Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 17(2)2024 Jan 12.
Article in English | MEDLINE | ID: mdl-38255551

ABSTRACT

Antibiotic-resistant bacteria, ESKAPE pathogens, present a significant and alarming threat to public health and healthcare systems. This study addresses the urgent need to combat antimicrobial resistance by exploring alternative ways to reduce the health and cost implications of infections caused by these pathogens. To disrupt their transmission, integrating antimicrobial textiles into personal protective equipment (PPE) is an encouraging avenue. Nevertheless, ensuring the effectiveness and safety of these textiles remains a persistent challenge. To achieve this, we conduct a comprehensive study that systematically compares the effectiveness and potential toxicity of five commonly used antimicrobial agents. To guide decision making, a MULTIMOORA method is employed to select and rank the optimal antimicrobial textile finishes. Through this approach, we determine that silver nitrate is the most suitable choice, while a methoxy-terminated quaternary ammonium compound is deemed less favorable in meeting the desired criteria. The findings of this study offer valuable insights and guidelines for the development of antimicrobial textiles that effectively address the requirements of effectiveness, safety, and durability. Implementing these research outcomes within the textile industry can significantly enhance protection against microbial infections, contribute to the improvement of public health, and mitigate the spread of infectious diseases.

2.
Materials (Basel) ; 15(16)2022 Aug 22.
Article in English | MEDLINE | ID: mdl-36013923

ABSTRACT

Thermophysiological comfort is known to play a primary role in maintaining thermal balance, which corresponds to a person's satisfaction with their immediate thermal environment. Among the existing test methods, sweating torsos are one of the best tools to provide a combined measurement of heat and moisture transfer using non-isothermal conditions. This study presents a preliminary numerical model of a single sector sweating torso to predict the thermophysiological comfort properties of fabric systems. The model has been developed using COMSOL Multiphysics, based on the ISO 18640-1 standard test method and a single layer fabric system used in sportswear. A good agreement was observed between the experimental and numeral results over different exposure phases simulated by the torso test (R2 = 0.72 to 0.99). The model enables a systematic investigation of the effect of fabric properties (thickness, porosity, thermal resistance, and evaporative resistance), environmental conditions (relative humidity, air and radiant temperature, and wind speed), and physiological parameters (sweating rate) to gain an enhanced understanding of the thermophysiological comfort properties of the fabric system.

3.
PLoS One ; 17(4): e0265126, 2022.
Article in English | MEDLINE | ID: mdl-35390014

ABSTRACT

The World Health Organization has advocated mandatory face mask usage to combat the spread of COVID-19, with multilayer masks recommended for enhanced protection. However, this recommendation has not been widely adopted, with noncompliant persons citing discomfort during prolonged usage of face masks. And yet, a scientific understanding on how face mask fabrics/garment systems affect thermophysiological comfort remains lacking. We aimed to investigate how fabric/garment properties alter the thermal and evaporative resistances responsible for thermophysiological strain. We constructed 12 different layered facemasks (D1-D5, T1-T6, Q1) with various filters using commercially available fabrics. Three approaches were employed: (1) the evaporative and thermal resistances were measured in all the test face masks using the medium size to determine the effect of fabric properties; (2) the effect of face mask size by testing close-fitted (small), fitted (medium) and loose fitted (large) face mask T-6; (3) the effect of face mask fit by donning a large size face mask T-6, both loose and tightened using thermal manikin, Newton. ANOVA test revealed that the additional N95 middle layer filter has no significant effect on the thermal resistances of all the face masks, and evaporative resistances except for face masks T-2 and T-3 (P-values<0.05) whereas size significantly affected thermal and evaporative resistances (P-values<0.05). The correlation coefficient between the air gap size and the thermal and evaporative resistance of face masks T-6 were R2 = 0.96 and 0.98, respectively. The tight fit large face mask had superior performance in the dissipation of heat and moisture from the skin (P-values <0.05). Three-layer masks incorporating filters and water-resistant and antimicrobial/antiviral finishes did not increase discomfort. Interestingly, using face masks with fitters improved user comfort, decreasing thermal and evaporative resistances in direct opposition to the preconceived notion that safer masks decrease comfort.


Subject(s)
COVID-19 , Masks , COVID-19/prevention & control , Humans , Manikins , Textiles
4.
Sci Rep ; 11(1): 14775, 2021 07 20.
Article in English | MEDLINE | ID: mdl-34285253

ABSTRACT

Infection diagnosis and antibiotic susceptibility testing (AST) are pertinent clinical microbiology practices that are in dire need of improvement, due to the inadequacy of current standards in early detection of bacterial response to antibiotics and affordability of contemporarily used methods. This paper presents a novel way to conduct AST which hybridizes disk diffusion AST with microwave resonators for rapid, contactless, and non-invasive sensing and monitoring. In this research, the effect of antibiotic (erythromycin) concentrations on test bacterium, Escherichia coli (E. coli) cultured on solid agar medium (MH agar) are monitored through employing a microwave split-ring resonator. A one-port microwave resonator operating at a 1.76 GHz resonant frequency, featuring a 5 mm2 sensitive sensing region, was designed and optimized to perform this. Upon introducing uninhibited growth of the bacteria, the sensor measured 0.005 dB/hr, with a maximum change of 0.07 dB over the course of 15 hours. The amplitude change decreased to negligible values to signify inhibited growth of the bacteria at higher concentrations of antibiotics, such as a change of 0.005 dB in resonant amplitude variation while using 45 µg of antibiotic. Moreover, this sensor demonstrated decisive results of antibiotic susceptibility in under 6 hours and shows great promise to expand automation to the intricate AST workflow in clinical settings, while providing rapid, sensitive, and non-invasive detection capabilities.


Subject(s)
Anti-Bacterial Agents/pharmacology , Biosensing Techniques/instrumentation , Culture Media/pharmacology , Escherichia coli/growth & development , Bacteriological Techniques/instrumentation , Culture Media/chemistry , Disk Diffusion Antimicrobial Tests , Electromagnetic Fields , Erythromycin/pharmacology , Escherichia coli/drug effects , Microwaves
5.
J Hazard Mater ; 409: 124945, 2021 05 05.
Article in English | MEDLINE | ID: mdl-33418298

ABSTRACT

Protective clothing must repel hazardous liquids such as oils, acids, and solvents, which often exhibit low surface tension. The low surface tension liquid repellency of textiles is currently characterized qualitatively, considering only the first thirty seconds of wetting. This study demonstrates that embedded sensors within protective fabrics can more fully characterize liquid repellency while simultaneously detecting the hazardous substance. The liquid repellency of oleophobic textiles was detected in-situ using differential planar microwave resonator structures. A differential split ring resonator was designed with resonant responses at 4.4 and 4.6 GHz with a sensitivity of 50 MHz per unit ε. Fabrics were rendered oleophobic by dip-coating. The liquid repellency was monitored in-situ using droplets of heptane, octane, decane, dodecane, and water. Wetting transitions and droplet evaporation were identified in real time. The 4.4 GHz resonance peak's shift was used to measure the liquid repellency, whereas the 4.6 GHz resonator monitored the liquid's vapor as it absorbed into a gas-sensitive elastomer. The microwave response was tracked over 10 h every 15 s, and this transient data could identify the liquids based on their wetting and evaporation rates. Such sensors could be readily embedded in oleophobic textiles and enhance personal protective equipment.

6.
IEEE Trans Biomed Circuits Syst ; 15(1): 122-132, 2021 02.
Article in English | MEDLINE | ID: mdl-33513106

ABSTRACT

A real-time and label-free microstrip sensor capable of detecting and monitoring subsurface growth of Escherichia coli (E. coli) on solid growth media such as Luria-Bertani (LB) agar is presented. The microwave ring resonator was designed to operate at 1.76 GHz to detect variations in the dielectric properties such as permittivity and loss tangent to monitor bacterial growth. The sensor demonstrated high efficiency in monitoring subsurface dynamics of E. coli growth between two layers of LB agar. The resonant amplitude variations (Δ Amplitude (dB)) were recorded for different volumes of E. coli (3 µL and 9 µL) and compared to control without E. coli for 36 hours. The control showed a maximum amplitude variation of 0.037 dB, which was selected as a threshold to distinguish between the presence and absence of E. coli growth. The measured results by sensors were further supported by microscopic images. It is worth noticing that the amplitude variations fit well with the Gompertz growth model. The rate of amplitude change correlating bacteria growth rate was calculated as 0.08 and 0.13 dB/hr. for 3 µL and 9 µL of E. coli, respectively. This work is a proof of concept to demonstrate the capability of microwave sensors to detect and monitor subsurface bacterial growth.


Subject(s)
Biosensing Techniques , Microwaves , Culture Media , Escherichia coli
7.
IEEE Trans Biomed Circuits Syst ; 14(1): 2-11, 2020 02.
Article in English | MEDLINE | ID: mdl-31715571

ABSTRACT

Microwave resonator sensors are attractive for their contactless and label-free capability of monitoring bacterial growth in liquid media. This paper outlines a new label-free microwave biosensor based on a pair of planar split ring resonators for non-invasive monitoring of bacterial growth on a solid agar media. The sensor is comprised of two split ring resonators with slightly different resonant frequencies for differential operation. The transmission coefficient (S21) of the sensor is considered as the sensor's response with a designed and measured quality factor above 200 to ensure a high-resolution operation of the biosensor. Two resonant frequencies of 1.95 and 2.11 GHz represent the sensing signal and the reference signal, respectively. The developed sensor demonstrates high performance in monitoring the growth dynamics of Escherichia coli (E. coli) on Luria-Bertani (LB) agar with 4 mm thickness. The sensor's resonant amplitude response demonstrated 0.5 dB variation corresponding to the bacterial growth over 48 hours when bacteria were spread on LB agar starting with initial OD600 = 1.5. Moreover, 0.6 dB change in the sensor's response was observed over 96 hours of bacterial growth starting with an initial OD600 = 1.17 spotted on LB agar. The measured results fit well to the curves created using Richards' bacterial growth model, showing the strength of the sensor as a potential candidate for use in predictive food microbiology systems.


Subject(s)
Biosensing Techniques/instrumentation , Culture Media/chemistry , Escherichia coli/growth & development , Bacterial Load , Equipment Design , Microwaves
8.
Article in English | MEDLINE | ID: mdl-26221536

ABSTRACT

BACKGROUND: Perchlorate is an emerging water contaminant that disrupts normal functioning of human thyroid gland and poses serious threat to health, especially for pregnant women, fetus and children. RESULTS: High level of perchlorate contamination in fresh water sources at places nearby ammonium perchlorate (rocket fuel) handled in bulk is reported in this study. Of 160 ground water samples analyzed from 27 locations in the State Kerala, 58 % had perchlorate above detection limit (2 µg/L) and the highest concentration observed was 7270 µg/L at Ernakulam district, this value is ~480 times higher than USEPA drinking water equivalent level (15 µg/L). Perchlorate was detected in all surface water samples analyzed (n = 10) and the highest value observed was 355 µg/L in Periyar river (a major river in the State). The bottled drinking water (n = 5) tested were free of perchlorate. CONCLUSIONS: The present study underlines the need for frequent screening of water sources for perchlorate contamination around places the chemical is handled in bulk. It will help to avoid human exposure to high levels of perchlorate.

9.
Environ Technol ; 34(13-16): 2353-9, 2013.
Article in English | MEDLINE | ID: mdl-24350491

ABSTRACT

Kinetics of chlorite dismutase (CD), the terminal enzyme involved in the perchlorate (ClO4(-)) reduction pathway, in a ClO4(-)-degrading bioreactor are reported in this study. Enzyme activity was determined from dissolved oxygen released during disproportionation of chlorite (ClO2(-)). CD activity was in the range 29.8-36.4 U/mg dry weight sludge, and kinetic constants Vmax and K(m) of the enzyme were 37.83 U/mg dry weight and 0.28 mM, respectively. Among reactor operational conditions, enzyme activity was observed at pH 4.0-9.0, with an optimum at pH 6.0. Redox potential in the range -50 to +120mV and NaCl up to 3.5 g/L had no significant effect on CD activity. However, co-occurring pollutants such as ammonium at 10 ppm, nitrite at 50 ppm and EDTA at 100 microM reduced CD activity substantially. The present study highlights ideal bioreactor conditions to avoid ClO2(-) toxicity, while indicating the buffering potential of a mixed microbial system against inhibiting factors to maintain stable CD activity in bioreactors.


Subject(s)
Bioreactors , Oxidoreductases/chemistry , Oxidoreductases/metabolism , Perchlorates/chemistry , Perchlorates/metabolism , Sewage , Water Purification/methods , Ammonium Compounds/chemistry , Edetic Acid/chemistry , Hydrogen-Ion Concentration , Kinetics , Nitrites/chemistry , Perchlorates/analysis , Sodium Chloride/chemistry , Water Pollution, Chemical
SELECTION OF CITATIONS
SEARCH DETAIL
...