Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Int Heart J ; 63(5): 939-947, 2022 Sep 30.
Article in English | MEDLINE | ID: mdl-36104234

ABSTRACT

Left ventricular dilatation (LVD) and left ventricular hypertrophy (LVH) are risk factors for heart failure, and their detection improves heart failure screening. This study aimed to investigate the ability of deep learning to detect LVD and LVH from a 12-lead electrocardiogram (ECG). Using ECG and echocardiographic data, we developed deep learning and machine learning models to detect LVD and LVH. We also examined conventional ECG criteria for the diagnosis of LVH. We calculated the area under the receiver operating characteristic (AUROC) curve, sensitivity, specificity, and accuracy of each model and compared the performance of the models. We analyzed data for 18,954 patients (mean age (standard deviation): 64.2 (16.5) years, men: 56.7%). For the detection of LVD, the value (95% confidence interval) of the AUROC was 0.810 (0.801-0.819) for the deep learning model, and this was significantly higher than that of the logistic regression and random forest methods (P < 0.001). The AUROCs for the logistic regression and random forest methods (machine learning models) were 0.770 (0.761-0.779) and 0.757 (0.747-0.767), respectively. For the detection of LVH, the AUROC was 0.784 (0.777-0.791) for the deep learning model, and this was significantly higher than that of the logistic regression and random forest methods and conventional ECG criteria (P < 0.001). The AUROCs for the logistic regression and random forest methods were 0.758 (0.751-0.765) and 0.716 (0.708-0.724), respectively. This study suggests that deep learning is a useful method to detect LVD and LVH from 12-lead ECGs.


Subject(s)
Deep Learning , Heart Failure , Dilatation , Electrocardiography/methods , Humans , Hypertrophy, Left Ventricular/diagnostic imaging , Male
2.
J Cardiol ; 79(3): 334-341, 2022 03.
Article in English | MEDLINE | ID: mdl-34544652

ABSTRACT

BACKGROUND: Aortic regurgitation (AR) is a common heart disease, with a relatively high prevalence of 4.9% in the Framingham Heart Study. Because the prevalence increases with advancing age, an upward shift in the age distribution may increase the burden of AR. To provide an effective screening method for AR, we developed a deep learning-based artificial intelligence algorithm for the diagnosis of significant AR using electrocardiography (ECG). METHODS: Our dataset comprised 29,859 paired data of ECG and echocardiography, including 412 AR cases, from January 2015 to December 2019. This dataset was divided into training, validation, and test datasets. We developed a multi-input neural network model, which comprised a two-dimensional convolutional neural network (2D-CNN) using raw ECG data and a fully connected deep neural network (FC-DNN) using ECG features, and compared its performance with the performances of a 2D-CNN model and other machine learning models. In addition, we used gradient-weighted class activation mapping (Grad-CAM) to identify which parts of ECG waveforms had the most effect on algorithm decision making. RESULTS: The area under the receiver operating characteristic curve of the multi-input model (0.802; 95% CI, 0.762-0.837) was significantly greater than that of the 2D-CNN model alone (0.734; 95% CI, 0.679-0.783; p<0.001) and those of other machine learning models. Grad-CAM demonstrated that the multi-input model tended to focus on the QRS complex in leads I and aVL when detecting AR. CONCLUSIONS: The multi-input deep learning model using 12-lead ECG data could detect significant AR with modest predictive value.


Subject(s)
Aortic Valve Insufficiency , Deep Learning , Algorithms , Aortic Valve Insufficiency/diagnosis , Artificial Intelligence , Electrocardiography/methods , Humans , Retrospective Studies
3.
Int Heart J ; 62(6): 1332-1341, 2021.
Article in English | MEDLINE | ID: mdl-34853226

ABSTRACT

Deep learning models can be applied to electrocardiograms (ECGs) to detect left ventricular (LV) dysfunction. We hypothesized that applying a deep learning model may improve the diagnostic accuracy of cardiologists in predicting LV dysfunction from ECGs. We acquired 37,103 paired ECG and echocardiography data records of patients who underwent echocardiography between January 2015 and December 2019. We trained a convolutional neural network to identify the data records of patients with LV dysfunction (ejection fraction < 40%) using a dataset of 23,801 ECGs. When tested on an independent set of 7,196 ECGs, we found the area under the receiver operating characteristic curve was 0.945 (95% confidence interval: 0.936-0.954). When 7 cardiologists interpreted 50 randomly selected ECGs from the test dataset of 7,196 ECGs, their accuracy for predicting LV dysfunction was 78.0% ± 6.0%. By referring to the model's output, the cardiologist accuracy improved to 88.0% ± 3.7%, which indicates that model support significantly improved the cardiologist diagnostic accuracy (P = 0.02). A sensitivity map demonstrated that the model focused on the QRS complex when detecting LV dysfunction on ECGs. We developed a deep learning model that can detect LV dysfunction on ECGs with high accuracy. Furthermore, we demonstrated that support from a deep learning model can help cardiologists to identify LV dysfunction on ECGs.


Subject(s)
Deep Learning , Electrocardiography , Ventricular Dysfunction, Left/diagnosis , Adult , Aged , Aged, 80 and over , Cardiologists , Decision Support Systems, Clinical , Female , Humans , Male , Middle Aged , Sensitivity and Specificity , Systole
4.
PLoS One ; 16(8): e0255577, 2021.
Article in English | MEDLINE | ID: mdl-34351974

ABSTRACT

Intravascular ultrasound (IVUS) is a diagnostic modality used during percutaneous coronary intervention. However, specialist skills are required to interpret IVUS images. To address this issue, we developed a new artificial intelligence (AI) program that categorizes vessel components, including calcification and stents, seen in IVUS images of complex lesions. When developing our AI using U-Net, IVUS images were taken from patients with angina pectoris and were manually segmented into the following categories: lumen area, medial plus plaque area, calcification, and stent. To evaluate our AI's performance, we calculated the classification accuracy of vessel components in IVUS images of vessels with clinically significantly narrowed lumina (< 4 mm2) and those with severe calcification. Additionally, we assessed the correlation between lumen areas in manually-labeled ground truth images and those in AI-predicted images, the mean intersection over union (IoU) of a test set, and the recall score for detecting stent struts in each IVUS image in which a stent was present in the test set. Among 3738 labeled images, 323 were randomly selected for use as a test set. The remaining 3415 images were used for training. The classification accuracies for vessels with significantly narrowed lumina and those with severe calcification were 0.97 and 0.98, respectively. Additionally, there was a significant correlation in the lumen area between the ground truth images and the predicted images (ρ = 0.97, R2 = 0.97, p < 0.001). However, the mean IoU of the test set was 0.66 and the recall score for detecting stent struts was 0.64. Our AI program accurately classified vessels requiring treatment and vessel components, except for stents in IVUS images of complex lesions. AI may be a powerful tool for assisting in the interpretation of IVUS imaging and could promote the popularization of IVUS-guided percutaneous coronary intervention in a clinical setting.


Subject(s)
Algorithms , Artificial Intelligence , Coronary Angiography/methods , Coronary Artery Disease/pathology , Coronary Vessels/pathology , Deep Learning , Ultrasonography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Humans , Image Processing, Computer-Assisted
5.
Circ J ; 86(1): 87-95, 2021 12 24.
Article in English | MEDLINE | ID: mdl-34176867

ABSTRACT

BACKGROUND: Because the early diagnosis of subclinical cardiac sarcoidosis (CS) remains difficult, we developed a deep learning algorithm to distinguish CS patients from healthy subjects using echocardiographic movies.Methods and Results:Among the patients who underwent echocardiography from January 2015 to December 2019, we chose 151 echocardiographic movies from 50 CS patients and 151 from 149 healthy subjects. We trained two 3D convolutional neural networks (3D-CNN) to identify CS patients using a dataset of 212 echocardiographic movies with and without a transfer learning method (Pretrained algorithm and Non-pretrained algorithm). On an independent set of 41 echocardiographic movies, the area under the receiver-operating characteristic curve (AUC) of the Pretrained algorithm was greater than that of Non-pretrained algorithm (0.842, 95% confidence interval (CI): 0.722-0.962 vs. 0.724, 95% CI: 0.566-0.882, P=0.253). The AUC from the interpretation of the same set of 41 echocardiographic movies by 5 cardiologists was not significantly different from that of the Pretrained algorithm (0.855, 95% CI: 0.735-0.975 vs. 0.842, 95% CI: 0.722-0.962, P=0.885). A sensitivity map demonstrated that the Pretrained algorithm focused on the area of the mitral valve. CONCLUSIONS: A 3D-CNN with a transfer learning method may be a promising tool for detecting CS using an echocardiographic movie.


Subject(s)
Deep Learning , Myocarditis , Sarcoidosis , Algorithms , Echocardiography , Humans , Motion Pictures , Sarcoidosis/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...