Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Radiother Oncol ; : 110289, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38944554

ABSTRACT

BACKGROUND AND PURPOSE: Guideline adherence in radiotherapy is crucial for maintaining treatment quality and consistency, particularly in non-trial patient settings where most treatments occur. The study aimed to assess the impact of guideline changes on treatment planning practices and compare manual registry data accuracy with treatment planning data. MATERIALS AND METHODS: This study utilised the DBCG RT Nation cohort, a collection of breast cancer radiotherapy data in Denmark, to evaluate adherence to guidelines from 2008 to 2016. The cohort included 7448 high-risk breast cancer patients. National guideline changes included, fractionation, introduction of respiratory gating, irradiation of the internal mammary lymph nodes, use of the simultaneous integrated boost technique and inclusion of the Left Anterior Descending coronary artery in delineation practice. Methods for structure name mapping, laterality detection, detection of temporal changes in population mean lung volume, and dose evaluation were presented and applied. Manually registered treatment characteristic data was obtained from the Danish Breast Cancer Database for comparison. RESULTS: The study found immediate and consistent adherence to guideline changes across Danish radiotherapy centres. Treatment practices before guideline implementation were documented and showed a variation among centres. Discrepancies between manual registry data and actual treatment planning data were as high as 10% for some measures. CONCLUSION: National guideline changes could be detected in the routine treatment data, with a high degree of compliance and short implementation time. Data extracted from treatment planning data files provides a more accurate and detailed characterisation of treatments and guideline adherence than medical register data.

2.
Radiother Oncol ; 182: 109448, 2023 05.
Article in English | MEDLINE | ID: mdl-36566988

ABSTRACT

BACKGROUND AND PURPOSE: Daily plan adaptations could take the dose delivered in previous fractions into account. Due to high dose delivered per fraction, low number of fractions, steep dose gradients, and large interfractional organ deformations, this might be particularly important for liver SBRT. This study investigates inter-algorithm variation of interfractional dose accumulation for MR-guided liver SBRT. MATERIALS AND METHODS: We assessed 27 consecutive MR-guided liver SBRT treatments of 67.5 Gy in three (n = 15) or 50 Gy in five fractions (n = 12), both prescribed to the GTV. We calculated fraction doses on daily patient anatomy, warped these doses to the simulation MRI using seven different algorithms, and accumulated the warped doses. Thus, we obtained differences in planned doses and warped or accumulated doses for each algorithm. This enabled us to calculate the inter-algorithm variations in warped doses per fraction and in accumulated doses per treatment course. RESULTS: The four intensity-based algorithms were more consistent with planned PTV dose than affine or contour-based algorithms. The mean (range) variation of the dose difference for PTV D95% due to dose warping by these intensity-based algorithms was 10.4 percentage points (0.3 to 43.7) between fractions and 8.6 (0.3 to 24.9) between accumulated treatment doses. As seen by these ranges, the variation was very dependent on the patient and the fraction being analyzed. Nevertheless, no correlations between patient or plan characteristics on the one hand and inter-algorithm dose warping variation on the other hand was found. CONCLUSION: Inter-algorithm dose accumulation variation is highly patient- and fraction-dependent for MR-guided liver SBRT. We advise against trusting a single algorithm for dose accumulation in liver SBRT.


Subject(s)
Radiosurgery , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Liver/diagnostic imaging , Algorithms
3.
Strahlenther Onkol ; 198(5): 436-447, 2022 05.
Article in English | MEDLINE | ID: mdl-34528112

ABSTRACT

PURPOSE: The purpose of this study was to evaluate our 2 years' experience with single-isocenter, non-coplanar, volumetric modulated arc therapy (VMAT) for brain metastasis (BM) stereotactic radiosurgery (SRS). METHODS: A total of 202 patients treated with the VMAT SRS solution were analyzed retrospectively. Plan quality was assessed for 5 mm (120) and 2.5 mm (high-definition, HD) central leaf width multileaf collimators (MLCs). For BMs at varying distances from the plan isocenter, the geometric offset from the ideal position for two image-guided radiotherapy workflows was calculated. In the workflow with ExacTrac (BrainLAB, München, Germany; W­ET), patient positioning errors were corrected at each couch rotation. In the workflow without ExacTrac (W-noET), only the initial patient setup correction was considered. The dose variation due to rotational errors was simulated for multiple-BM plans with the HD-MLC. RESULTS: Plan conformity and quality assurance were equivalent for plans delivered with the two MLCs while the HD-MLC plans provided better healthy brain tissue (BmP) sparing. 95% of the BMs had residual intrafractional setup errors ≤ 2 mm for W­ET and 68% for W­noET. For small BM (≤1 cc) situated >3 cm from the plan isocenter, the dose received by 95% of the BM decreased in median (interquartile range) by 6.3% (2.8-8.8%) for a 1-degree rotational error. CONCLUSION: This study indicates that the HD-MLC is advantageous compared to the 120-MLC for sparing healthy brain tissue. When a 2-mm margin is applied, W­noET is sufficient to ensure coverage of BM situated ≤ 3 cm of the plan isocenter, while for BM further away, W­ET is recommended.


Subject(s)
Brain Neoplasms , Radiotherapy, Intensity-Modulated , Brain Neoplasms/secondary , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies
4.
J Appl Clin Med Phys ; 20(9): 61-68, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31478615

ABSTRACT

PURPOSE: The purpose of the study was to investigate if surface guided radiotherapy (SGRT) can decrease setup deviations for tangential and locoregional breast cancer patients compared to conventional laser-based setup (LBS). MATERIALS AND METHODS: Both tangential (63 patients) and locoregional (76 patients) breast cancer patients were enrolled in this study. For LBS, the patients were positioned by aligning skin markers to the room lasers. For the surface based setup (SBS), an optical surface scanning system was used for daily setup using both single and three camera systems. To compare the two setup methods, the patient position was evaluated using verification imaging (field images or orthogonal images). RESULTS: For both tangential and locoregional treatments, SBS decreased the setup deviation significantly compared to LBS (P < 0.01). For patients receiving tangential treatment, 95% of the treatment sessions were within the clinical tolerance of ≤ 4 mm in any direction (lateral, longitudinal or vertical) using SBS, compared to 84% for LBS. Corresponding values for patients receiving locoregional treatment were 70% and 54% for SBS and LBS, respectively. No significant difference was observed comparing the setup result using a single camera system or a three camera system. CONCLUSIONS: Conventional laser-based setup can with advantage be replaced by surface based setup. Daily SGRT improves patient setup without additional imaging dose to breast cancer patients regardless if a single or three camera system was used.


Subject(s)
Brachytherapy/standards , Breast Neoplasms/radiotherapy , Patient Positioning , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy Setup Errors/prevention & control , Radiotherapy, Image-Guided/standards , Adult , Aged , Aged, 80 and over , Breast Neoplasms/diagnostic imaging , Female , Humans , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Middle Aged , Organs at Risk/radiation effects , Prognosis , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...