Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Microbiol ; 46(10): 3319-24, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18701669

ABSTRACT

A new rapid immunochromatographic assay based on the signal amplification system (SAS) has been developed by Diagnostics for the Real World (Europe) Ltd. for the detection of hepatitis B virus surface antigen (HBsAg) in plasma or serum specimens. The SAS format features enhanced sensitivity as a result of an increased binding valence of the detector molecules. We have now evaluated the performance of the new HBsAg rapid test (DRW-HBsAg) in comparison with a well-established commercial rapid test (Determine HBsAg; previously from Abbott Laboratories; now from Inverness Medical Innovations) and with a CE-marked enzyme immunoassay (EIA) (Hepanostika HBsAg Ultra; BioMérieux) as the gold standard. Testing of serially diluted in-house HBsAg-positive samples, the World Health Organization standard, and sensitivity and reference panels yielded an analytical sensitivity for the DRW test of 0.2 to 0.8 IU/ml across HBsAg serotypes. Evaluation with eight commercially available seroconversion panels showed that the DRW-HBsAg test detected HBsAg an average of 6.1 days (range, 3 to 8 days) earlier than the Determine assay (P = 0.0078). Test sensitivity was also examined with two low-titer HBsAg EIA-positive panels in Beijing, China. Whereas 100% of these samples were detected by the DRW-HBsAg test, only 15.0% (P < 0.0001) and 87.3% (P < 0.0001), respectively, were detected by the Determine HBsAg test. The performance of the DRW-HBsAg test was further evaluated with samples determined to be HBsAg positive or negative by the EIA in Conakry, Guinea, and Beijing, China. No significant difference in sensitivity between the DRW and Determine tests was apparent with the HBsAg EIA-reactive samples from Guinea (96.7% versus 94.4%, respectively) or China (99.46 versus 98.92%, respectively). The specificity of the Determine HBsAg test was slightly higher than that of DRW-HBsAg test (100 versus 99.2%, respectively) with samples from EIA-negative blood donors in China. In conclusion, the new DRW HBsAg rapid test is more sensitive than the Determine HBsAg test and is suitable for diagnostic and blood screening in resource-limited settings.


Subject(s)
Hepatitis B Surface Antigens/blood , Hepatitis B virus/isolation & purification , Hepatitis B/diagnosis , Virology/methods , Humans , Sensitivity and Specificity , Serologic Tests/methods
2.
J Clin Microbiol ; 46(4): 1466-9, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18234860

ABSTRACT

First-void urine (FVU) is the preferred specimen for the diagnosis of urogenital Chlamydia trachomatis infection in men. We have developed FirstBurst, a urine collection device that collects the first 4 to 5 ml of FVU and yields a specimen with a sixfold higher C. trachomatis organism load than the regular urine cup by quantitative PCR (32,533 versus 5,271 plasmids/ml; P < 0.0001). Consequently, the use of FirstBurst to collect a urine sample improved the sensitivity of a rapid test for Chlamydia over testing of samples collected with a urine cup (82 versus 47% sensitivity using PCR as a reference; P < 0.0015).


Subject(s)
Chlamydia Infections/diagnosis , Chlamydia trachomatis/isolation & purification , Specimen Handling/instrumentation , Specimen Handling/methods , Urine/microbiology , Adolescent , Adult , Chlamydia Infections/microbiology , Chlamydia trachomatis/genetics , Humans , Male , Polymerase Chain Reaction/methods , Sensitivity and Specificity
3.
J Clin Microbiol ; 45(12): 4011-7, 2007 Dec.
Article in English | MEDLINE | ID: mdl-17942659

ABSTRACT

The prevalence of urogenital Chlamydia trachomatis infection was determined with a PCR-based test of women from low- and high-risk populations in Iloilo City, Philippines, between August 2002 and March 2006. Two rapid tests for C. trachomatis, Clearview Chlamydia MF and the Chlamydia Rapid Test (CRT), were also evaluated in these resource-limited settings. Specimens were obtained from female sex workers (FSWs; n = 1,484) attending a social hygiene clinic (SHC) and from women (n = 838) attending an obstetrics-gynecology (OB-GYN) clinic. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the rapid tests were determined, with PCR as the gold standard. The PCR positivity rate for SHC participants (72% asymptomatic) ranged from 17.9 to 32.0% during the study period. Compared with those of PCR, the sensitivities and specificities of the Clearview test were 53.5 and 99.1%, respectively, with endocervical swab specimens (CS; n = 822) from the FSWs and 31.1 and 95.2%, respectively, with vaginal swab specimens (VS; n = 333) from these women. The sensitivity, specificity, PPV, and NPV of the CRT with VS from the FSWs were 71.0, 99.0, 97.1, and 87.9%, respectively. At the OB-GYN site, the PCR positivity rate with VS was 6.3%. The sensitivity, specificity, PPV, and NPV of the CRT with these specimens were 86.8, 99.6, 93.9, and 99.1%, respectively. The performance of the Clearview test at the SHC was thus markedly lower with VS than with CS, whereas the CRT performed well with VS from both populations.


Subject(s)
Cervix Uteri/virology , Chlamydia Infections/epidemiology , Chlamydia Infections/microbiology , Chlamydia trachomatis/isolation & purification , Polymerase Chain Reaction/methods , Vagina/virology , Adolescent , Adult , Female , Humans , Middle Aged , Philippines/epidemiology , Predictive Value of Tests , Sensitivity and Specificity
4.
J Clin Microbiol ; 45(5): 1395-402, 2007 May.
Article in English | MEDLINE | ID: mdl-17376879

ABSTRACT

Urethral and endocervical swabs and self-collected vaginal swabs (SCVSs) and urine specimens are all used as samples for diagnosis of urogenital infection with Chlamydia trachomatis. We have now determined chlamydial organism load in matched specimens from different anatomic sites and examined its relation to clinical signs and symptoms in men and women. Organism load was measured with assays based on the ligase chain reaction or real-time PCR analysis. The mean organism loads in 58 infected men were 1,200 and 821 elementary bodies (EBs) per 100 microl of sample for first-void urine (FVU) and urethral swabs, respectively (P>0.05). Organism load in FVU samples or urethral swabs was positively associated with symptoms (P<0.01) and clinical signs (P<0.01) in men. The mean organism loads in 73 infected women were 2,231, 773, 162, and 47 EBs/100 microl for endocervical swabs, SCVSs, urethral swabs, and FVU samples, respectively (P<0.001 for each comparison). Only the presence of multiple symptoms or clinical signs was associated with organism load in women. These results show that FVU is a suitable noninvasive sample type for men, given the fact that its chlamydial load did not differ significantly from that of urethral swabs. Given their higher organism load compared with FVU, SCVSs are the preferred noninvasive sample type for women.


Subject(s)
Chlamydia Infections/diagnosis , Chlamydia trachomatis/isolation & purification , Mass Screening/methods , Cervix Uteri/microbiology , Chlamydia Infections/urine , Female , Humans , Male , Urethra/microbiology , Urethral Diseases/diagnosis , Urethral Diseases/microbiology , Uterine Cervical Diseases/diagnosis , Uterine Cervical Diseases/microbiology , Vagina/microbiology , Vaginal Diseases/diagnosis , Vaginal Diseases/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...