Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Gan To Kagaku Ryoho ; 51(6): 637-641, 2024 Jun.
Article in Japanese | MEDLINE | ID: mdl-39009522

ABSTRACT

At Oita University Hospital, we switched our usage of pemetrexed(PEM)from brand-name to generic drugs. We conducted a comparative study of the preparation efficiency and therapeutic safety with the brand-name product and examined the economic effect thereof. The incidence of adverse drug reactions was investigated retrospectively using electronic medical records for patients who received PEM brand-name and generic drugs at our hospital between April 2021 and December 2022. The preparation time per mg was significantly shorter in the generic group at 0.17(0.08-0.38)seconds compared to 0.34(0.15-0.94)seconds for the brand-name group(p<0.01). Regarding the safety comparison, none of the 13 eligible patients developed new hematologic or non-hematologic toxicities of Grade 2 or higher after switching to the generic product. The switch to generics had an economic impact of 7,369,278 yen during the study period. The results suggest that switching from brand-name to generic products is reasonable from the perspectives of therapeutic safety and economic benefits, as well as the expected improvement in preparation efficiency.


Subject(s)
Drugs, Generic , Pemetrexed , Drugs, Generic/economics , Drugs, Generic/adverse effects , Humans , Pemetrexed/adverse effects , Pemetrexed/administration & dosage , Male , Female , Aged , Middle Aged , Retrospective Studies
2.
Ther Drug Monit ; 44(3): 419-429, 2022 06 01.
Article in English | MEDLINE | ID: mdl-34469417

ABSTRACT

BACKGROUND: Breakpoint cluster region-Abelson (BCR-ABL) tyrosine kinase inhibitors (TKIs) demonstrate improved therapeutic efficacy in chronic myeloid leukemia (CML). However, drug-drug interactions, nonadherence, and host-related factors may influence plasma concentrations. Therefore, therapeutic drug monitoring may be necessary for patients presenting inadequate treatment responses or adverse events. Herein, the authors aimed to develop a more sensitive and high-throughput method than those previously reported to simultaneously quantify 5 TKIs (imatinib, nilotinib, dasatinib, bosutinib, and ponatinib) and 2 active metabolites (N-desmethyl imatinib and N-desmethyl ponatinib) using ultra-performance liquid chromatography coupled with tandem mass spectrometry. METHODS: Plasma samples were prepared according to a solid-phase extraction protocol using an Oasis MCX µElution plate. The assay fulfilled the requirements of the US Food and Drug Administration for assay validation, with a lower limit of quantification of 0.2 ng/mL for dasatinib, 0.3 ng/mL for N-desmethyl ponatinib, 0.5 ng/mL for N-desmethyl imatinib, bosutinib, and ponatinib, and 2.5 ng/mL for imatinib and nilotinib. RESULTS: Within-batch and batch-to-batch precision at the lower limit of quantification and quality control levels were within 14.3% and 10.9%, respectively. Within-batch and batch-to-batch accuracies ranged from 15.5% to 13.0% and 5.70% to 7.03%, respectively. A positive electrospray ionization mode was used with a run time of 6.0 minutes. The assay applicability was verified by the successful measurement of 78 clinical samples from patients undergoing CML therapy. CONCLUSIONS: The method allows assessment of trough concentrations of TKIs and active metabolites in patients with CML, and hence can be used to assess blood samples in routine clinical settings.


Subject(s)
Antineoplastic Agents , Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Antineoplastic Agents/therapeutic use , Chromatography, High Pressure Liquid/methods , Dasatinib/therapeutic use , Humans , Imatinib Mesylate/therapeutic use , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/drug therapy , Protein Kinase Inhibitors , Tandem Mass Spectrometry/methods
3.
Clin Case Rep ; 9(8): e04357, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34429976

ABSTRACT

Fixed dose regimen is currently the standard administration method for TKI. However, this case report indicated that TDM may by a useful approach to individualized dosing of TKI for the treatment of CML when initiating dialysis.

4.
Gan To Kagaku Ryoho ; 48(7): 945-949, 2021 Jul.
Article in Japanese | MEDLINE | ID: mdl-34267033

ABSTRACT

At the Oita University Hospital, we switched from using the original biological product of trastuzumab(original product) to a biosimilar product, and verified the appropriateness of the switch by investigating the occurrence of adverse events. We compared the safety of the original and biosimilar products from January 2019 to September 2020. Of 14 cases studied, there were 6 in the original product group, 6 in the switched group, and 2 in the biosimilar group. In 3 patients in the switched group, infusion reaction was observed during administration of the original product, and was appropriately managed at that time. After switching to the biosimilar product, it was possible to administer the drug safely even when the infusion time was shortened. The results of this study showed that no adverse events were observed after switching from the original to the biosimilar product. This finding suggests that switching products is appropriate, not only from an economic point of view but also from the perspective of treatment safety.


Subject(s)
Biosimilar Pharmaceuticals , Biosimilar Pharmaceuticals/adverse effects , Humans , Remission Induction , Trastuzumab/adverse effects
5.
Clin Case Rep ; 7(7): 1419-1421, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31360502

ABSTRACT

Fixed dosage regimen is currently the standard therapy with tyrosine kinase inhibitors (TKI). This case report demonstrates successful determination of nilotinib dosage by therapeutic drug monitoring (TDM) in a patient with chronic myeloid leukemia (CML). TDM may provide useful marker for individualized dosing of TKI for the treatment of CML.

6.
J Clin Lab Anal ; 32(1)2018 Jan.
Article in English | MEDLINE | ID: mdl-28374910

ABSTRACT

BACKGROUND: We propose a simple, sensitive, and fast high-performance liquid chromatography ultraviolet detection (HPLC-UV) method for the quantitative determination of bosutinib in human plasma. METHODS: Plasma samples were processed using an Oasis hydrophilic-lipophilic balance extraction cartridge (1 mL, 30 mg). Bosutinib and the internal standard imatinib were separated using a mobile phase of 0.5% Na2 PO4 H2 O (pH 3.5)-acetonitrile-methanol (55:25:20, v/v/v) on a CAPCELL PAK C18 MG II reversed-phase column 250 nm×4.6 nm i.d., at a flow rate of 1.0 mL/min, with ultraviolet detection at 250 nm. RESULTS: The calibration curve exhibited linearity over the bosutinib concentration range of 25-1500 ng/mL at 250 nm, with coefficient of variation for intraday precision of 2.42%, 6.04%, and 1.11% for 100, 250, and 1500 ng/mL, respectively, of bosutinib. The lower limit of detection was 20 ng/mL. The extraction recovery rates for bosutinib ranged from 84.36% to 85.82%. The intra- and interday precision was below 8.7%, and the accuracy ranged from -5.95% to 5.85% over the linear range. No notable matrix effects or astaticism were observed. CONCLUSION: The proposed HPLC-UV method was successfully applied as an assay to detect bosutinib in human plasma.


Subject(s)
Aniline Compounds/blood , Nitriles/blood , Quinolines/blood , Chromatography, High Pressure Liquid/methods , Humans , Linear Models , Reproducibility of Results , Sensitivity and Specificity , Spectrophotometry, Ultraviolet/methods
7.
Gan To Kagaku Ryoho ; 44(4): 319-323, 2017 Apr.
Article in Japanese | MEDLINE | ID: mdl-28428513

ABSTRACT

Because generic medicines reduce the financialburden on patients and medicalinsurance providers, they have become increasingly popular. However, there are only a few reports that have analyzed the efficacy and safety of generic medicines, especially in terms of their characteristics and side effects. Gemcitabine is an antineoplastic drug that is frequently used with good results in the treatment of lung cancer, pancreatic cancer, breast cancer, ovarian cancer, and malignant lymphoma. However, its fat solubility is high, and several adverse events, such as myelosuppression, are known to develop during its use. We investigated the efficacy, characteristics, and the incidence of adverse events for the generic versions of gemcitabine. We found differences between the generic versions in terms of the characteristics and preparation time; however, the incidence of adverse events was not significantly different, suggesting that the generic versions could be a reasonable substitute.


Subject(s)
Antimetabolites, Antineoplastic/therapeutic use , Deoxycytidine/analogs & derivatives , Drugs, Generic/therapeutic use , Pancreatic Neoplasms/drug therapy , Aged , Aged, 80 and over , Antimetabolites, Antineoplastic/adverse effects , Deoxycytidine/adverse effects , Deoxycytidine/therapeutic use , Drugs, Generic/administration & dosage , Female , Humans , Male , Middle Aged , Neoplasm Metastasis , Pancreatic Neoplasms/pathology , Gemcitabine
8.
J Clin Lab Anal ; 30(6): 1028-1030, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27194024

ABSTRACT

BACKGROUND: A method for determining nilotinib concentration in human plasma is proposed using high-performance liquid chromatography and ultraviolet detection. MATERIALS & METHODS: Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% Na2 PO4 H2 O (pH 2.5)-acetonitrile-methanol (55:25:20, v/v/v) on a Capcell Pak C18 MG II column (250 × 4.6 mm) at a flow rate of 1.0 ml/min, and ultraviolet measurement at 250 nm. RESULTS: The calibration curve exhibited linearity over the nilotinib concentration range of 50-2,500 ng/ml at 250 nm, with relative standard deviations (n = 5) of 7.1%, 2.5%, and 2.9% for 250, 1,500, and 2,500 ng/ml, respectively. The detection limit for nilotinib was 5 ng/ml due to three blank determinations (ρ = 3). CONCLUSION: This method was successfully applied to assaying nilotinib in human plasma samples from patients with chronic myelogenous leukemia. In addition, we compared the results with those measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at BML, Inc. (a commercial laboratory). A strong correlation was observed between the nilotinib concentrations measured by our high-performance liquid chromatographic method and those obtained by LC/MS-MS (r2 = 0.988, P < 0.01).


Subject(s)
Chromatography, High Pressure Liquid/methods , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/blood , Pyrimidines/blood , Spectrophotometry, Ultraviolet/methods , Tandem Mass Spectrometry/methods , Humans , Limit of Detection , Pyrimidines/analysis
9.
J Biosci Bioeng ; 118(1): 98-100, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24485745

ABSTRACT

Rhodamine B hydrazide can be used to detect hydroxyl radicals in plant cells. RBH was easily inserted into plant cells without any pretreatment, and specifically reacted with intracellular hydroxyl radicals produced by antimycin A. RBH will be a powerful tool for detecting hydroxyl radicals in plant cells.


Subject(s)
Fluorescent Dyes/chemistry , Hydrazines/chemistry , Hydroxyl Radical/analysis , Plant Cells/chemistry , Rhodamines/chemistry , Microscopy, Confocal , Molecular Probes/chemistry
10.
Yakugaku Zasshi ; 129(4): 459-63, 2009 Apr.
Article in Japanese | MEDLINE | ID: mdl-19337000

ABSTRACT

A simple and sensitive fluorophotometric method for the determination of aldehyde was established by utilizing condensation reaction with resorcinol. In the determination of vanillin that is one of aldehydes, the calibration curve exhibited linearity over the vanillin concentration range of 3.0-7600 ng ml(-1) at an emission wavelength of 507 nm with an excitation of 410 nm and with the relative standard deviations (n=5) of 2.5%, 2.0% for 7.6 ng ml(-1), 760 ng ml(-1) of vanillin, respectively. This method was successfully applied in the assay of vanillin in cold medicine.


Subject(s)
Aldehydes/analysis , Fluorophotometry/methods , Resorcinols , Aldehydes/chemistry , Benzaldehydes/analysis , Benzaldehydes/chemistry , Organic Chemistry Phenomena
11.
J Fluoresc ; 19(5): 769-75, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19255831

ABSTRACT

A fluorophotometric method for the determination of hydrogen peroxide (H2O2) using fluorescin was developed. This method was based on the oxidative reaction of fluorescin, a colorless, non-fluorescent lactoid fluorescein, by H2O2 to give highly fluorescein fluorescence emission. In the determination of H2O2, the calibration curve exhibited linearity over the H2O2 concentration range of 1.5-310 ng mL(-1) at an emission wavelength of 525 nm with an excitation of 500 nm and with relative standard deviations (n = 6) of 2.51%, 2.48%, and 1.31% for 3.1 ng mL(-1), 30.8 ng mL(-1), and for 308 ng mL(-1) of H2O2, respectively. The detection limit for H2O2 was 1.9 ng mL(-1) six blank determinations was performed (rho = 6). This proposed method was applied to detection of other reactive oxygen species and nitrogen species (ROS/RNS) such as singlet oxygen (1O2), hydroxyl radical (*OH), peroxynitrite (ONOO-) etc., and it was possible to detect them with a high sensitivity. In addition, this proposed method was applied to the recovery tests of H2O2 in calf serum, human saliva, rain water, and wheat noodles; the results were satisfactory.


Subject(s)
Cobalt/chemistry , Fluoresceins/chemistry , Hydrogen Peroxide/analysis , Reactive Oxygen Species/analysis , Animals , Cattle , Flour/analysis , Fluoresceins/analysis , Fluorophotometry , Humans , Hydrogen Peroxide/chemistry , Reactive Nitrogen Species/analysis , Saliva/chemistry , Water/chemistry
12.
Anal Sci ; 25(1): 125-8, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19139586

ABSTRACT

A simple and sensitive spectrophotometric method for the determination of quinolone antibiotics was established based on an association complex formation with aluminum(III) and erythrosin. In the determination of ofloxacin as a quinolone antibiotic, Beer's law is obeyed in the range of 0.1 - 3.2 microg ml(-1), with an effective molar absorptivity at 555 nm and the relative standard deviation being 1.2 x 10(5) L mol(-1) cm(-1) and 0.9% (n = 6). This method was successfully applied to the assay of quinolone antibiotics in pharmaceutical preparations.


Subject(s)
Anti-Bacterial Agents/analysis , Quinolines/analysis , Aluminum/chemistry , Erythrosine/chemistry , Ofloxacin/analysis , Spectrum Analysis
13.
Chem Pharm Bull (Tokyo) ; 56(7): 977-81, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18591813

ABSTRACT

Methods for the fluorophotometric determination of hydrogen peroxide (H(2)O(2)) and other reactive oxygen species (ROS) were proposed by using the fluorescence reaction between H(2)O(2) or other ROS and fluorescein hydrazide (FH). In the determination of H(2)O(2), the calibration curve exhibited linearity over the H(2)O(2) concentration range of 2.1-460 ng ml(-1) at an emission wavelength of 527 nm with an excitation of 460 nm and with the relative standard deviations (n=6) of 4.06%, 1.78%, and 2.21% for 3.1 ng ml(-1), 30.8 ng ml(-1), and for 308 ng ml(-1) of H(2)O(2), respectively. The detection limit for H(2)O(2) was 0.7 ng ml(-1) due to three blank determinations (rho=3). The calibration curves for ROS-related compounds were also constructed under the optimum conditions. This method was successfully applied in the assay of H(2)O(2) in human urine. In addition, we performed the characterization of FH, and interesting information was obtained with regard to the relationship between the chemical structure and fluorescence.


Subject(s)
Fluoresceins/chemistry , Fluorophotometry/methods , Hydrogen Peroxide/analysis , Reactive Oxygen Species/analysis , Calibration , Hydrogen Peroxide/chemistry , Reactive Oxygen Species/chemistry , Reproducibility of Results
14.
Anal Sci ; 23(5): 601-4, 2007 May.
Article in English | MEDLINE | ID: mdl-17495409

ABSTRACT

A simple and rapid spectrophotometric method for the determination of oxalate ion was established by the fading of a colored complex between N,N'-diethyl-N,N'-[[4,4'-dihydroxy-1,1'-binaphthalene]-3,3'-diyl]bisbenzamide and copper(II). Beer's law was obeyed in the concentration range of 0.1 - 2.0 microg cm(-3) for oxalate ion, with an effective molar absorptivity at 533 nm and the relative standard deviation being 8.0 x 10(3) dm(3) mol(-1) cm(-1) and 1.0% (n = 5), respectively. This proposed method has excellent reproducibility, and was applied to recovery tests of oxalate ion in tap water and human urine; the results were satisfactory. This is suggested that the method is based on the reaction of copper(II) to copper(I) with oxalate ion.


Subject(s)
Benzamides , Copper/chemistry , Naphthalenes , Oxalates/chemistry , Spectrophotometry/methods , Humans , Oxalates/urine , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...