Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Retin Cases Brief Rep ; 10(4): 302-9, 2016.
Article in English | MEDLINE | ID: mdl-26735319

ABSTRACT

PURPOSE: To elucidate the location of pathological changes in multiple evanescent white dot syndrome (MEWDS) with the use of multimodal adaptive optics (AO) imaging. METHODS: A 5-year observational case study of a 24-year-old female with recurrent MEWDS. Full examination included history, Snellen chart visual acuity, pupil assessment, intraocular pressures, slit lamp evaluation, dilated fundoscopic exam, imaging with Fourier-domain optical coherence tomography (FD-OCT), blue-light fundus autofluorescence (FAF), fundus photography, fluorescein angiography, and adaptive-optics optical coherence tomography. RESULTS: Three distinct acute episodes of MEWDS occurred during the period of follow-up. Fourier-domain optical coherence tomography and adaptive-optics imaging showed disturbance in the photoreceptor outer segments (PR OS) in the posterior pole with each flare. The degree of disturbance at the photoreceptor level corresponded to size and extent of the visual field changes. All findings were transient with delineation of the photoreceptor recovery from the outer edges of the lesion inward. Hyperautofluorescence was seen during acute flares. Increase in choroidal thickness did occur with each active flare but resolved. CONCLUSION: Although changes in the choroid and RPE can be observed in MEWDS, Fourier-domain optical coherence tomography, and multimodal adaptive optics imaging localized the visually significant changes seen in this disease at the level of the photoreceptors. These transient retinal changes specifically occur at the level of the inner segment ellipsoid and OS/RPE line. En face optical coherence tomography imaging provides a detailed, yet noninvasive method for following the convalescence of MEWDS and provides insight into the structural and functional relationship of this transient inflammatory retinal disease.


Subject(s)
Multimodal Imaging , Optics and Photonics/methods , Retinal Diseases/diagnostic imaging , Tomography, Optical Coherence/methods , Female , Fluorescein Angiography , Humans , Microscopy, Confocal , Multimodal Imaging/methods , Retinal Diseases/physiopathology , Young Adult
2.
Invest Ophthalmol Vis Sci ; 55(10): 6459-66, 2014 Sep 16.
Article in English | MEDLINE | ID: mdl-25228539

ABSTRACT

PURPOSE: To characterize the in vivo three-dimensional (3D) lamina cribrosa (LC) microarchitecture of healthy eyes using adaptive optics spectral-domain optical coherence tomography (AO-SDOCT). METHODS: A multimodal retinal imaging system with a light source centered at 1050 nm and AO confocal scanning laser ophthalmoscopy was used in this study. One randomly selected eye from 18 healthy subjects was scanned in a 6° × 6° window centered on the LC. Subjects also underwent scanning with Cirrus HD-OCT. Lamina cribrosa microarchitecture was semiautomatically segmented and quantified for connective tissue volume fraction (CTVF), beam thickness, pore diameter, pore area, and pore aspect ratio. The LC was assessed in central and peripheral regions of equal areas and quadrants and with depth. A linear mixed effects model weighted by the fraction of visible LC was used to compare LC structure between regions. RESULTS: The nasal quadrant was excluded due to poor visualization. The central sector showed greater CTVF and thicker beams as compared to the periphery (P < 0.01). Both superior and inferior quadrants showed greater CTVF, pore diameter, and pore mean area than the temporal quadrant (P < 0.05). Depth analysis showed that the anterior and posterior aspects of the LC contained smaller pores with greater density and thinner beams as compared to the middle third (P < 0.05). The anterior third also showed a greater CTVF than the middle third (P < 0.05). CONCLUSIONS: In vivo analysis of healthy eyes using AO-SDOCT showed significant, albeit small, regional variation in LC microarchitecture by quadrant, radially, and with depth, which should be considered in further studies of the LC.


Subject(s)
Glaucoma/diagnosis , Imaging, Three-Dimensional , Optic Disk/pathology , Tomography, Optical Coherence/instrumentation , Adult , Equipment Design , Female , Glaucoma/physiopathology , Healthy Volunteers , Humans , Intraocular Pressure , Male , Optics and Photonics , Visual Fields
3.
Biomed Opt Express ; 5(4): 1114-23, 2014 Apr 01.
Article in English | MEDLINE | ID: mdl-24761293

ABSTRACT

We demonstrate the repeatability of lamina cribrosa (LC) microarchitecture for in vivo 3D optical coherence tomography (OCT) scans of healthy, glaucoma suspects, and glaucomatous eyes. Eyes underwent two scans using a prototype adaptive optics spectral domain OCT (AO-SDOCT) device from which LC microarchitecture was semi-automatically segmented. LC segmentations were used to quantify pore and beam structure through several global microarchitecture parameters. Repeatability of LC microarchitecture was assessed qualitatively and quantitatively by calculating parameter imprecision. For all but one parameters (pore volume) measurement imprecision was <4.7% of the mean value, indicating good measurement reproducibility. Imprecision ranged between 27.3% and 54.5% of the population standard deviation for each parameter, while there was not a significant effect on imprecision due to disease status, indicating utility in testing for LC structural trends.

4.
PLoS One ; 9(4): e95526, 2014.
Article in English | MEDLINE | ID: mdl-24747957

ABSTRACT

PURPOSE: To determine the reproducibility of automated segmentation of the three-dimensional (3D) lamina cribrosa (LC) microarchitecture scanned in-vivo using optical coherence tomography (OCT). METHODS: Thirty-nine eyes (8 healthy, 19 glaucoma suspects and 12 glaucoma) from 49 subjects were scanned twice using swept-source (SS-) OCT in a 3.5×3.5×3.64 mm (400×400×896 pixels) volume centered on the optic nerve head, with the focus readjusted after each scan. The LC was automatically segmented and analyzed for microarchitectural parameters, including pore diameter, pore diameter standard deviation (SD), pore aspect ratio, pore area, beam thickness, beam thickness SD, and beam thickness to pore diameter ratio. Reproducibility of the parameters was assessed by computing the imprecision of the parameters between the scans. RESULTS: The automated segmentation demonstrated excellent reproducibility. All LC microarchitecture parameters had an imprecision of less or equal to 4.2%. There was little variability in imprecision with respect to diagnostic category, although the method tends to show higher imprecision amongst healthy subjects. CONCLUSION: The proposed automated segmentation of the LC demonstrated high reproducibility for 3D LC parameters. This segmentation analysis tool will be useful for in-vivo studies of the LC.


Subject(s)
Imaging, Three-Dimensional , Optic Disk/anatomy & histology , Optic Disk/pathology , Tomography, Optical Coherence , Adult , Case-Control Studies , Glaucoma/diagnosis , Glaucoma/pathology , Humans , Image Processing, Computer-Assisted , Reproducibility of Results
5.
PLoS One ; 9(3): e90690, 2014.
Article in English | MEDLINE | ID: mdl-24595044

ABSTRACT

PURPOSE: To investigate gold nanorods (GNRs) as a contrast agent to enhance Doppler optical coherence tomography (OCT) imaging of the intrascleral aqueous humor outflow. METHODS: A serial dilution of GNRs was scanned with a spectral-domain OCT device (Bioptigen, Durham, NC) to visualize Doppler signal. Doppler measurements using GNRs were validated using a controlled flow system. To demonstrate an application of GNR enhanced Doppler, porcine eyes were perfused at constant pressure with mock aqueous alone or 1.0×10(12) GNR/mL mixed with mock aqueous. Twelve Doppler and volumetric SD-OCT scans were obtained from the limbus in a radial fashion incremented by 30°, forming a circular scan pattern. Volumetric flow was computed by integrating flow inside non-connected vessels throughout all 12 scans around the limbus. RESULTS: At the GNR concentration of 0.7×10(12) GNRs/mL, Doppler signal was present through the entire depth of the testing tube without substantial attenuation. A well-defined laminar flow profile was observed for Doppler images of GNRs flowing through the glass capillary tube. The Doppler OCT measured flow profile was not statistically different from the expected flow profile based upon an autoregressive moving average model, with an error of -0.025 to 0.037 mm/s (p = 0.6435). Cross-sectional slices demonstrated the ability to view anterior chamber outflow ex-vivo using GNR-enhanced Doppler OCT. Doppler volumetric flow measurements were comparable to flow recorded by the perfusion system. CONCLUSIONS: GNRs created a measureable Doppler signal within otherwise silent flow fields in OCT Doppler scans. Practical application of this technique was confirmed in a constant pressure ex-vivo aqueous humor outflow model in porcine eyes.


Subject(s)
Aqueous Humor/chemistry , Contrast Media/chemistry , Eye/ultrastructure , Gold/chemistry , Nanotubes/chemistry , Rheology/methods , Tomography, Optical Coherence/instrumentation , Animals , Doppler Effect , Swine , Tomography, Optical Coherence/methods
6.
Br J Ophthalmol ; 98 Suppl 2: ii10-4, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24590558

ABSTRACT

PURPOSE: To compare three methods of Schlemm's canal (SC) cross-sectional area (CSA) measurement. METHODS: Ten eyes (10 healthy volunteers) were imaged three times using spectral-domain optical coherence tomography (Cirrus HD-OCT, Zeiss, Dublin, California, USA). Aqueous outflow vascular structures and SC collector channel ostia were used as landmarks to identify a reference location within the limbus. SC CSA was assessed within a 1 mm segment (±15 frames of the reference, 31 frames in all) by three techniques. (1) Using a random number table, SC CSA in five random frames from the set of 31 surrounding the reference were measured and averaged. (2) The most easily visualised SC location (subjective) was measured, and (3) SC CSA was measured in all 31 consecutive B-scans, and averaged. (comprehensive average, gold standard). Subjective and random CSAs were compared with the comprehensive by general estimating equation modelling, and structural equation modelling quantified agreement. RESULTS: The average from five random locations (4175±1045 µm(2)) was not significantly different than that obtained from the gold standard comprehensive assessment (4064±1308 µm(2), p=0.6537). Subjectively located SC CSA (7614±2162 µm(2)) was significantly larger than the comprehensive gold standard SC CSA (p<0.0001). The average of five random frames produced significantly less bias than did subjective location, yielding a calibration line crossing the 'no-bias' line. DISCUSSION: Subjectively located SC CSA measurements produce high estimates of SC CSA. SC assessed by measuring five random locations estimate CSA was similar to the gold standard estimate.


Subject(s)
Anatomy, Cross-Sectional , Cornea/anatomy & histology , Limbus Corneae/anatomy & histology , Sclera/anatomy & histology , Adult , Aqueous Humor/physiology , Female , Healthy Volunteers , Humans , Male , Middle Aged , Tomography, Optical Coherence , Young Adult
7.
Invest Ophthalmol Vis Sci ; 55(3): 1805-9, 2014 Mar 25.
Article in English | MEDLINE | ID: mdl-24526436

ABSTRACT

PURPOSE: Previously, we demonstrated reduced Schlemm's canal cross-sectional area (SC-CSA) with increased perfusion pressure in a cadaveric flow model. The purpose of the present study was to determine the effect of acute IOP elevation on SC-CSA in living human eyes. METHODS: The temporal limbus of 27 eyes of 14 healthy subjects (10 male, 4 female, age 36 ± 13 years) was imaged by spectral-domain optical coherence tomography at baseline and with IOP elevation (ophthalmodynamometer set at 30-g force). Intraocular pressure was measured at baseline and with IOP elevation by Goldmann applanation tonometry. Vascular landmarks were used to identify corresponding locations in baseline and IOP elevation scan volumes. Schlemm's canal CSA at five locations within a 1-mm length of SC was measured in ImageJ as described previously. A linear mixed-effects model quantified the effect of IOP elevation on SC-CSA. RESULTS: The mean IOP increase was 189%, and the mean SC-CSA decrease was 32% (P < 0.001). The estimate (95% confidence interval) for SC-CSA response to IOP change was -66.6 (-80.6 to -52.7) µm(2)/mm Hg. CONCLUSIONS: Acute IOP elevation significantly reduces SC-CSA in healthy eyes. Acute dynamic response to IOP elevation may be a useful future characterization of ocular health in the management of glaucoma.


Subject(s)
Aqueous Humor/metabolism , Glaucoma/physiopathology , Intraocular Pressure/physiology , Limbus Corneae/physiopathology , Trabecular Meshwork/physiopathology , Adult , Female , Glaucoma/metabolism , Humans , Limbus Corneae/pathology , Male , Middle Aged , Sclera , Tomography, Optical Coherence , Tonometry, Ocular , Trabecular Meshwork/pathology , Young Adult
8.
Invest Ophthalmol Vis Sci ; 54(13): 8270-4, 2013 Dec 19.
Article in English | MEDLINE | ID: mdl-24302585

ABSTRACT

PURPOSE: The lamina cribrosa (LC) is a prime location of glaucomatous damage. The purpose of this study was to compare LC 3-dimensional micro-architecture between healthy and glaucomatous eyes in vivo by using optical coherence tomography (OCT). METHODS: Sixty-eight eyes (19 healthy and 49 glaucomatous) from 47 subjects were scanned in a 3.5 × 3.5 × 3.64-mm volume (400 × 400 × 896 pixels) at the optic nerve head by using swept-source OCT. The LC micro-architecture parameters were measured on the visible LC by an automated segmentation algorithm. The LC parameters were compared to diagnosis and visual field mean deviation (VF MD) by using a linear mixed effects model accounting for age. RESULTS: The average VF MD for the healthy and glaucomatous eyes was -0.50 ± 0.80 dB and -7.84 ± 8.75 dB, respectively. Beam thickness to pore diameter ratio (P = 0.04) and pore diameter standard deviation (P < 0.01) were increased in glaucomatous eyes. With worse MD, beam thickness to pore diameter ratio (P < 0.01), pore diameter standard deviation (P = 0.05), and beam thickness (P < 0.01) showed a statistically significant increase while pore diameter (P = 0.02) showed a significant decrease. There were no significant interactions between any of the parameters and age (all P > 0.05). CONCLUSIONS: Glaucomatous micro-architecture changes in the LC, detected by OCT analysis, reflect beams remodeling and axonal loss leading to reduction in pore size and increased pore size variability.


Subject(s)
Glaucoma, Open-Angle/diagnosis , Optic Disk/anatomy & histology , Optic Disk/pathology , Optic Nerve Diseases/diagnosis , Tomography, Optical Coherence/methods , Adult , Aged , Humans , Imaging, Three-Dimensional , Intraocular Pressure , Nerve Fibers/pathology , Retinal Ganglion Cells/pathology , Vision Disorders/diagnosis , Visual Field Tests , Visual Fields
9.
Biomed Opt Express ; 4(11): 2596-608, 2013.
Article in English | MEDLINE | ID: mdl-24298418

ABSTRACT

We demonstrate an automated segmentation method for in-vivo 3D optical coherence tomography (OCT) imaging of the lamina cribrosa (LC). Manual segmentations of coronal slices of the LC were used as a gold standard in parameter selection and evaluation of the automated technique. The method was validated using two prototype OCT devices; each had a subject cohort including both healthy and glaucomatous eyes. Automated segmentation of in-vivo 3D LC OCT microstructure performed comparably to manual segmentation and is useful for investigative research and in clinical quantification of the LC.

10.
PLoS One ; 8(2): e55476, 2013.
Article in English | MEDLINE | ID: mdl-23408988

ABSTRACT

PURPOSE: To develop a new three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) data analysis method using a machine learning technique based on variable-size super pixel segmentation that efficiently utilizes full 3D dataset to improve the discrimination between early glaucomatous and healthy eyes. METHODS: 192 eyes of 96 subjects (44 healthy, 59 glaucoma suspect and 89 glaucomatous eyes) were scanned with SD-OCT. Each SD-OCT cube dataset was first converted into 2D feature map based on retinal nerve fiber layer (RNFL) segmentation and then divided into various number of super pixels. Unlike the conventional super pixel having a fixed number of points, this newly developed variable-size super pixel is defined as a cluster of homogeneous adjacent pixels with variable size, shape and number. Features of super pixel map were extracted and used as inputs to machine classifier (LogitBoost adaptive boosting) to automatically identify diseased eyes. For discriminating performance assessment, area under the curve (AUC) of the receiver operating characteristics of the machine classifier outputs were compared with the conventional circumpapillary RNFL (cpRNFL) thickness measurements. RESULTS: The super pixel analysis showed statistically significantly higher AUC than the cpRNFL (0.855 vs. 0.707, respectively, p = 0.031, Jackknife test) when glaucoma suspects were discriminated from healthy, while no significant difference was found when confirmed glaucoma eyes were discriminated from healthy eyes. CONCLUSIONS: A novel 3D OCT analysis technique performed at least as well as the cpRNFL in glaucoma discrimination and even better at glaucoma suspect discrimination. This new method has the potential to improve early detection of glaucomatous damage.


Subject(s)
Glaucoma/diagnosis , Tomography, Optical Coherence/methods , Case-Control Studies , Humans
11.
Optom Vis Sci ; 89(5): E543-53, 2012 May.
Article in English | MEDLINE | ID: mdl-22488266

ABSTRACT

The broadening frontier of technology used in ocular imaging is continuously affecting the landscape of clinical eye care. With each wave of enhanced imaging modalities, the field faces the difficulties of optimally incorporating these devices into the clinic. Ocular imaging devices have been widely incorporated into clinical management after their diagnostic capabilities have been documented in a wide range of ocular disease. In this review, we are presenting the main commercially available devices for imaging of the posterior segment of the eye.


Subject(s)
Diagnostic Imaging/methods , Diagnostic Techniques, Ophthalmological/instrumentation , Eye Diseases/diagnosis , Equipment Design , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...