Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 438
Filter
1.
Artif Organs ; 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38825957

ABSTRACT

BACKGROUND: Hospital readmissions following left ventricular assist device (LVAD) remain a frequent comorbidity, associated with decreased quality of life and increased resources utilization. This study sought to determine causes, predictors, and impact on survival of hospitalizations during HeartMate 3 (HM3) support. METHODS: All patients implanted with HM3 between November 2014 to December 2019 at Columbia University Irving Medical Center were consecutively enrolled in the study. Demographics and clinical characteristics from the index admission and the first outpatient visit were collected and used to estimate 1-year and 900-day readmission-free survival and overall survival. Multivariable analysis was performed for subsequent readmissions. RESULTS: Of 182 patients who received a HM3 LVAD, 167 (92%) were discharged after index admission and experienced 407 unplanned readmissions over the median follow up of 727 (interquartile range (IQR): 410.5, 1124.5) days. One-year and 900-day mean cumulative number of all-cause unplanned readmissions was 0.43 (95%CI, 0.36, 0.51) and 1.13 (95%CI, 0.99, 1.29). The most frequent causes of rehospitalizations included major infections (29.3%), bleeding (13.2%), device-related (12.5%), volume overload (7.1%), and other (28%). One-year and 900-day survival free from all-cause readmission was 38% (95%CI, 31-46%) and 16.6% (95%CI, 10.3-24.4%). One-year and 900-day freedom from 2, 3, and ≥4 readmissions were 60.7%, 74%, 74.5% and 26.2%, 33.3%, 41.3%. One-year and 900-day survival were unaffected by the number of readmissions and remained >90%. Male sex, ischemic etiology, diabetes, lower serum creatinine, longer duration of index hospitalization, and a history of readmission between discharge and the first outpatient visit were associated with subsequent readmissions. CONCLUSIONS: Unplanned hospital readmissions after HM3 are common, with infections and bleeding accounting for the majority of readmissions. Irrespective of the number of readmissions, one-year survival remained unaffected.

2.
Article in English | MEDLINE | ID: mdl-38802043

ABSTRACT

OBJECTIVE: Our objective was to analyze the development of aortic insufficiency in patients who received central aortic valve repair when undergoing continuous-flow left ventricular assist device implantation. METHODS: We conducted a retrospective review of patients who underwent HeartMate II or 3 (Abbott Lab) implantation between 2004 and 2022. Ninety-four patients were excluded from analysis for history of aortic valve procedures, a bicuspid aortic valve, baseline trace aortic insufficiency, or other concomitant aortic valve procedure. Patients who had ≥ mild aortic insufficiency had concomitant aortic valve repair. Clinical characteristics, serial echocardiograms, and outcomes were determined. RESULTS: Of the 656 patients who underwent HeartMate II or 3 implantation, 105 patients (59 HeartMate II and 46 HeartMate 3) met study criteria. Median age was 68 years [60-74 years], 91.4% [n=96] were male, 54.4% [n=56] were white, and 68.6% [n=72] received support as destination therapy. Preoperative aortic insufficiency degree was 54.3% (n=57) mild, 23.8% (n=25) mild-to-moderate, 20.0% (n=21) moderate, 1.0% (n=1) moderate-to-severe, 1.0% (n=1) severe. In hospital mortality was 5.7% [n=6]. Freedom from ≥ moderate aortic insufficiency was 96.4% (95%CI: 92.5%-100%), 93.3% (95%CI: 87.6%-99.2%), and 91.0% (95%CI: 84.1%-98.5%) at 1-year, 2-year, and 3-year post-implantation, respectively. One HeartMate II patient experienced severe aortic insufficiency and was treated with a heart transplant. Three-year survival was 63.4% [95%CI: 52.9%-75.9%]. CONCLUSIONS: Central aortic valve repair may be an effective technique to mitigate aortic insufficiency in HeartMate II and 3. A larger cohort study with longer duration of follow up is warranted to further investigate the clinical impact.

3.
Circ Heart Fail ; 17(3): e011115, 2024 03.
Article in English | MEDLINE | ID: mdl-38456308

ABSTRACT

BACKGROUND: Although much attention has been paid to admission and transfer patterns for cardiogenic shock, contemporary data are lacking on decompensated heart failure (HF) admissions and transfers and the impact of advanced therapy centers (ATCs) on outcomes. METHODS: HF hospitalizations were obtained from the Nationwide Readmissions Database 2016 to 2019. Centers performing at least 1 heart transplant or left ventricular assist device were classified as ATCs. Patient characteristics, outcomes, and procedural volume were compared among 3 cohorts: admissions to non-ATCs, admissions to ATCs, and transfers to ATCs. A secondary analysis evaluated outcomes for severe HF hospitalizations (cardiogenic shock, cardiac arrest, and mechanical ventilation). Multivariable logistic regression was performed to adjust for the presence of HF decompensations and significant clinical variables during univariate analysis. RESULTS: A total of 2 331 690 hospitalizations (81.2%) were admissions to non-ATCs (94.5% of centers), 525 037 (18.3%) were admissions to ATCs (5.5% of centers), and 15 541 (0.5%) were transferred to ATCs. Patients treated at ATCs (especially those transferred) had higher rates of HF decompensations, procedural frequency, lengths of stay, and costs. Unadjusted mortality was 2.6% at non-ATCs and was higher at ATCs, both for directly admitted (2.9%, P<0.001) and transferred (11.2%, P<0.001) patients. However, multivariable-adjusted mortality was significantly lower at ATCs, both for directly admitted (odds ratio, 0.82 [95% CI, 0.78-0.87]; P<0.001) and transferred (odds ratio, 0.66 [95% CI, 0.57-0.78]; P<0.001) patients. For severe HF admissions, unadjusted mortality was 37.2% at non-ATCs and was lower at ATCs, both for directly admitted (25.3%, P<0.001) and transferred (25.2%, P<0.001) patients, with similarly lower multivariable-adjusted mortality. CONCLUSIONS: Patients with HF treated at ATCs were sicker but associated with higher procedural volume and lower adjusted mortality.


Subject(s)
Heart Arrest , Heart Failure , Humans , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Shock, Cardiogenic/complications , Hospitalization , Hospital Mortality
4.
Clin Transplant ; 38(3): e15251, 2024 03.
Article in English | MEDLINE | ID: mdl-38504576

ABSTRACT

BACKGROUND: Belatacept (BTC), a fusion protein, selectively inhibits T-cell co-stimulation by binding to the CD80 and CD86 receptors on antigen-presenting cells (APCs) and has been used as immunosuppression in adult renal transplant recipients. However, data regarding its use in heart transplant (HT) recipients are limited. This retrospective cohort study aimed to delineate BTC's application in HT, focusing on efficacy, safety, and associated complications at a high-volume HT center. METHODS: A retrospective cohort study was conducted of patients who underwent HT between January 2017 and December 2021 and subsequently received BTC as part of their immunosuppressive regimen. Twenty-one HT recipients were identified. Baseline characteristics, history of rejection, and indication for BTC use were collected. Outcomes included renal function, graft function, allograft rejection and mortality. Follow-up data were collected through December 2023. RESULTS: Among 776 patients monitored from January 2017 to December 2021 21 (2.7%) received BTC treatment. Average age at transplantation was 53 years (± 12 years), and 38% were women. BTC administration began, on average, 689 [483, 1830] days post-HT. The primary indications for BTC were elevated pre-formed donor-specific antibodies in highly sensitized patients (66.6%) and renal sparing (23.8%), in conjunction with reduced calcineurin inhibitor dosage. Only one (4.8%) patient encountered rejection within a year of starting BTC. Graft function by echocardiography remained stable at 6 and 12 months posttreatment. An improvement was observed in serum creatinine levels (76.2% of patients), decreasing from a median of 1.58 to 1.45 (IQR [1.0-2.1] to [1.1-1.9]) over 12 months (p = .054). eGFR improved at 3 and 6 months compared with 3 months pre- BTC levels; however, this was not statistically significant (p = .24). Treatment discontinuation occurred in seven patients (33.3%) of whom four (19%) were switched back to full dose CNI. Infections occurred in 11 patients (52.4%), leading to BTC discontinuation in 4 patients (19%). CONCLUSION: In this cohort, BTC therapy was used as alternative immunosuppression for management of highly sensitized patients or for renal sparing. BTC therapy when combined with CNI dose reduction resulted in stabilization in renal function as measured through renal surrogate markers, which did not, however, reach statistical significance. Patients on BTC maintained a low rejection rate and preserved graft function. Infections were common during BTC therapy and were associated with medication pause/discontinuation in 19% of patients. Further randomized studies are needed to assess the efficacy and safety of BTC in HT recipients.


Subject(s)
Heart Transplantation , Kidney Transplantation , Adult , Humans , Female , Middle Aged , Male , Abatacept , Retrospective Studies , Kidney Transplantation/adverse effects , Immunosuppressive Agents , Calcineurin Inhibitors/therapeutic use , T-Lymphocytes , Graft Rejection/drug therapy , Graft Rejection/etiology , Transplant Recipients , Graft Survival
5.
Article in English | MEDLINE | ID: mdl-38367698

ABSTRACT

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

6.
ASAIO J ; 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38373176

ABSTRACT

In patients supported by the HeartMate 3 left ventricular assist device (HM3 LVAD), pump speed adjustments may improve hemodynamics. We investigated the hemodynamic implications of speed adjustments in HM3 recipients undergoing hemodynamic ramp tests. Clinically stable HM3 recipients who underwent routine invasive hemodynamic ramp tests between 2015 and 2022 at our center were included. Filling pressure optimization, defined as central venous pressure (CVP) <12 mm Hg and pulmonary capillary wedge pressure (PCWP) <18 mm Hg, was assessed at baseline and final pump speeds. Patients with optimized pressures were compared to nonoptimized patients. Overall 60 HM3 recipients with a median age of 62 years (56, 71) and time from LVAD implantation of 187 days (124, 476) were included. Optimized filling pressures were found in 35 patients (58%) at baseline speed. Speed was adjusted in 84% of the nonoptimized patients. Consequently, 39 patients (65%) had optimized pressures at final speed. There were no significant differences in hemodynamic findings between baseline and final speeds (p > 0.05 for all). Six and 12 month readmission-free rates were higher in optimized compared with nonoptimized patients (p = 0.03 for both), predominantly due to lower cardiac readmission-free rates (p = 0.052). In stable outpatients supported with HM3 who underwent routine ramp tests, optimized hemodynamics were achieved in only 2 of 3 of the patients. Patients with optimized pressures had lower all-cause readmission rates, primarily driven by fewer cardiac-related hospitalizations.

7.
J Am Heart Assoc ; 13(3): e032607, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38240236

ABSTRACT

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used for patients with cardiogenic shock. Although Impella or intra-aortic balloon pump (IABP) is frequently used for left ventricular unloading (LVU) during VA-ECMO treatment, there are limited data on comparative outcomes. We compared outcomes of Impella and IABP for LVU during VA-ECMO. METHODS AND RESULTS: Using the Nationwide Readmissions Database between 2016 and 2020, we analyzed outcomes in 3 groups of patients with cardiogenic shock requiring VA-ECMO based on LVU strategies: extracorporeal membrane oxygenation (ECMO) only, ECMO with IABP, and ECMO with Impella. Of 15 980 patients on VA-ECMO, IABP and Impella were used in 19.4% and 16.4%, respectively. The proportion of patients receiving Impella significantly increased from 2016 to 2020 (6.5% versus 25.8%; P-trend<0.001). In-hospital mortality was higher with ECMO with Impella (54.8%) compared with ECMO only (50.4%) and ECMO with IABP (48.4%). After adjustment, ECMO with IABP versus ECMO only was associated with lower in-hospital mortality (adjusted odds ratio [aOR], 0.83; P=0.02). ECMO with Impella versus ECMO only had similar in-hospital mortality (aOR, 1.09; P=0.695) but was associated with more bleeding (aOR, 1.21; P=0.007) and more acute kidney injury requiring hemodialysis (aOR, 1.42; P<0.001). ECMO with Impella versus ECMO with IABP was associated with greater risk of acute kidney injury requiring hemodialysis (aOR, 1.49; P=0.002), higher in-hospital mortality (aOR, 1.32; P=0.001), and higher 40-day mortality (hazard ratio, 1.25; P<0.001). CONCLUSIONS: In patients with cardiogenic shock on VA-ECMO, LVU with Impella, particularly with 2.5/CP, was not associated with improved survival at 40 days but was associated with increased adverse events compared with IABP. More data are needed to assess Impella platform-specific comparative outcomes of LVU.


Subject(s)
Acute Kidney Injury , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Humans , Shock, Cardiogenic , Intra-Aortic Balloon Pumping/adverse effects , Combined Modality Therapy , Acute Kidney Injury/etiology , Treatment Outcome
8.
J Card Fail ; 30(1): 95-99, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37625582

ABSTRACT

BACKGROUND: Aortic regurgitation (AR) is a common complication following left ventricular assist device (LVAD) implantation. We evaluated the hemodynamic implications of AR in patients with HeartMate 3 (HM3) LVAD at baseline and in response to speed changes. METHODS AND RESULTS: Clinically stable outpatients supported by HM3 who underwent a routine hemodynamic ramp test were retrospectively enrolled in this analysis. Patients were stratified based on the presence of at least mild AR at baseline speed. Hemodynamic and echocardiographic parameters were compared between the AR and non-AR groups. Sixty-two patients were identified. At the baseline LVAD speed, 29 patients (47%) had AR, while 33 patients (53%) did not. Patients with AR were older and supported on HM3 for a longer duration. At baseline speed, all hemodynamic parameters were similar between the groups including central venous pressure, pulmonary capillary wedge pressure, pulmonary arterial pressures, cardiac output and index, and pulmonary artery pulsatility index (p > 0.05 for all). During the subacute assessment, AR worsened in some, but not all, patients, with increases in LVAD speed. There were no significant differences in 1-year mortality or hospitalization rates between the groups, however, at 1-year, ≥ moderate AR and right ventricular failure (RVF) were detected in higher rates among the AR group compared to the non-AR group (45% vs. 0%; p < 0.01, and 75% vs. 36.8%; p = 0.02, respectively). CONCLUSIONS: In a cohort of stable outpatients supported with HM3 who underwent a routine hemodynamic ramp test, the presence of mild or greater AR did not impact the ability of HM3 LVADs to effectively unload the left ventricle during early subacute assessment. Although the presence of AR did not affect mortality and hospitalization rates, it resulted in higher rates of late hemodynamic-related events in the form of progressive AR and RVF.


Subject(s)
Aortic Valve Insufficiency , Heart Failure , Heart-Assist Devices , Humans , Retrospective Studies , Heart Failure/diagnosis , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Hemodynamics/physiology
10.
J Heart Lung Transplant ; 43(4): 642-651, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38070663

ABSTRACT

BACKGROUND: The physiological response of the right ventricle (RV) following left ventricular assist device (LVAD) implantation is difficult to predict. We aimed to investigate RV geometric and functional changes after LVAD insertion and their effects on clinical outcomes. METHODS: We retrospectively reviewed 188 patients who underwent HeartMate 3 implantation at our center between November 2014 and September 2021. The RV end-diastolic diameter (RVEDD) and RV end-diastolic area (RVEDA) were measured on preoperative and predischarge transthoracic echocardiography. The nonadapted group included patients with increased RVEDD and RVEDA at discharge. The composite outcome was defined as death or readmission due to worsening right heart failure. RESULTS: There were 82 patients (44%) who had a nonadapted and 106 patients (56%) who had an adapted RV. Preoperatively, the nonadapted group had smaller RVEDD (46 vs 49 mm, p < 0.001) and RVEDA (27 vs 31 cm2, p < 0.001). At discharge, the nonadapted group had larger RVEDD (51 vs 43 mm, p < 0.001) and RVEDA (33 vs 27 cm2, p < 0.001). Kaplan-Meier analysis demonstrated worse 3-year survival (77% vs 91%, p = 0.006) and freedom from composite outcome (58% vs 85%, p < 0.001) in the nonadapted group. A multivariable Cox proportional hazards model showed that nonadaption (hazard ratio [HR] 3.09, 95% confidence interval [CI] 1.29-7.40, p = 0.01) and age (HR 3.73, 95% CI 1.42-9.77, p = 0.007) were independent predictors of composite outcome. CONCLUSIONS: Acute RV dimensional changes after LVAD insertion may represent intrinsic RV function and may be a useful prognostic marker.


Subject(s)
Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Right , Humans , Heart Ventricles/diagnostic imaging , Retrospective Studies , Echocardiography , Ventricular Function, Right
11.
Article in English | MEDLINE | ID: mdl-38154500

ABSTRACT

OBJECTIVE: To compare 3-year survival and readmissions of patients who received the HeartMate 3 (HM3) left ventricular assist device (LVAD) or underwent orthotopic heart transplantation (OHT) as primary treatment for advanced heart failure. METHODS: We retrospectively analyzed 381 adult patients who received an HM3 LVAD or were listed for OHT between January 2014 and March 2021 at our center. To minimize crossover bias, OHT recipients with a prior LVAD were excluded, and HM3 patients were censored at the time of transplant. Cohorts were propensity score-matched to reduce confounding variables. The primary outcome was 3-year survival, and the secondary outcome was mean cumulative all-cause unplanned readmission. RESULTS: The study population comprised 185 HM3 patients (49%) and 196 OHT patients (51%), with 104 propensity score-matched patients in each group. After propensity score matching, there was no statistical difference in 3-year survival (83.7% for HM3 vs 87.0% for OHT; P = .91; relative risk [RR], 1.00; 95% confidence interval [CI], 0.45-2.20). In the unmatched cohorts, patients age 18 to 49 years had comparable survival with HM3 and OHT (96.9% vs 95.9%; N = 91; P = 1.00; RR, 0.92; 95% CI, 0.09-9.78). Patients age 50+ years had slightly inferior survival with HM3 (75.0% vs 83.9%; N = 290; P = .60; RR, 1.51; 95% CI, 0.85-2.68). The mean number of readmissions at 3 years was higher in the HM3 group (3.89 vs 2.05; P < .001). CONCLUSIONS: This exploratory analysis suggests that for similar patients, HM3 may provide comparable 3-year survival to OHT as a primary treatment for heart failure but may result in more readmissions.

12.
ASAIO J ; 2023 Nov 07.
Article in English | MEDLINE | ID: mdl-37934714

ABSTRACT

This review discusses the challenges and outcomes associated with pregnancy during left ventricular assist device (LVAD) support. Women account for a third of the heart failure population in the United States. Left ventricular assist devices have emerged as a safe and effective treatment option for patients with advanced heart failure. Pregnancy during LVAD support can occur, and it presents significant risks to both mother and fetus, including hemodynamic stress, thrombotic events, medication-associated teratogenicity, and uterine impingement. This literature review identified 10 cases of confirmed pregnancy during LVAD support, of which eight resulted in successful births. Maternal and fetal mortality occurred in one case, and there was a spontaneous abortion in one case. The review highlights the importance of a multidisciplinary approach, promotion of shared decision-making, thoughtful anticoagulation, adjustment of LVAD speed, and medication optimization to maintain hemodynamic support during pregnancy. Hemodynamic changes during pregnancy include increased cardiac output, heart rate, and plasma volume, as well as decreased systemic vascular resistance, which can impact LVAD support. Despite reduced pulsatility in LVAD-supported patients, ovulation and reproductive capacity might be preserved, and viable pregnancies may be achieved with appropriate management. The review provides insights into the risks and considerations for a viable pregnancy during LVAD support, including the need for ongoing research to inform joined decision-making.

13.
Article in English | MEDLINE | ID: mdl-37824209

ABSTRACT

OBJECTIVES: Lateral thoracotomy (LT) approach may preserve the right ventricular (RV) function after left ventricular assist device (LVAD) implantation. This study evaluated the short- and long-term RV function using echocardiography after LVAD implantation via LT or median sternotomy (sternotomy). METHODS: The patients who underwent HeartMate 3 implantation were retrospectively reviewed. The RV function was assessed before and 1 month and 1 year after LVAD implantation. The primary and secondary outcomes were all-cause mortality and a composite of death or readmission due to RV failure, respectively. RESULTS: Of the 195 patients, 55 (28%) underwent LT and 140 (72%) underwent sternotomy. There were no significant differences in the preoperative RV geometry or function. One month after the LVAD implantation, the LT group had a smaller RV end-diastolic dimension [42 (29-48) vs 47 (42-52) mm; P = 0.003] and RV end-diastolic area [25 (21-28) vs 29 (24-36) cm2; P < 0.001] and a greater RV fractional area change [30 (25-34)% vs 28 (23-31)%; P = 0.04] and peak systolic tissue velocity [8 (7-9) vs 7 (6-8) cm/s; P = 0.01]. Twenty-four patients died and 46 met the composite end point. Kaplan-Meier curve analysis did not reveal significant differences between LT and sternotomy in the 2-year survival (93% vs 83%; log-rank test, P = 0.28) and adverse event rate (76% vs 71%; log-rank test, P = 0.65). CONCLUSIONS: LT approach yielded a better-preserved RV function at 1 month; however, there were no significant differences in the 2-year survival and adverse event rates.

14.
JTCVS Open ; 15: 262-289, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37808044

ABSTRACT

Objective: This study assessed characteristics and outcomes of younger (18-65) versus older (>65) recipients of simultaneous heart-kidney (SHK) transplantation with varying functional dependence. Methods: This study retrospectively analyzed 1398 patients from the United Network for Organ Sharing database who received SHK between 2010 and 2021. Patients who were <18 year old, underwent transplant of additional organs simultaneously, or had previous heart transplant were excluded. The primary end point was all-cause mortality, and secondary end points included adverse events and cause of death. Outcomes were also evaluated by propensity score-matched comparison. Results: The number of annual SHK transplantation in the United States has significantly increased among both age groups over the past 2 decades (P < .0001). After propensity score matching of recipients aged 18 to 65 years (n = 1162) versus age >65 years (n = 236), baseline characteristics were similar and well-balanced between the 2 cohorts. Between matched cohorts, older recipients did not have increased posttransplant mortality compared with younger recipients (90-day survival, P = .85; 7-year survival, P = .61). Multivariable Cox regression analysis found that age (hazard ratio [HR], 1.039 [0.975-1.106], P = .2415) and pretransplant functional status with interaction term for age (some assistance, HR, 0.965 [0.902-1.033], P = .3079; total assistance, HR, 0.976 [0.914-1.041], P = .4610) were not significant risk factors for 7-year post-SHK transplantation mortality. Conclusions: Older and more functionally dependent recipients in this study did not have increased post-SHK transplantation mortality. These findings have important implications for organ allocation among elderly patients, as they support the need for thorough assessment of SHK candidates in terms of comorbidities, rather than exclusion solely based on age and functional dependence.

15.
Article in English | MEDLINE | ID: mdl-37739242

ABSTRACT

BACKGROUND: Aortic root thrombosis(ART) is a complication of continuous-flow left ventricular assist device therapy. However, the incidence and related complications of ART in HeartMate 3 (HM3) patients remain unknown. METHODS: Patients who underwent HM3 implantation from November 2014 to August 2020 at a quaternary academic medical center were included. Demographics and outcomes were abstracted from the medical record. Echocardiograms and contrast-enhanced computed tomography studies were reviewed to identify patients who developed ART and/or moderate or greater aortic insufficiency (AI) on HM3 support. RESULTS: The study cohort included 197 HM3 patients with a median postimplant follow-up of 17.5 months. Nineteen patients (9.6%) developed ART during HM3 support, and 15 patients (7.6%) developed moderate or greater AI. Baseline age, gender, race, implantation strategy, and INTERMACS classification were similar between the ART and no-ART groups. ART was associated with an increased risk of death, stroke, or aortic valve (AV) intervention (subhazard ratio [SHR] 3.60 [95% confidence interval (CI) 1.71-7.56]; p = 0.001) and moderate or greater AI (SHR 11.1 [CI 3.60-34.1]; p < 0.001) but was not associated with a statistically significantly increased risk of death or stroke on HM3 support (2.12 [0.86-5.22]; p = 0.10). Of the 19 patients with ART, 6 (31.6%) developed moderate or greater AI, necessitating more frequent AV interventions (ART: 5 AV interventions [3 surgical repairs, 1 surgical replacement, 1 transcatheter replacement; 26.3%]; no-ART: 0). CONCLUSIONS: Nearly 10% of HM3 patients developed ART during device support. ART was associated with increased risk of a composite end-point of death, stroke, or AV intervention as well as moderate or greater AI.

16.
J Am Coll Cardiol ; 82(9): 771-781, 2023 08 29.
Article in English | MEDLINE | ID: mdl-37612008

ABSTRACT

BACKGROUND: In advanced heart failure patients implanted with a fully magnetically levitated HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD), it is unknown how preimplant factors and postimplant index hospitalization events influence 5-year mortality in those able to be discharged. OBJECTIVES: The goal was to identify risk predictors of mortality through 5 years among HM3 LVAD recipients conditional on discharge from index hospitalization in the MOMENTUM 3 pivotal trial. METHODS: This analysis evaluated 485 of 515 (94%) patients discharged after implantation of the HM3 LVAD. Preimplant (baseline), implant surgery, and index hospitalization characteristics were analyzed individually, and as multivariable predictors for mortality risk through 5 years. RESULTS: Cumulative 5-year mortality in the cohort (median age: 62 years, 80% male, 65% White, 61% destination therapy due to transplant ineligibility) was 38%. Two preimplant characteristics (elevated blood urea nitrogen and prior coronary artery bypass graft or valve procedure) and 3 postimplant characteristics (hemocompatibility-related adverse events, ventricular arrhythmias, and estimated glomerular filtration rate <60 mL/min/1.73 m2 at discharge) were predictors of 5-year mortality. In 171 of 485 patients (35.3%) without any risk predictors, 5-year mortality was reduced to 22.6% (95% CI: 15.4%-32.7%). Even among those with 1 or more predictors, mortality was <50% at 5 years (45.7% [95% CI: 39.0%-52.8%]). CONCLUSIONS: Long-term survival in successfully discharged HM3 LVAD recipients is largely influenced by clinical events experienced during the index surgical hospitalization in tandem with baseline factors, with mortality of <50% at 5 years. In patients without identified predictors of risk, long-term 5-year mortality is low and rivals that achieved with heart transplantation, even though most were implanted with destination therapy intent. (MOMENTUM 3 IDE Clinical Study Protocol, NCT02224755; MOMENTUM 3 Pivotal Cohort Extended Follow-up PAS, NCT03982979).


Subject(s)
Heart Failure , Heart-Assist Devices , Female , Humans , Male , Middle Aged , Coronary Artery Bypass , Heart Failure/therapy , Hospitalization , Patient Discharge
17.
Eur J Cardiothorac Surg ; 64(2)2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37589647

ABSTRACT

OBJECTIVES: We investigated the association between indexed left ventricular diastolic dimension and clinical outcomes after HeartMate 3 implantation. METHODS: We retrospectively reviewed patients implanted with the HeartMate 3 at our centre between November 2014 and September 2021. Left ventricular diastolic dimension was assessed via preoperative transthoracic echocardiography and left ventricular diastolic dimension index was calculated as left ventricular diastolic dimension/body surface area. The primary outcome was a composite of death or readmission due to right heart failure or stroke. The cut-off left ventricular diastolic dimension index value most closely associated with outcomes was determined by receiver-operating characteristic curve and restricted cubic spline analyses. RESULTS: Left ventricular diastolic dimension index measurements were available for 252 of 253 (99.6%) patients. Using a left ventricular diastolic dimension index cut-off value of 33.5 mm/m2, the cohort was divided: left ventricular diastolic dimension index ≤ (n = 131) or > (n = 121) 33.5 mm/m2. While there were no significant differences in age, INTERMACS level and preoperative haemodynamics between groups, patients with smaller left ventricular diastolic dimension index were more likely to have a larger body surface area (2.1 vs 1.9 m2, P < 0.001), ischaemic cardiomyopathy [64 (49%) vs 40 (33%), P = 0.01] and smaller left atrium volume index [40.5 (32.3-54.0) ml/m2 vs 54.0 (43.0-66.8) ml/m2, P < 0.001]. Smaller left ventricular diastolic dimension index patients had significantly worse survival (74% vs 88%, log-rank P = 0.009) and freedom from adverse events (55% vs 73%, log-rank P = 0.005) at 3-year follow-up. Smaller left ventricular diastolic dimension index was independently associated with the composite outcome (Hazard ratio 2.24, P = 0.002). CONCLUSIONS: Smaller preoperative left ventricular diastolic dimension index is associated with worse outcomes in patients undergoing HeartMate 3 implantation.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Retrospective Studies , Heart Ventricles/diagnostic imaging , Prosthesis Implantation , Echocardiography , Heart-Assist Devices/adverse effects , Treatment Outcome
19.
J Clin Med ; 12(10)2023 May 09.
Article in English | MEDLINE | ID: mdl-37240461

ABSTRACT

Primary cardiac schwannoma (PCS) is a neurogenic tumor that arises from Schwann cells. Malignant schwannoma (MSh) is an aggressive cancer comprising 2% of all sarcomas. Information on the proper management of these tumors is limited. Four databases were searched for case reports/series of PCS. The primary outcome was overall survival (OS). Secondary outcomes included therapeutic strategies and the corresponding outcomes. Among 439 potentially eligible studies, 53 met the inclusion criteria. The patients included had 43.72 ± 17.76 years and 28.3% were males. Over 50% of patients had MSh, with 9.4% also demonstrating metastases. Schwannoma commonly occurs in the atria (66.0%). Left-sided PCS were more common than right-sided ones. Surgery was performed in almost 90% of the cases; chemotherapy and radiotherapy were used in 16.9% and 15.1% of cases, respectively. Compared to benign cases, MSh occurs at a younger age and is commonly located on the left side. OS of the entire cohort at 1 and 3 years were 60.7%, and 54.0%, respectively. Females and males OS were similar up to 2 years follow-up. Surgery was associated with higher OS (p < 0.01). Surgery is the primary treatment option for both benign and malignant cases and was the only factor associated with a relative improvement in survival.

20.
J Heart Lung Transplant ; 42(9): 1223-1232, 2023 09.
Article in English | MEDLINE | ID: mdl-37098374

ABSTRACT

BACKGROUND: Reduced arterial pulsatility in continuous-flow left ventricular assist devices (CF-LVAD) patients has been implicated in clinical complications. Consequently, recent improvements in clinical outcomes have been attributed to the "artificial pulse" technology inherent to the HeartMate3 (HM3) LVAD. However, the effect of the "artificial pulse" on arterial flow, transmission of pulsatility into the microcirculation and its association with LVAD pump parameters is not known. METHODS: The local flow oscillation (pulsatility index, PI) of common carotid arteries (CCAs), middle cerebral arteries (MCAs) and central retinal arteries (CRAs-representing the microcirculation) were quantified by 2D-aligned, angle-corrected Doppler ultrasound in 148 participants: healthy controls, n = 32; heart failure (HF), n = 43; HeartMate II (HMII), n = 32; HM3, n = 41. RESULTS: In HM3 patients, 2D-Doppler PI in beats with "artificial pulse" and beats with "continuous-flow" was similar to that of HMII patients across the macro- and microcirculation. Additionally, peak systolic velocity did not differ between HM3 and HMII patients. Transmission of PI into the microcirculation was higher in both HM3 (during the beats with "artificial pulse") and in HMII patients compared with HF patients. LVAD pump speed was inversely associated with microvascular PI in HMII and HM3 (HMII, r2 = 0.51, p < 0.0001; HM3 "continuous-flow," r2 = 0.32, p = 0.0009; HM3 "artificial pulse," r2 = 0.23, p = 0.007), while LVAD pump PI was only associated with microcirculatory PI in HMII patients. CONCLUSIONS: The "artificial pulse" of the HM3 is detectable in the macro- and microcirculation but without creating a significant alteration in PI compared with HMII patients. Increased transmission of pulsatility and the association between pump speed and PI in the microcirculation indicate that the future clinical care of HM3 patients may involve individualized pump settings according to the microcirculatory PI in specific end-organs.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Microcirculation , Heart Failure/surgery , Heart Rate , Middle Cerebral Artery
SELECTION OF CITATIONS
SEARCH DETAIL
...