'). The consensus was reached when at least 80 % of the voting members scored the statement within the 'agree' or 'strongly agree' categories. RESULTS: A 100% participation rate was obtained for all the rounds. Consensual ND were reached for the following seven U-I lesions: aphthoid erosion, deep ulceration, superficial ulceration, stenosis, edema, hyperemia and denudation. CONCLUSION: Considering the most frequent SB U-I lesions seen in CE in CD, a consensual ND was reached by the international group of experts. These descriptions and names are useful not only for daily practice and medical education, but also for medical research.


Subject(s)
Capsule Endoscopy/standards , Crohn Disease/diagnosis , Intestine, Small/diagnostic imaging , Terminology as Topic , Consensus , Crohn Disease/immunology , Crohn Disease/pathology , Delphi Technique , Gastroenterology/standards , Humans , International Cooperation , Intestine, Small/immunology , Intestine, Small/pathology , Observer Variation , Semantics
9.
J Clin Med ; 8(11)2019 Nov 11.
Article in English | MEDLINE | ID: mdl-31718057

ABSTRACT

Data on malignancy in patients with collagenous colitis (CC) is scarce. We aimed to determine the incidence of cancers in patients with CC. In a two-stages, observational study, data on cancers in patients diagnosed with CC during 2000-2015, were collected from two cohorts. The risk was calculated according to the age-standardized rate for the first cohort and according to the standardized incidence ratio for the second cohort. The first cohort comprised 738 patients (394 from Scotland and 344 from Sweden; mean age 71 ± 11 and 66 ± 13 years, respectively). The incidence rates for lung cancer (RR 3.9, p = 0.001), bladder cancer (RR 9.2, p = 0.019), and non-melanoma skin cancer (NMSC) (RR 15, p = 0.001) were increased. As the majority of NMSC cases (15/16) came from Sweden, a second Swedish cohort, comprising 1141 patients (863 women, mean age 65 years, range 20-95 years) was collected. There were 93 cancer cases (besides NMSC). The risk for colon cancer was decreased (SIR 0.23, p= 0.0087). The risk for cutaneous squamous cell carcinoma was instead markedly increased (SIR 3.27, p = 0.001).

10.
Endosc Int Open ; 7(3): E372-E379, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30834297

ABSTRACT

Background and study aims Nomenclature and descriptions of small bowel (SB) vascular lesions in capsule endoscopy (CE) are scarce in the medical literature. They are mostly based on the reader's opinion and thus differ between experts, with a potential negative impact on clinical care, teaching and research regarding SBCE. Our aim was to better define a nomenclature and to give a description of the most frequent vascular lesions in SBCE. Methods A panel of 18 European expert SBCE readers was formed during the UEGW 2016 meeting. Three experts constructed an Internet-based four-round Delphi consensus, but did not participate in the voting process. They built questionnaires that included various still frames of vascular lesions obtained with a third-generation SBCE system. The 15 remaining participants were asked to rate different proposals and description of the most common SB vascular lesions. A 6-point rating scale (varying from 'strongly disagree' to 'strongly agree') was used successive rounds. The consensus was reached when at least 80 % voting members scored the statement within the 'agree' or 'strongly agree'. Results Consensual terms and descriptions were reached for angiectasia/angiodysplasia, erythematous patch, red spot/dot, and phlebectasia. A consensual description was reached for more subtle vascular lesions tentatively named "diminutive angiectasia" but no consensus was reached for this term. Conclusion An international group has reached a consensus on the nomenclature and descriptions of the most frequent and relevant SB vascular lesions in CE. These terms and descriptions are useful in daily practice, for teaching and for medical research purposes.

11.
Therap Adv Gastroenterol ; 11: 1756284818758929, 2018.
Article in English | MEDLINE | ID: mdl-29531578

ABSTRACT

BACKGROUND: Video capsule endoscopy (VCE) is a noninvasive method enabling excellent visualization of the small bowel (SB) mucosa. The aim of this study was to examine the impact and safety of VCE performed in children and adolescents with suspected or established Crohn's disease (CD). METHODS: A total of 180 VCE examinations in 169 consecutive patients conducted in 2003-14 in a single center were retrospectively analyzed. The median age was 13 years (range 3-17 years) and indications for VCE were suspected (125 cases, 69%) and established (55 cases, 31%) CD. VCE was performed with a PillCam SB (Given Imaging, Yokneam, Israel) VCE system with 8-12 h of registration without bowel preparation. RESULTS: A total of 154 of 180 (86%) patients swallowed the capsule and 26 (14%) had the capsule endoscopically placed in the duodenum. Patency capsule examination was performed in 71 cases prior to VCE to exclude SB obstruction. VCE detected findings consistent with SB CD in 71 (40%) examinations and 17 (9%) procedures showed minor changes not diagnostic for CD. A total of 92 (51%) examinations displayed normal SB mucosa. The capsule did not reach the colon within the recording time in 30 (17%) procedures and were defined as incomplete examinations. A change in diagnosis or therapy was recommended in 56 (31%) patients based on VCE results. Capsule retention occurred in one patient. CONCLUSIONS: VCE is a safe method in children with suspected or established CD. VCE often leads to a definitive diagnosis and has a significant impact on the clinical management of pediatric patients with CD.

12.
United European Gastroenterol J ; 5(7): 974-981, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29163963

ABSTRACT

BACKGROUND: Recent data imply young patients (age ≤50 years) undergoing small-bowel (SB) capsule endoscopy (CE) for iron deficiency anaemia (IDA) show higher diagnostic yield (DY) for sinister pathology. We aimed to investigate DY of CE in a large cohort of young IDA patients, and evaluate factors predicting significant SB pathology. MATERIALS AND METHODS: This was a retrospective, multicentre study (2010-2015) in consecutive, young patients (≤50 years) from 18 centres/12 countries, with negative bidirectional gastrointestinal (GI) endoscopy undergoing SBCE for IDA. Exclusion criteria: previous/ongoing obscure-overt GI bleeding; age <19 or >50 years; comorbidities associated with IDA. Data retrieved: SBCE indications; prior investigations; medications; SBCE findings; final diagnosis. Clinical and laboratory data were analysed by multivariate logistic regression. RESULTS: Data on 389 young IDA patients were retrieved. In total, 169 (43.4%) were excluded due to incomplete clinical data; data from 220 (122F/98M; mean age 40.5 ± 8.6 years) patients were analysed. Some 71 patients had at least one clinically significant SBCE finding (DY: 32.3%). They were divided into two groups: neoplastic pathology (10/220; 4.5%), and non-neoplastic but clinically significant pathology (61/220; 27.7%). The most common significant but non-neoplastic pathologies were angioectasias (22/61) and Crohn's disease (15/61). On multivariate analysis, weight loss and lower mean corpuscular volume(MCV) were associated with significant SB pathology (OR: 3.87; 95%CI: 1.3-11.3; p = 0.01; and OR: 0.96; 95%CI: 0.92-0.99; p = 0.03; respectively). Our model also demonstrates association between use of antiplatelets and significant SB pathology, although due to the small number of patients, definitive conclusions cannot be drawn. CONCLUSION: In IDA patients ≤50 years with negative bidirectional GI endoscopy, overall DY of SBCE for clinically significant findings was 32.3%. Some 5% of our cohort was diagnosed with SB neoplasia; lower MCV or weight loss were associated with higher DY for SB pathology.

13.
United European Gastroenterol J ; 5(5): 677-686, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28815031

ABSTRACT

BACKGROUND: The most concerning complication of video capsule endoscopy (VCE) is capsule retention (CR) in the gastrointestinal (GI) tract although clinical outcome and management of patients with CR are still uncertain in a large single center material. OBJECTIVES: The aim of this retrospective study was to investigate incidence, causes, risk factors, management and clinical outcomes of CR in a large single center between 2001 and 2011. RESULTS: 2401 consecutive small-bowel (SB) VCEs were performed. CR was detected in 25 cases (1%). CR in patients with suspected and known Crohn's disease (CD) undergoing VCE occurred in 14/1370 (1%) including known CD 9/390 (2.3%) and suspected CD 5/980 (0.5%). CR in patients with obscure GI bleeding was observed in 11/816 (1.3%) cases. The SB was the most common site of CR with 17 cases followed by the esophagus (4 cases), colon (2 cases), and stomach (2 cases). Emergency endoscopic intervention (3 cases) and surgery (2 cases) was needed in 5 cases of CR. Elective capsule removal was performed by surgery in 6 cases and endoscopically in 8 cases. Three retained capsules dislodged after steroid treatment and another 3 cases of CR resolved without any intervention. CONCLUSION: This large clinical material demonstrates that CR is a rare complication with a favorable clinical outcome. Most patients with CR can be electively managed with non-surgical intervention.

15.
Endosc Int Open ; 5(6): E477-E483, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28580415

ABSTRACT

BACKGROUND AND AIMS: Capsule endoscopy (CE) has revolutionized small-bowel (SB) investigation. Computational methods can enhance diagnostic yield (DY); however, incorporating machine learning algorithms (MLAs) into CE reading is difficult as large amounts of image annotations are required for training. Current databases lack graphic annotations of pathologies and cannot be used. A novel database, KID, aims to provide a reference for research and development of medical decision support systems (MDSS) for CE. METHODS: Open-source software was used for the KID database. Clinicians contribute anonymized, annotated CE images and videos. Graphic annotations are supported by an open-access annotation tool (Ratsnake). We detail an experiment based on the KID database, examining differences in SB lesion measurement between human readers and a MLA. The Jaccard Index (JI) was used to evaluate similarity between annotations by the MLA and human readers. RESULTS: The MLA performed best in measuring lymphangiectasias with a JI of 81 ±â€Š6 %. The other lesion types were: angioectasias (JI 64 ±â€Š11 %), aphthae (JI 64 ±â€Š8 %), chylous cysts (JI 70 ±â€Š14 %), polypoid lesions (JI 75 ±â€Š21 %), and ulcers (JI 56 ±â€Š9 %). CONCLUSION: MLA can perform as well as human readers in the measurement of SB angioectasias in white light (WL). Automated lesion measurement is therefore feasible. KID is currently the only open-source CE database developed specifically to aid development of MDSS. Our experiment demonstrates this potential.

16.
Ann Transl Med ; 5(9): 195, 2017 May.
Article in English | MEDLINE | ID: mdl-28567375

ABSTRACT

BACKGROUND: Colon capsule endoscopy (CCE) offers direct mucosal visualisation without sedation or gas insufflation required in conventional colonoscopy (CC). However, evidence for the role of CCE as an adjunct or alternative to CC remains equivocal. In this observational cohort study, we report our experience of using CCE to investigate patients with suspected colon pathology at a tertiary referral centre. METHODS: From 2007-2015, consecutive patients requiring colonoscopy were recruited from a tertiary care centre in Malmo, Sweden. Data collected: patient demographics, indication for CCE, findings, bowel cleansing, colon transit time (CTT) and completeness of colon examination. RESULTS: Seventy-seven patients (57 F/20 F, median age 56 years) were included. The reason for CCE was previously incomplete or refused CC in 39 and 26 cases, and follow up of previous findings in 12 cases, respectively. The main clinical indications were gastrointestinal (GI) bleeding (n=28; 36%) and suspected inflammatory bowel disease (IBD) or follow-up of known IBD (n=23; 30%). CCE was complete in 58/77 (75%) patients. In 3 patients the colon was not reached; in the other 16, the capsule reached the rectum (n=4), sigmoid (n=6), descending colon (n=5) and transverse colon (n=1). Findings were: normal CCE (n=15; 19%) colonic diverticula (n=29; 38%), polyps (n=17; 22%), active IBD (n=12; 16%), haemorrhoids (n=8; 10%), colonic angioectasia (n=4; 5%) and cancer (n=1; 1%). Small-bowel findings were recorded in 8 (10%) patients. All patients tolerated bowel preparation and CCE well. Two patients with an ulcerated small-bowel stricture and cancer respectively experienced temporary capsule retention with spontaneous resolution. CONCLUSIONS: CCE is a well-tolerated alternative to CC, but requires technological improvement and optimisation of clinical practice to meet current reference standards. Although further technical development is required, CCE may complement or even replace CC for certain clinical indications.

17.
Ann Transl Med ; 5(9): 199, 2017 May.
Article in English | MEDLINE | ID: mdl-28567379

ABSTRACT

Video capsule endoscopy (VCE) has become the method of choice for visualizing the small bowel mucosa and is generally considered to be a safe method. Although uncommon, the most feared complication of VCE is capsule retention that can potentially lead to life-threatening bowel obstruction. Herein, we present for the first time a case of capsule retention in a colonic stent. The patient had known Crohn's disease with colonic involvement and underwent an uneventful but incomplete small bowel VCE for assessment of disease activity and extension for optimizing medical treatment. Five months later, the patient presented with intestinal obstruction due to a Crohn's-stricture in the sigmoid colon, which was successfully decompressed with a self-expandable metal stent. Nonetheless, two days later the patient showed signs of bowel obstruction again and abdominal X-ray showed that the capsule was trapped in the metal stent in the sigmoid colon. Subsequently, emergency surgery was performed and the patient fully recovered. Intestinal capsule retention necessitating interventional removal is rare. This report describes a unique case of capsule retention in a colonic metal stent and highlights the potential risk of performing capsule endoscopy examinations in patients with gastrointestinal stents.

18.
Ann Gastroenterol ; 30(3): 309-314, 2017.
Article in English | MEDLINE | ID: mdl-28469361

ABSTRACT

BACKGROUND: Collagenous colitis (CC) is by definition a histological diagnosis. However, colonoscopy often reveals characteristic endoscopic findings. The aim of this study was to evaluate the frequency and type of endoscopic findings in patients diagnosed with CC in 4 participating centers. METHODS: This was a retrospective study; the databases of 2 university hospitals in Edinburgh (Scotland) and Malmö (Sweden), and 2 district general hospitals in Tomelloso (Spain) and Gateshead (England) were interrogated for patients diagnosed with CC between May 2008 and August 2013. Endoscopy reports and images were retrieved and reviewed; data on lesions, sedation, bowel preparation and endoscopist experience were abstracted. Categorical data are reported as mean±SD. Fischer's exact, chi-square and t (unpaired) tests were used to compare datasets. A two-tailed P-value of <0.05 was considered statistically significant. RESULTS: 607 patients (149 male, mean age 66.9±12.25 years) were diagnosed with CC. A total of 108/607 (17.8%) patients had one or more suggestive endoscopy findings: i.e., mucosal erythema/edema, 91/607 (15%); linear colonic mucosal defects, 12/607 (2%); or mucosal scarring, 5/607 (0.82%). For colonic mucosa erythema, there was no difference in the odds of finding erythema with the use of different bowel preparation methods (P=0.997). For colonic mucosal defects there was some evidence (P=0.005) that patients colonoscoped by experienced endoscopists had 87% less odds of developing such defects. Moreover, there was evidence that analgesia reduced the odds of developing mucosal defects by 84%. CONCLUSION: A significant minority of patients with CC have endoscopic findings in colonoscopy. The description of such findings appears to be related to the endoscopist's experience.

20.
Lakartidningen ; 1142017 05 15.
Article in Swedish | MEDLINE | ID: mdl-28510243

ABSTRACT

High quality colonoscopy must be secured Colonoscopy plays a key role in the work-up of digestive diseases and constitutes the cornerstone in colorectal cancer diagnosis and prevention. Data suggest that the quality of colonoscopy varies widely between different endoscopists. This article summarizes current evidence and expert consensus on quality indicators, along with the evidence supporting their use in benchmarking, quality reporting, and continuous quality improvement in order to secure high quality colonoscopy. In particular, four quality indicators, i.e. adenoma detection rate, compliance with guidelines on intervals for endoscopic surveillance, cecal intubation rate and complications, should be monitored in endoscopy units to ensure that colonoscopy practice is of high quality. Proper performance and documentation of high quality colonoscopy is critical for reducing colorectal cancer incidence and mortality.


Subject(s)
Colonoscopy/standards , Quality Assurance, Health Care , Quality Indicators, Health Care , Adenoma/diagnosis , Adenoma/prevention & control , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/prevention & control , Guideline Adherence , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...