Leg Med (Tokyo) ; 47: 101776, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32795931

ABSTRACT

The RapidHIT™ ID system produces GlobalFiler™ analysis results after a short operating time. This device is effective because it automatically extracts DNA from oral mucosal cells or from blood stains and saliva collected at a crime scene, with subsequent polymerase chain reaction performed to produce a DNA profile. Two types of dedicated cartridges are available for RapidHIT™ ID: the RapidHIT™ ID ACE GlobalFiler Express sample cartridge for oral cells and other samples and the RapidINTEL™ sample cartridge for minute samples, such as blood stains. Previously validated specimens include oral mucosa cells and blood stains left at crime scenes. There have been no reports of blood and nail clipping samples collected from the postmortem bodies at the time of death. This report summarizes the results of using the RapidHIT™ ID system by collecting a variety of actual forensic samples from postmortem bodies at different stages of decomposition, which were subsequently analyzed using these cartridges.


Subject(s)
Autopsy/methods , DNA Fingerprinting/instrumentation , DNA/genetics , DNA/isolation & purification , Forensic Genetics , Blood Stains , Crime , DNA Fingerprinting/methods , Humans , Mouth Mucosa , Polymerase Chain Reaction , Saliva
2.
Leg Med (Tokyo) ; 36: 85-88, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30448603

ABSTRACT

We report a case of sudden death in a patient who developed extensive gastric necrosis secondary to acute gastric dilatation. A 36-year-old man with mental retardation (but without difficulties in activities of daily living), developed an illness after a meal out with friends, necessitating 3 hospital visits. He returned home after receiving drug therapy; however, his condition deteriorated, and he was transferred to our hospital via ambulance. Whole-body computed tomography performed upon admission revealed gastric dilatation. A stomach tube was inserted, and 2000 mL of gastric aspirate was obtained. The patient died approximately 5 h later despite receiving treatment. Autopsy revealed 1000 mL of gastric contents and extensive gastric necrosis. He was diagnosed with extensive gastric necrosis secondary to acute gastric dilatation.


Subject(s)
Gastric Dilatation/complications , Stomach/pathology , Acute Disease , Adult , Autopsy , Fatal Outcome , Gastric Dilatation/diagnostic imaging , Gastric Dilatation/pathology , Humans , Male , Necrosis/diagnosis , Necrosis/etiology , Tomography, X-Ray Computed
3.
Forensic Sci Int ; 227(1-3): 90-4, 2013 Apr 10.
Article in English | MEDLINE | ID: mdl-23266306

ABSTRACT

We attempted the simultaneous determination of 5 drugs, mirtazapine, sertraline, chlorpromazine, amoxapine and zolpidem, detected in a gas chromatography-mass spectrometry screening test in an autopsy case. The solid-phase extraction of the analytes from biological samples was achieved using Oasis(®)HLB cartridges (Waters, Milford, MA, USA). Gas chromatography was performed on a HP-5MS fused silica capillary column (30 m × 0.25 mm i.d., 0.25 µm film thickness, Agilent Technologies). The mass spectrometer was operated with an electron energy of 70 eV in electron impact mode. The qualitative and quantitative analyses were performed in full-scan mode and the selected ion monitoring mode, respectively. The total ion chromatogram showed good separation of these drugs. Linear graphs were obtained with good correlation coefficients for these drugs from 0.001 to 2.0 µg/mL (r(2)=0.9909-0.9986) using imipramine-d6 as an internal standard. The recoveries of these drugs were found to be 62.8-88.0% in spiked whole blood. Mirtazapine, sertraline, chlorpromazine, amoxapine and zolpidem were found in post-mortem samples of the deceased at concentrations of 2.67, 0.07, 0.25, 0.32 and 0.68 µg/mL, respectively. The concentration of mirtazapine was within the lethal level and those of amoxapine and zolpidem were within the toxic level. We diagnosed that the cause of death was acute multiple drug poisoning. The simple and practical procedure used in this study is useful for the simultaneous determination of psychotropic drugs of various types in post-mortem biological samples.


Subject(s)
Psychotropic Drugs/analysis , Psychotropic Drugs/poisoning , Adult , Amoxapine/analysis , Amoxapine/poisoning , Chlorpromazine/analysis , Chlorpromazine/poisoning , Female , Forensic Toxicology , Gas Chromatography-Mass Spectrometry/methods , Gastrointestinal Contents/chemistry , Humans , Mianserin/analogs & derivatives , Mianserin/analysis , Mianserin/poisoning , Mirtazapine , Pyridines/analysis , Pyridines/poisoning , Sertraline/analysis , Sertraline/poisoning , Solid Phase Extraction , Zolpidem
4.
Leg Med (Tokyo) ; 15(2): 57-60, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23067801

ABSTRACT

ABO genotyping have become common tools for forensic casework. We developed a new rapid ABO genotyping method using a fast real-time PCR system with the TaqMan® Sample-to-SNP™ Kit. Eight single nucleotide polymorphism (SNP) sites in the ABO gene (nt 261, 297, 467, 657, 703, 829, 930 and 1061) were selected to determine the ABO genotypes. ABO genotypes were easily determined by examining allelic discrimination patterns. This method enabled analyses to be completed in about 1h per plate with no postmortem change influences. The detection limit in each SNP site was examined as 100pg per reaction. ABO genotyping from 1000 Japanese individuals was also examined to determine the distribution of ABO genotypes and allele frequencies. Thus, 31 genotypes were clearly identified, and these were controlled by four common and seven rare alleles. The power of discrimination, heterozygosity and polymorphism information contents were 0.913, 0.775 and 0.812, respectively. Therefore, selecting these eight SNP sites could be useful for high specific ABO genotyping. This rapid, sensitive and accurate genotyping method is useful for forensic casework.


Subject(s)
ABO Blood-Group System/genetics , Gene Frequency , Real-Time Polymerase Chain Reaction/instrumentation , Asian People/genetics , DNA Primers , DNA Probes , Genotype , Humans , Japan , Polymorphism, Single Nucleotide
5.
Leg Med (Tokyo) ; 12(6): 280-3, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20817590

ABSTRACT

Developments in the molecular genetic studies of cardiomyopathy (CM) have led to discovery of a large number of mutations in the genes encoding the sarcomeric proteins. In this study, comprehensive screening of TNNI3 was performed in 36 consented autopsy cases diagnosed as CM, in order to evaluate the prevalence of gene mutations in sudden death caused by CM. In DCM cases, a new missense mutation Pro16Thr was detected. A single nucleotide polymorphism at -8 position of intron 3 (IVS 3 -8 T>A) was identified, which had a significant difference in allele frequency between DCM and control cases. From these results, it was indicated that this study contribute to genetic based diagnosis, risk stratification and prevention of sudden death caused by CM.


Subject(s)
Cardiomyopathy, Dilated/genetics , Polymorphism, Genetic , Sarcomeres/genetics , Troponin I/genetics , Adult , Aged , Autopsy , Death, Sudden, Cardiac/etiology , Female , Forensic Pathology , Humans , Male , Middle Aged , Sarcomeres/metabolism , Sequence Analysis, DNA , Troponin I/metabolism
6.
Leg Med (Tokyo) ; 11(1): 25-9, 2009 Jan.
Article in English | MEDLINE | ID: mdl-18789874

ABSTRACT

A man in his sixties, who developed CPA at home, was transferred to the emergency center. Since CT images revealed a tube-shaped foreign body in the pulmonary artery, pulmonary embolism was initially suspected; however, this did not lead to a definite diagnosis. Autopsy revealed that the foreign body in the cadaver was a fragment of a V-A shunt catheter implanted about 30 years previously for the treatment of hydrocephalus. Although fibrous adhesion of a part of the catheter to the pulmonary artery wall was seen, suggesting that a fracture of the catheter had occurred a long time before, it was not known when the fracture had occurred. Since no pulmonary arterial obstruction secondary to the catheter or new thrombi, which had been initially suspected, were observed, the cause of death was determined to be ischemic cardiac failure. A fracture of a shunt catheter may be typically associated with some clinical manifestations, which are often found and treated. In this case, however, no symptoms appeared and the fracture of the shunt catheter remained untreated for a long time. This case was therefore considered to be extremely rare, and is an example of how a serious iatrogenic disease could occur.


Subject(s)
Cerebrospinal Fluid Shunts/adverse effects , Equipment Failure , Foreign-Body Migration/pathology , Pulmonary Artery , Humans , Hydrocephalus/surgery , Male , Middle Aged , Pulmonary Artery/pathology