Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Shokuhin Eiseigaku Zasshi ; 64(4): 154-160, 2023.
Article in Japanese | MEDLINE | ID: mdl-37673605

ABSTRACT

An inter-laboratory study involving 24 laboratories was conducted to validate the modified analytical method for the migration solution of heptane for the determination of bisphenol A migrating from polycarbonate food processing materials. In this study, two concentrations of samples were blindly coded. Each laboratory determined the analyte (bisphenol A, phenol and p-tert-butylphenol) concentration in each sample according to the established protocol. The obtained values were analyzed statistically using internationally accepted guidelines. Horwitz ratios were calculated based on the reproducibility relative standard deviation (RSDR), which was estimated from the inter-laboratory study, and predicted RSDR, which was calculated using the Horwitz/Thompson equation. Horwitz ratios of the two samples ranged from 0.15 to 0.37 for the three compounds, meeting the performance criteria of less than 2 set by the Codex Alimentarius for analytical method approval. These results showed that this modified analytical method shows good performance as an analytical method for the migration solution of heptane.


Subject(s)
Heptanes , Phenols , Reproducibility of Results
2.
Shokuhin Eiseigaku Zasshi ; 63(2): 97-103, 2022.
Article in Japanese | MEDLINE | ID: mdl-35650035

ABSTRACT

We modified a method for determining methanol content in detergents used in kitchens. Furthermore, an inter-laboratory study was conducted in 10 laboratories to validate the modified method. In this study, two concentrations of samples were blindly coded. Each laboratory determined the methanol content in each sample according to a protocol. The determined values were statistically analyzed according to an international harmonized guideline. HorRat values were calculated based on the reproducibility relative standard deviation (RSDR) which was estimated from the interlaboratory study, and predicted RSDR calculated from the Horwitz/Thompson equation. The HorRat values of the two samples were 0.8 and 1.8, meeting the performance criteria of less than 2 set by the Codex Alimentarius for analytical method approval. These results confirm that this modified analytical method shows good performance as an analytical method for determining methanol content in kitchen detergents.


Subject(s)
Detergents , Methanol , Laboratories , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...