Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Physiol (1985) ; 137(1): 32-41, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38813612

ABSTRACT

Blood volume shifts during postural adjustment lead to irregular distension of the internal jugular vein (IJV). In microgravity, distension may contribute to flow stasis and thromboembolism, though the regional implications and associated risk remain unexplored. We characterized regional differences in IJV volume distension and flow complexity during progressive head-down tilt (HDT) (0°, -6°, -15°, -30°) using conventional ultrasound and vector flow imaging. We also evaluated low-pressure thigh cuffs (40 mmHg) as a fluid shifting countermeasure during -6° HDT. Total IJV volume expanded 139 ± 95% from supine position (4.6 ± 2.7 mL) to -30° HDT (10.3 ± 5.0 mL). Blood flow profiles had greater vector uniformity at the cranial IJV region (P < 0.01) and became more dispersed with increasing tilt (P < 0.01). Qualitatively, flow was more uniform throughout the IJV during its early flow cycle phase and more disorganized during late flow phase. This disorganized flow was accentuated closer to the vessel wall, near the caudal region, and during greater HDT. Low-pressure thigh cuffs during -6° HDT decreased IJV volume at the cranial region (-12 ± 15%; P < 0.01) but not the caudal region (P = 0.20), although flow uniformity was unchanged (both regions, P > 0.25). We describe a distensible IJV accommodating large volume shifts along its length. Prominent flow dispersion was primarily found at the caudal region, suggesting multidirectional blood flow. Thigh cuffs appear effective for decreasing IJV volume but effects on flow complexity are minor. Flow complexity along the vessel length is likely related to IJV distension during chronic volume shifting and may be a precipitating factor for flow stasis and future thromboembolism risk.NEW & NOTEWORTHY The internal jugular vein (IJV) facilitates cerebral outflow and is sensitive to volume shifts. Concerns about IJV expansion and fluid flow behavior in astronauts have surfaced following thromboembolism reports. Our study explored regional volume distension and blood flow complexity in the IJV during progressive volume shifting. We observed stepwise volume distension and increasing flow dispersion with head-down tilting across all regions. Flow dispersion may pose a risk of future thromboembolism during prolonged volume shifts.


Subject(s)
Head-Down Tilt , Jugular Veins , Humans , Jugular Veins/physiology , Jugular Veins/diagnostic imaging , Male , Head-Down Tilt/physiology , Adult , Female , Blood Volume/physiology , Young Adult , Regional Blood Flow/physiology , Blood Flow Velocity/physiology , Ultrasonography/methods
2.
Med Phys ; 51(1): 428-438, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37983613

ABSTRACT

BACKGROUND: Quantitative and comprehensive visualization of urinary flow dynamics in the urethra is crucial for investigating patient-specific mechanisms of lower urinary tract symptoms (LUTS). Although some methods can evaluate the global properties of the urethra, it is critical to assess the local information, such as the location of the responsible lesion and its interactions with urinary flow in relation to LUTS. This approach is vital for enhancing personalized and focal treatments. However, there is a lack of such diagnostic tools that can directly observe how the urethral shape and motion impact urinary flow in the urethra. PURPOSE: This study aimed to develop a novel transrectal ultrasound imaging modality based on the contrast-enhanced urodynamic vector projectile imaging (CE-UroVPI) framework and validate its clinical applicability for visualizing time-resolved flow dynamics in the urethra. METHODS: A new CE-UroVPI system was developed using a research-purpose ultrasound platform and a custom transrectal linear probe, and an imaging protocol for acquiring urodynamic echo data in male patients was designed. Thirty-four male patients with LUTS participated in this study. CE-UroVPI was performed to acquire ultrasound echo signals from the participant's urethra and urinary flow at various voiding phases (initiation, maintenance, and terminal). The ultrasound datasets were processed with custom software to visualize urinary flow dynamics and urethra tissue deformation. RESULTS: The transrectal CE-UroVPI system successfully visualized the time-resolved multidirectional urinary flow dynamics in the prostatic urethra during the initiation, maintenance, and terminal phases of voiding in 17 patients at a frame rate of 1250 fps. The maximum flow speed measured in this study was 2.5 m/s. In addition, when the urethra had an obstruction or an irregular partial deformation, the devised imaging modality visualized complex flow patterns, such as vortices and flow jets around the lesion. CONCLUSIONS: Our study findings demonstrate that the transrectal CE-UroVPI system developed in this study can effectively image fluid-structural interactions in the urethra. This new diagnostic technology has the potential to facilitate quantitative and precise assessments of urethral voiding functions and aid in the improvement of focal and effective treatments for patients with LUTS.


Subject(s)
Prostate , Urethra , Humans , Male , Urethra/diagnostic imaging , Urethra/pathology , Pilot Projects , Ultrasonography , Prostate/diagnostic imaging , Treatment Outcome
3.
Article in English | MEDLINE | ID: mdl-37549086

ABSTRACT

Vector Doppler is well regarded as a potential way of deriving flow vectors to intuitively visualize complex flow profiles, especially when it is implemented at high frame rates. However, this technique's performance is known to suffer from aliasing artifacts. There is a dire need to devise real-time dealiasing solutions for vector Doppler. In this article, we present a new methodological framework for achieving aliasing-resistant flow vector estimation at real-time throughput from precalculated Doppler frequencies. Our framework comprises a series of compute kernels that have synergized: 1) an extended least squares vector Doppler (ELS-VD) algorithm; 2) single-instruction, multiple-thread (SIMT) processing principles; and 3) implementation on a graphical processing unit (GPU). Results show that this new framework, when executed on an RTX-2080 GPU, can effectively generate aliasing-free flow vector maps using high-frame-rate imaging datasets acquired from multiple transmit-receive angle pairs in a carotid phantom imaging scenario. Over the entire cardiac cycle, the frame processing time for aliasing-resistant vector estimation was measured to be less than 16 ms, which corresponds to a minimum processing throughput of 62.5 frames/s. In a human femoral bifurcation imaging trial with fast flow (150 cm/s), our framework was found to be effective in resolving two-cycle aliasing artifacts at a minimum throughput of 53 frames/s. The framework's processing throughput was generally in the real-time range for practical combinations of ELS-VD algorithmic parameters. Overall, this work represents the first demonstration of real-time, GPU-based aliasing-resistant vector flow imaging using vector Doppler estimation principles.


Subject(s)
Ultrasonography, Doppler , Humans , Blood Flow Velocity , Ultrasonography, Doppler/methods , Ultrasonography/methods , Phantoms, Imaging , Least-Squares Analysis
4.
Ultrasonics ; 134: 107050, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37300906

ABSTRACT

Vector flow imaging is a diagnostic ultrasound modality that is suited for the visualization of complex blood flow dynamics. One popular way of realizing vector flow imaging at high frame rates over 1000 fps is to apply multi-angle vector Doppler estimation principles in conjunction with plane wave pulse-echo sensing. However, this approach is susceptible to flow vector estimation errors attributed to Doppler aliasing, which is prone to arise when a low pulse repetition frequency (PRF) is inevitably used due to the need for finer velocity resolution or because of hardware constraints. Existing dealiasing solutions tailored for vector Doppler may have high computational demand that makes them unfeasible for practical applications. In this paper, we present the use of deep learning and graphical processing unit (GPU) computing principles to devise a fast vector Doppler estimation framework that is resilient against aliasing artifacts. Our new framework works by using a convolutional neural network (CNN) to detect aliased regions in vector Doppler images and subsequently applying an aliasing correction algorithm only at these affected regions. The framework's CNN was trained using 15,000 in vivo vector Doppler frames acquired from the femoral and carotid arteries, including healthy and diseased conditions. Results show that our framework can perform aliasing segmentation with an average precision of 90 % and can render aliasing-free vector flow maps with real-time processing throughputs (25-100 fps). Overall, our new framework can improve the visualization quality of vector Doppler imaging in real-time.


Subject(s)
Deep Learning , Phantoms, Imaging , Blood Flow Velocity/physiology , Ultrasonography, Doppler/methods , Carotid Arteries/diagnostic imaging
5.
Article in English | MEDLINE | ID: mdl-32746180

ABSTRACT

Despite being used clinically as a noninvasive flow visualization tool, color flow imaging (CFI) is known to be prone to aliasing artifacts that arise due to fast blood flow beyond the detectable limit. From a visualization standpoint, these aliasing artifacts obscure proper interpretation of flow patterns in the image view. Current solutions for resolving aliasing artifacts are typically not robust against issues such as double aliasing. In this article, we present a new dealiasing technique based on deep learning principles to resolve CFI aliasing artifacts that arise from single- and double-aliasing scenarios. It works by first using two convolutional neural networks (CNNs) to identify and segment CFI pixel positions with aliasing artifacts, and then it performs phase unwrapping at these aliased pixel positions. The CNN for aliasing identification was devised as a U-net architecture, and it was trained with in vivo CFI frames acquired from the femoral bifurcation that had known presence of single- and double-aliasing artifacts. Results show that the segmentation of aliased CFI pixels was achieved successfully with intersection over union approaching 90%. After resolving these artifacts, the dealiased CFI frames consistently rendered the femoral bifurcation's triphasic flow dynamics over a cardiac cycle. For dealiased CFI pixels, their root-mean-squared difference was 2.51% or less compared with manual dealiasing. Overall, the proposed dealiasing framework can extend the maximum flow detection limit by fivefold, thereby improving CFI's flow visualization performance.


Subject(s)
Deep Learning , Image Processing, Computer-Assisted/methods , Ultrasonography, Doppler, Color/methods , Artifacts , Carotid Arteries/diagnostic imaging , Humans , Phantoms, Imaging
6.
Urology ; 140: 171-177, 2020 06.
Article in English | MEDLINE | ID: mdl-32197985

ABSTRACT

OBJECTIVE: To devise a new urodynamic imaging framework that can provide time-resolved visualization of urinary flow and urethral deformation during the initiation phase of voiding. MATERIALS AND METHODS: Contrast-enhanced urodynamic vector projectile imaging (CE-UroVPI) was devised using the principles of high-frame rate ultrasound, microbubble contrast agents, and flow vector mapping. CE-UroVPI was implemented using a research-purpose ultrasound scanner (5 MHz frequency) and commercial contrast agents (USphere Prime). The performance of CE-UroVPI was evaluated using 2 custom-designed deformable urethra phantoms - a healthy model and a diseased model with benign prostatic hyperplasia (BPH) - that respectively simulate urodynamics in the urinary tract with and without mechanical obstruction. The corresponding spatiotemporal urodynamics were investigated and analyzed. RESULTS: Using a frame rate of 1,250 fps that corresponds to 0.8 ms time resolution, CE-UroVPI effectively depicted the transient urodynamic events during the initiation phase of voiding. Anomalous spatiotemporal characteristics were observed in the urodynamics of the BPH-obstructed urethra. Specifically, upstream from the obstruction site, a transient surge in flow speed was observed in the first 100 ms of voiding. Also, downstream from the obstruction site, complex urodnyamics had emerged in the forms of flow jet and vortices. These anomalies were not found in the healthy urethra. CONCLUSION: CE-UroVPI is the first imaging framework that can visualize complex urodynamics over an entire voiding episode including its initiation phase. This new tool may be used to potentially gain new insight into the causal relationships between urethral morphokinetic factors and lower urinary tract symptoms.


Subject(s)
Contrast Media/pharmacology , Lower Urinary Tract Symptoms , Phantoms, Imaging , Ultrasonography , Urethra/diagnostic imaging , Urodynamics , Humans , Lower Urinary Tract Symptoms/diagnosis , Lower Urinary Tract Symptoms/physiopathology , Microbubbles , Spatio-Temporal Analysis , Ultrasonography/instrumentation , Ultrasonography/methods , Urethra/abnormalities , Urethra/pathology , Urethra/physiopathology , Urination
7.
Med Phys ; 46(7): 3034-3043, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31049993

ABSTRACT

PURPOSE: Assessment of urethral dynamics is clinically regarded to be important in analyzing the functional impact of pathological features like urethral obstruction, albeit it is difficult to perform directly in vivo. To facilitate such an assessment, urethra phantoms may serve well as investigative tools by reconstructing urethral dynamics based on anthropomorphic factors. Here, our aim is to design a new class of anatomically realistic, deformable urethra phantoms that can simulate the geometric, mechanical, and hydrodynamic characteristics of the male prostatic urethra. METHODS: A new lost-core tube casting protocol was devised. It first involved the drafting of urethra geometry in computer-aided design software. Next, 3D printing was used to fabricate the urethra geometry and an outer mold. These parts were then used to cast a urinary tract using a polyvinyl alcohol (PVA)-based material (with 26.6 ± 4.0 kPa Young's elastic modulus). After forming a surrounding tissue-mimicking slab using an agar-gelatin mixture (with 17.4 ± 3.4 kPa Young's modulus), the completed urethra phantom was connected to a flow circuit that simulates voiding. To assess the fabricated phantoms' morphology, ultrasound imaging was performed over different planes. Also, color Doppler imaging was performed to visualize the flow profile within the urinary tract. RESULTS: Deformable phantoms were devised for the normal urethra and a diseased urethra with obstruction due to benign prostatic hyperplasia (BPH). During voiding, the short-axis lumen diameter at the verumontanum of the BPH-featured phantom (0.91 ± 0.08 mm) was significantly smaller than that for the normal phantom (2.49 ± 0.20 mm). Also, the maximum flow velocity of the BPH-featured phantom (59.3 ± 5.8 cm/s; without Doppler angle correction) was found to be higher than that of the normal phantom (22.7 ± 9.0 cm/s). CONCLUSION: The fabricated phantoms were effective in simulating urethra deformation resulting from urine passage during voiding. They can be used for mechanistic studies of urethral dynamics and for the testing of urodynamic diagnostic techniques in urology.


Subject(s)
Phantoms, Imaging , Prostate/physiology , Urodynamics , Biomechanical Phenomena , Humans , Male , Prostate/diagnostic imaging , Prostate/physiopathology , Prostatic Hyperplasia/diagnostic imaging , Prostatic Hyperplasia/pathology , Prostatic Hyperplasia/physiopathology , Ultrasonography , Urethra/diagnostic imaging , Urethra/pathology , Urethra/physiopathology , Urinary Tract/anatomy & histology , Urinary Tract/diagnostic imaging , Urinary Tract/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...