1.
Heliyon ; 9(4): e14790, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37089380

ABSTRACT

Aim: To explore the feasibility and accuracy of virtual reality (VR) derived from cardiac computed angiography (CCTA) data to predict left atrial appendage occlusion (LAAO) device size. Method: Retrospective data of patients who underwent LAAO according to clinical indication were reviewed; all patients underwent a pre-procedural CCTA. Measurements of the left atrial appendage (LAA) orifice diameters by CCTA, VR, and transesophageal echocardiography (TEE) (acquired during the procedure) were compared to the implanted device size. The LAA perimeter was calculated using the Ramanujan approximation. Statistical analyses included Lin's Concordance Correlation Coefficient (ρ c ), the mean difference, and the mean square error (MSE). Results: The sample was composed of 20 patients (mean age 75.7 ± 7.5 years, 60% males) who underwent successful LAAO insertion (ACP™ N = 8, Watchman™ N = 12). The CCTA, VR, and TEE maximal diameter ρ c was 0.52, 0.78 and 0.60, respectively with mean differences of +0.92 ± 4.0 mm, -1.12 ± 2.3 mm, and -3.45 ± 2.69 mm, respectively. The CCTA, VR, and TEE perimeter calculations ρ c were 0.49, 0.54, and 0.39 respectively with mean differences of +4.69 ± 11.5 mm, -9.88 ± 8.0 mm, and -16.79 ± 7.8 respectively. Discussion: A VR visualization of the LAA ostium in different perspectives allows for a better understanding of its funnel-shaped structure. VR measurement of the maximal ostium diameter had the strongest correlation with the diameter of the inserted device. VR may thus provide new imaging possibilities for the evaluation of complex pre-procedural structures such as the LAA.

2.
Therap Adv Gastroenterol ; 16: 17562848231160625, 2023.
Article in English | MEDLINE | ID: mdl-36968619

ABSTRACT

Objectives: Three-dimensional virtual reality (3D VR) permits precise reconstruction of computed tomography (CT) images, and these allow precise measurements of colonic anatomical parameters. Colonoscopy proves challenging in a subset of patients, and thus CT colonoscopy (CTC) is often required to visualize the entire colon. The aim of the study was to determine whether 3D reconstructions of the colon could help identify and quantify the key anatomical features leading to colonoscopy failure. Design: Retrospective observational study. Methods: Using 3D VR technology, we reconstructed and compared the length of various colonic segments and number of bends and colonic width in 10 cases of CTC in technically failed prior colonoscopies to 10 cases of CTC performed for non-technically failure indications. Results: We found significant elongation of the sigmoid colon (71 ± 23 cm versus 35 ± 9; p = 0.01) and of pancolonic length (216 ± 38 cm versus 158 ± 20 cm; p = 0.001) in cases of technically failed colonoscopy. There was also a significant increase in the number of colonic angles (17.7 ± 3.2 versus 12.7 ± 2.4; p = 0.008) in failed colonoscopy cases. Conclusion: Increased sigmoid and pancolonic length and more colonic bends are novel factors associated with technical failure of colonoscopy.

3.
Heliyon ; 8(11): e11250, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36387466

ABSTRACT

Introduction: Simpson's rule is generally used to estimate cardiac volumes. By contrast, modern methods such as Virtual Reality (VR) utilize mesh modeling to present the object's surface spatial structure, thus enabling intricate volumetric calculations. In this study, two types of semiautomated VR models for cardiac volumetric analysis were compared to the standard Philips dedicated cardiac imaging platform (PDP) which is based on Simpson's rule calculations. Methods: This retrospective report examined the cardiac computed tomography angiography (CCTA) of twenty patients with atrial fibrillation obtained prior to a left atrial appendage occlusion procedure. We employed two VR models to evaluate each CCTA and compared them to the PDP: a VR model with Philips-similar segmentations (VR-PS) that included the trabeculae and the papillary muscles within the luminal volume, and a VR model that only included the inner blood pool (VR-IBP). Results: Comparison of the VR-PS and the PDP left ventricle (LV) volumes demonstrated excellent correlation with a ρ c of 0.983 (95% CI 0.96, 0.99), and a small mean difference and range. The calculated volumes of the right ventricle (RV) had a somewhat lower correlation of 0.89 (95% CI 0.781, 0.95), a small mean difference, and a broader range. The VR-IBP chamber size estimations were significantly smaller than the estimates based on the PDP. Discussion: Simpson's rule and polygon summation algorithms produce similar results in normal morphological LVs. However, this correlation failed to emerge when applied to RVs and irregular chambers. Conclusions: The findings suggest that the polygon summation method is preferable for RV and irregular LV volume and function calculations.