Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Medicina (Kaunas) ; 59(7)2023 Jul 15.
Article in English | MEDLINE | ID: mdl-37512121

ABSTRACT

Background and Objectives: The aim of this study was to investigate under dynamic loading the potential biomechanical benefit of simulated first tarsometatarsal (TMT-1) fusion with low-profile superelastic nitinol staples used as continuous compression implants (CCIs) in two different configurations in comparison to crossed screws and locked plating in a human anatomical model. Materials and Methods: Thirty-two paired human anatomical lower legs were randomized to four groups for TMT-1 treatment via: (1) crossed-screws fixation with two 4.0 mm fully threaded lag screws; (2) plate-and-screw fixation with a 4.0 mm standard fully threaded cortex screw, inserted axially in lag fashion, and a 6-hole TMT-1 Variable-Angle (VA) Fusion Plate 2.4/2.7; (3) CCI fixation with two two-leg staples placed orthogonally to each other; (4) CCI fixation with one two-leg staple and one four-leg staple placed orthogonally to each other. Each specimen was biomechanically tested simulating forefoot weightbearing on the toes and metatarsals. The testing was performed at 35-37 °C under progressively increasing cyclic axial loading until construct failure, accompanied by motion tracking capturing movements in the joints. Results: Combined adduction and dorsiflexion movement of the TMT-1 joint in unloaded foot condition was associated with no significant differences among all pairs of groups (p ≥ 0.128). In contrast, the amplitude of this movement between unloaded and loaded foot conditions within each cycle was significantly bigger for the two CCI fixation techniques compared to both crossed-screws and plate-and-screw techniques (p ≤ 0.041). No significant differences were detected between the two CCI fixation techniques, as well as between the crossed-screws and plate-and-screw techniques (p ≥ 0.493) for this parameter of interest. Furthermore, displacements at the dorsal and plantar aspects of the TMT-1 joint in unloaded foot condition, together with their amplitudes, did not differ significantly among all pairs of groups (p ≥ 0.224). Conclusions: The low-profile superelastic nitinol staples demonstrate comparable biomechanical performance to established crossed-screws and plate-and-screw techniques applied for fusion of the first tarsometatarsal joint.


Subject(s)
Foot , Metatarsal Bones , Humans , Alloys , Biomechanical Phenomena , Bone Plates , Cadaver , Metatarsal Bones/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...