Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Int Heart J ; 65(2): 363-366, 2024.
Article in English | MEDLINE | ID: mdl-38556344

ABSTRACT

Congenital pulmonary lymphangiectasia (CPL) is associated with fetal pulmonary venous obstructive physiology. The precise morbidity of CPL is unknown as CPL is generally fatal in neonates. Here, we report an infant with secondary CPL in total anomalous pulmonary venous connection (TAPVC). He developed severe pulmonary hypertension (PH) after corrective surgery for TAPVC. However, cardiac catheterization showed mild left pulmonary venous obstruction (PVO), which was deemed unnecessary for re-intervention. He died at 11 months-old due to an exacerbation of PH. Autopsy revealed medial hypertrophy of the pulmonary arteries, mild left PVO, and marked dilatation and proliferation of the pulmonary lymphatics which might have been involved in the PH, although CPL was not conclusively identified based on the previous biopsy findings. We should be aware of the possibility of CPL in addition to postoperative PVO when encountering patients with fetal pulmonary venous obstructive physiology. Furthermore, a cautious approach to the interpretation of lung biopsy results is warranted.


Subject(s)
Lung Diseases/congenital , Lymphangiectasis/congenital , Pulmonary Veins , Pulmonary Veno-Occlusive Disease , Scimitar Syndrome , Infant , Infant, Newborn , Male , Humans , Pulmonary Circulation , Pulmonary Veins/surgery , Lung
2.
J Appl Oral Sci ; 29: e20200879, 2021.
Article in English | MEDLINE | ID: mdl-34320118

ABSTRACT

OBJECTIVE: Pain is a problem during bracket removal, and more comfortable treatment is needed. This study examined the association of pain with the removal force required for ceramic brackets, compared with metal and plastic brackets, to determine which removal method resulted in less pain and discomfort. METHODOLOGY: 81 subjects (mean age, 25.1 years; 25 males and 56 females) were enrolled, from whom 1,235 brackets (407 ceramic, 432 plastic, and 396 metal) were removed. Measured teeth were distinguished at six segments. Pain was measured with a visual analogue scale (VAS) during the removal of each bracket. An additional grip was placed on the grips of debonding pliers with right-angled beaks; a mini loading cell sensor pinched by the grips was used to measure removal force during debonding. VAS and force values were statistically analyzed. The Kruskal-Wallis test followed by the Mann-Whitney U test with Bonferroni correction were performed for multiple comparisons; multiple regression analysis was also performed. RESULTS: Forces in the upper and lower anterior segments were significantly smaller (p<0.05) than those in the other segments. Pain tended to be greater in the upper and lower anterior segments than in the posterior segments. In all segments, the removal force was greater for metal brackets than for plastic or ceramic brackets. Ceramic brackets caused significantly greater pain than plastic brackets for the upper and lower anterior segments. Debonding force was involved in the brackets, following adjustments for pain, upper left segment, age, and sex. CONCLUSIONS: Pain and discomfort are likely to occur during bracket debonding.


Subject(s)
Dental Debonding , Orthodontic Brackets , Adult , Animals , Ceramics , Dental Debonding/adverse effects , Humans , Orthodontic Brackets/adverse effects , Pain
3.
J. appl. oral sci ; 29: e20200879, 2021. tab, graf
Article in English | LILACS | ID: biblio-1286922

ABSTRACT

Abstract Objective: Pain is a problem during bracket removal, and more comfortable treatment is needed. This study examined the association of pain with the removal force required for ceramic brackets, compared with metal and plastic brackets, to determine which removal method resulted in less pain and discomfort. Methodology: 81 subjects (mean age, 25.1 years; 25 males and 56 females) were enrolled, from whom 1,235 brackets (407 ceramic, 432 plastic, and 396 metal) were removed. Measured teeth were distinguished at six segments. Pain was measured with a visual analogue scale (VAS) during the removal of each bracket. An additional grip was placed on the grips of debonding pliers with right-angled beaks; a mini loading cell sensor pinched by the grips was used to measure removal force during debonding. VAS and force values were statistically analyzed. The Kruskal-Wallis test followed by the Mann-Whitney U test with Bonferroni correction were performed for multiple comparisons; multiple regression analysis was also performed. Results: Forces in the upper and lower anterior segments were significantly smaller (p<0.05) than those in the other segments. Pain tended to be greater in the upper and lower anterior segments than in the posterior segments. In all segments, the removal force was greater for metal brackets than for plastic or ceramic brackets. Ceramic brackets caused significantly greater pain than plastic brackets for the upper and lower anterior segments. Debonding force was involved in the brackets, following adjustments for pain, upper left segment, age, and sex. Conclusions Pain and discomfort are likely to occur during bracket debonding.


Subject(s)
Humans , Animals , Adult , Orthodontic Brackets/adverse effects , Dental Debonding/adverse effects , Pain , Ceramics
SELECTION OF CITATIONS
SEARCH DETAIL
...