Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Spectrosc ; 76(12): 1482-1493, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36197444

ABSTRACT

Circular dichroism (CD) spectroscopy is a widely used technique for assessing the higher-order structure (HOS) of biopharmaceuticals, including antibody drugs. Since the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use established quality control guidelines, objective evaluation of spectral similarity has been required in order to assess structural comparability. Several spectral distance quantification methods and weighting functions to increase sensitivity have been proposed, but not many reports have compared their performance for CD spectra. We constructed comparison sets that combine actual spectra and simulated noise and performed a comprehensive performance evaluation of each spectral distance calculation method and weighting function under conditions that consider spectral noise and fluctuations from pipetting errors. The results showed that using the Euclidean distance or Manhattan distance with Savitzky-Golay noise reduction is effective for spectral distance assessment. For the weighting function, it is preferable to combine the spectral intensity weighting function and the noise weighting function. In addition, the introduction of the external stimulus weighting function should be considered to improve the sensitivity. It is crucial to select the weighting function based on the balance between spectral changes and noise distributions for robust, sensitive antibody HOS similarity assessment.

2.
Front Chem ; 8: 527, 2020.
Article in English | MEDLINE | ID: mdl-32656184

ABSTRACT

Circularly polarized luminescence (CPL) spectroscopy measures the difference in luminescence intensity between left- and right-circularly polarized light, and is often used to analyze the structure of chiral molecules in their excited state. Recently, it has found an increasing range of applications in the analysis of molecules that emit circularly polarized light and can be employed in 3D displays. Thus, the number of articles focusing on CPL spectroscopy has increased dramatically. However, since the luminescence dissymmetry factor (g lum) for organic compounds is generally <|0.01|, CPL spectrometers must offer high sensitivity and produce spectra that are artifact-free for chiral molecules. Until now, the principal targets of CPL measurements have been solution samples. However, for practical device applications, it is also necessary to be able to measure the CPL spectra of solid-state samples. In addition, since electronic devices often operate at high temperatures, it is important to evaluate the thermal dependence of the CPL characteristics. Moreover, in the measurement of solid-state samples, the degree of anisotropy of the samples must be evaluated, because a large degree of anisotropy can cause artifacts. Therefore, we describe methods to evaluate the degree of anisotropy of solid-state samples and their high-temperature applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...