Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-26322587

ABSTRACT

An enantioselective high performance liquid chromatography method has been developed and validated by evaluating the suitability of newly introduced immobilized polysaccharide chiral stationary phases, the effect of different organic modifiers and temperature including the entropy and enthalpy on resolution of the (R,S)-(-) & (S,R)-(+) emtricitabine enantiomers on rat dried blood spots. Both the enantiomers were extracted from dried blood spots using ethanol: methanol (80:20 v/v) mixture and separated on an immobilized amylose tris-(3,5-dimethyl phenyl carbamate) chiral stationary phase using n-hexane:ethanol (65:35 v/v) as a mobile phase at a flow rate of 0.8mL/min. The detection was carried out at 280nm using photo diode array detector connected to a polarimeter in series to determine their order of eluton. The method was validated with respect to limits of detection and quantification, linearity, accuracy and precision. The calibration curves were linear over the concentration range of 0.5-500µg/mL for both enantiomers and the correlation coefficient (r(2)) was >0.998. The overall recovery of (R,S)- & (S,R)-enantiomers of emtricitabin from DBS were 90.4 and 90.6%, respectively. The limits of detection and quantification of enantiomers were 0.26, 0.30 and 0.85, 0.92µg/mL for (R,S)- and (S,R)-emtricitabin enantiomers, respectively. The assay was specific and precise (RSD <10%). The stability of emtricitabin was also performed and the results were found to be well within the limits. The effect of hematocrit on extraction of emtricitabin enantiomers from dried blood spots was evaluated and no interference from endogenous substances was observed.


Subject(s)
Amylose/chemistry , Emtricitabine/blood , Reverse Transcriptase Inhibitors/blood , Silicon Dioxide/chemistry , Animals , Chromatography, High Pressure Liquid , Limit of Detection , Rats , Rats, Wistar , Reproducibility of Results , Stereoisomerism
2.
Chirality ; 24(8): 652-60, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22615221

ABSTRACT

Liquid chromatographic separation of darunavir enantiomers on covalently bonded and physically adsorbed polysaccharide chiral stationary phases was studied at different temperatures. The separations were accomplished under normal-phase conditions by using different combinations of hexane, organic modifiers (2-propanol, 1-propanol and ethanol), and diethylamine as mobile phase solvents. The effect of organic modifiers and the column temperature on retention, separation, and resolution was investigated. The observed differences were explained in terms of the coated and immobilized nature of the two columns. Van't Hoff plots (ln k' vs. 1/T, ln α vs. 1/T) and apparent thermodynamic parameters were derived to understand the effect of temperature on separation.

SELECTION OF CITATIONS
SEARCH DETAIL
...