Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 119
Filter
1.
Article in English | MEDLINE | ID: mdl-38771361

ABSTRACT

INTRODUCTION: Bone maintenance after total hip arthroplasty (THA) is important for implant success. This study aimed to investigate the relationship between patient characteristics and periprosthetic bone maintenance after THA for better implant selection. MATERIALS AND METHODS: This retrospective cohort study enrolled 112 consecutive patients who underwent THA using full hydroxyapatite (HA) compaction with short (n = 55) or short-tapered wedge (n = 61) stems. Periprosthetic bone mineral density (BMD) was compared between the two groups after propensity score matching, and the relationship between periprosthetic BMD changes and patient background was analyzed. RESULTS: Both groups showed similar periprosthetic BMD changes after adjusting for patient background using propensity score matching. Canal flare index > 3.7 in patients that underwent THA using tapered-wedge stem (odds ratio (OR), 3.2; 95% confidence interval (CI), 1.3-7.9, p = 0.013) and baseline zone 1 BMD > 0.65 in patients that received with short HA compaction stems (OR, 430.0; 95% CI 1.3-1420, p = 0.040) were associated with proximal periprosthetic bone maintenance after THA. CONCLUSION: Considering their predictive value, canal flare index and zone 1 BMD assessment might be useful strategies for implant selection during THA.

2.
Eur J Orthop Surg Traumatol ; 34(4): 2185-2191, 2024 May.
Article in English | MEDLINE | ID: mdl-38573382

ABSTRACT

PURPOSE: The indication for unicompartmental knee arthroplasty (UKA) has been extended to cases with some degree of preoperative knee flexion contracture recently. The purpose of this study was to clarify the effect of flexion contracture on component angles. MATERIALS AND METHODS: Thirty-five fixed-bearing UKAs using the spacer block technique with preoperative flexion contracture (Group FC) and 35 UKAs using the same technique without preoperative flexion contracture (Group NC) were included. Using radiographs, the coronal femoral component angle, coronal tibial component angle, sagittal femoral component angle, and sagittal tibial component angle were determined. Also, extension and flexion angles of the knee as well as coronal Hip-Knee-Ankle (HKA) angles in long-leg standing radiographs were measured. The data about the thickness of the selected insert were also collected. The above results were compared between the two groups. RESULTS: The femoral component tended to be placed in a more varus and flexed position in Group FC, while no significant difference was found about the tibial component angles. While there was no significant difference in pre- and postoperative knee flexion angles between the two groups, flexion contracture remained postoperatively in Group FC. Preoperative HKA angle was greater in Group FC while the difference was no longer significant postoperatively. Regarding the thickness of the selected insert, thicker inserts tended to be used in Group FC. CONCLUSIONS: In fixed-bearing UKA with the spacer block technique, the femoral component tended to be placed in a flexed and varus position in the knees with preoperative flexion contracture.


Subject(s)
Arthroplasty, Replacement, Knee , Contracture , Knee Joint , Range of Motion, Articular , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/adverse effects , Female , Contracture/etiology , Contracture/physiopathology , Contracture/surgery , Contracture/diagnostic imaging , Male , Aged , Knee Joint/physiopathology , Knee Joint/surgery , Knee Joint/diagnostic imaging , Middle Aged , Radiography/methods , Knee Prosthesis , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/physiopathology , Preoperative Period
3.
Arch Orthop Trauma Surg ; 144(5): 2429-2435, 2024 May.
Article in English | MEDLINE | ID: mdl-38661997

ABSTRACT

INTRODUCTION: Correct cup placement in total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH) is considerably difficult. This study aimed to analyze the orientation accuracy of cup insertion during THA using a portable navigation system in patients with DDH. MATERIALS AND METHODS: In this retrospective cohort study, we analyzed data from 64 patients who underwent THA using infrared stereo camera-matching portable navigation. Patients underwent THA via the anterolateral approach in the lateral decubitus position. Navigation records for intraoperative cup angles, postoperative cup angles measured on computed tomography (CT) images, and cup angle measurement differences were measured and compared between patients with non-DDH/mild DDH and severe DDH. Furthermore, the predictive factors for outliers of accurate acetabular cup placement were analyzed. RESULTS: The average measurement absolute abduction differences (postoperative CT-navigation record) were 3.9 ± 3.5° (severe DDH) and 3.3 ± 2.6° (non-DDH/ mild DDH), and the anteversion differences were 4.7 ± 3.4° (severe DDH) and 2.3 ± 2.1° (non-DDH/ mild DDH). The anteversion difference was different between the two groups. Multivariate analysis showed that the navigation difference (absolute difference in anteversion between postoperative CT and navigation records of > 5°) was significantly associated with severe DDH (odds ratio [OR]: 3.3; p = 0.049, 95% confidence interval [CI]: 1.0-11.1) and posterior pelvic tilt (OR: 1.1; p = 0.042, 95% CI: 1.0-1.27). CONCLUSIONS: In patients with severe DDH, it is important to pay close attention during THA using portable navigation. However, the average difference was < 5º even in patients with severe DDH, and the accuracy may be acceptable in a clinical setting when the cost is considered.


Subject(s)
Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Retrospective Studies , Female , Male , Developmental Dysplasia of the Hip/surgery , Developmental Dysplasia of the Hip/diagnostic imaging , Middle Aged , Aged , Tomography, X-Ray Computed , Surgical Navigation Systems , Adult , Surgery, Computer-Assisted/methods , Hip Prosthesis
4.
Indian J Orthop ; 58(3): 308-315, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38425826

ABSTRACT

Background: Total knee arthroplasty (TKA) for Charcot arthropathy of the knee is considered controversial because of its higher complication rate compared with that of TKA for osteoarthritis. In this study, we investigated the clinical outcomes, survival rates, and complications of primary TKA for Charcot arthropathy. Methods: We conducted a retrospective analysis of nine patients (12 knees) with Charcot arthropathy who underwent TKA. The mean age of the patients was 63.9 ± 9.4 years (range, 52-83 years). The most frequent causative disease was diabetes mellitus (three patients). Patients' clinical outcomes, including the 2011 Knee Society Score and the range of motion, were compared between preoperative and the most recent postoperative data. The 5- and 10-year survival rates for aseptic revision, revision due to infection, and complications were examined. The mean follow-up period was 7.3 ± 3.9 years (range, 3-14 years). Results: The 2011 Knee Society Score and the knee flexion angle significantly improved after TKA surgery (P < 0.05). The 5-year survival rates for aseptic revision, revision due to infection, and complications were 100%, 91.7%, and 83.3%, respectively; the 10-year survival rates for these parameters were the same. One patient underwent revision for insert replacement due to periprosthetic infection, and the other patient had varus/valgus instability due to soft tissue loosening. Conclusions: The mid- to long-term results of TKA for Charcot arthropathy were generally favorable. Our findings indicate that TKA may be a viable treatment option for Charcot arthropathy.

5.
J Knee Surg ; 37(6): 409-415, 2024 May.
Article in English | MEDLINE | ID: mdl-37788675

ABSTRACT

The alignment philosophy in total knee arthroplasty (TKA) has tended to shift from the gold standard of mechanically aligned technique to personalized alignment, such as the kinematically aligned (KA) technique. However, the influences of different surgical techniques on lower limb alignment relative to the ground are not fully investigated. This study investigated the influence of the ankle and hindlimb alignment change after mechanically aligned TKA and KA-TKA. The varus osteoarthritic patients who underwent TKAs were divided into a mechanically aligned TKA group (group M, n = 50) and a KA-TKA group (group K, n = 50). Radiographic parameters (hip-knee-calcaneus [HKC] angle, hip-knee-ankle [HKA] angle, talar tilt angle [TTA], and tibiocalcaneal angle [TCA]) were investigated using full-length standing radiographs. The deviation angle (ΔTA; angle between the tibial mechanical axis [TMA] and the ground tibial mechanical axis [gTMA]) and the change of ΔTA (cΔTA) were also assessed. These parameters were compared between the two groups, along with the correlation between the preoperative HKA angle and other parameters. ΔTA, TTA, and TCA showed no differences between the groups pre- and postoperatively, and no significant changes were observed postoperatively. The preoperative HKA angle showed a significant negative correlation with cΔTA in both groups (group M: r = -0.33, p = 0.02; group K: r = -0.29, p = 0.04) although no correlation was observed the with preoperative TTA and TCA. Despite no change in ΔTA after surgery, the preoperative varus deformity was associated with a change in the deviation between gTMA and TMA after surgery. A severely varus knee may be inappropriate for ground KA-TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Animals , Arthroplasty, Replacement, Knee/methods , Ankle/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Knee Joint/diagnostic imaging , Knee Joint/surgery , Lower Extremity/surgery , Hindlimb , Retrospective Studies
6.
Osteoarthritis Cartilage ; 32(1): 28-40, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37648149

ABSTRACT

OBJECTIVE: Krüppel-like zinc finger transcription factors (KLFs) play diverse roles in mammalian cell differentiation and development. In this study, we investigated the function of KLF15 in the progression of osteoarthritis (OA). METHODS: 0Destabilization of the medial meniscus (DMM) surgery was performed in 10-week-old male wild-type control (WT) mice and cartilage-specific KLF15 knockout (KO) mice. Histological analysis, immunohistochemistry, and terminal deoxynucleotidyl transferase deoxyuridine triphosphate nick-end labeling staining were performed. Morphological changes were measured using microcomputed tomography. Six mice from each group were analyzed (total number of mice analyzed: 60). In vitro, immunofluorescence, quantitative reverse transcription-polymerase chain reaction, and western blot analyses were performed. RESULTS: KLF15 KO DMM mice exhibited significant cartilage degradation compared to WT mice. According to the Osteoarthritis Research Society International cartilage OA-histopathology scoring system, the mean sum score in KLF15 KO mice was significantly higher than that in WT mice at 8 weeks after surgery. Immunohistochemistry results revealed KLF15 KO mice exhibited reduced peroxisome proliferator-activated receptor gamma (PPARγ) expression, increased pIKKα/ß, a disintegrin-like and metalloproteinase with thrombospondin motifs (ADAMTS) 5, and Matrix metalloproteinases (MMP13) expression, and reduced Forkhead box O (FOXO1) and Light chain 3B (LC3B) expression. Inhibition of PPARγ phosphorylation accelerated the effects of interleukin (IL) 1ß-treatment in both KLF15 KO and WT chondrocytes, and activation of PPARγ expression canceled the IL1ß-induced catabolic effects. CONCLUSION: Our results indicated that the OA phenotype of KLF15 KO DMM mice was influenced by reduced PPARγ expression, including enhanced pIKKα/ß, ADAMTS5, and MMP13 expression, reduced autophagy, and increased apoptosis. KLF15 regulation may constitute a possible therapeutic strategy for the treating OA.


Subject(s)
Cartilage, Articular , Osteoarthritis , Animals , Male , Mice , Cartilage, Articular/pathology , Chondrocytes/metabolism , Disease Models, Animal , Kruppel-Like Transcription Factors/genetics , Kruppel-Like Transcription Factors/metabolism , Kruppel-Like Transcription Factors/pharmacology , Mammals/metabolism , Matrix Metalloproteinase 13/genetics , Matrix Metalloproteinase 13/metabolism , Mice, Knockout , Osteoarthritis/metabolism , PPAR gamma/genetics , PPAR gamma/metabolism , X-Ray Microtomography
7.
Int Orthop ; 48(4): 889-897, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38150005

ABSTRACT

PURPOSE: Only a few reports have been published so far on factors that predict postoperative coronal alignment after unicompartmental knee arthroplasty (UKA). The purpose of this study is to clarify the relationship between the arithmetic hip-knee-ankle angle (aHKA) and postoperative coronal alignment after medial fixed-bearing UKA. METHODS: One hundred and one consecutive patients (125 knees) who underwent medial fixed-bearing UKA were assessed. Pre- and postoperative coronal HKA angles, lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and the thickness of the tibial and femoral bone cut were measured. aHKA was calculated as 180° - LDFA + MPTA. Correlations between postoperative HKA angle and aHKA, LDFA, and MPTA were investigated by single regression analysis. After the patients were divided into three groups according to the postoperative HKA angle, i.e., HKA angle > 180°, 175° < HKA angle ≤ 180°, and HKA angle ≤ 175°, aHKA, LDFA, MPTA, preoperative HKA angle, and the thickness of the distal femoral as well as tibial bone cut were compared among the three groups. RESULTS: aHKA and MPTA were positively correlated with postoperative HKA angle, while no correlation was found between postoperative HKA angle and LDFA. Among the three groups classified by postoperative HKA angle, significant differences were found in aHKA, MPTA, and preoperative HKA angle, while no significant difference was found in LDFA and the amount of distal femoral and tibial osteotomies. CONCLUSIONS: aHKA was correlated with postoperative HKA angle after medial fixed-bearing UKA, which was probably due to the influence of MPTA.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/adverse effects , Ankle/surgery , Osteoarthritis, Knee/surgery , Knee Joint/diagnostic imaging , Knee Joint/surgery , Knee Joint/anatomy & histology , Lower Extremity/surgery , Retrospective Studies , Tibia/diagnostic imaging , Tibia/surgery
8.
Cureus ; 15(11): e48295, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38058331

ABSTRACT

Charcot arthropathy is a rapidly progressive and destructive form of arthropathy caused by various neurological diseases. Total hip arthroplasty (THA) is usually contraindicated in patients with Charcot arthropathy; however, recent studies have reported good results following THA in this patient population. Herein, we report a case of Charcot arthropathy secondary to syphilis in a patient who was successfully treated with constrained THA, a new type of THA. A 56-year-old man was injured in a car accident, and a displaced acetabular fracture was revealed three weeks later. He was treated conservatively but soon developed greater displacement of the fracture and femoral head destruction. The patient was referred to our hospital for further treatment. The patient had pelvic pseudarthrosis secondary to Charcot arthropathy at the time of the first visit to our hospital. First, THA was performed with the acetabular reconstruction of the deficient bone. However, the acetabular implant was displaced one week postoperatively. THA revision was performed using a constrained cup. Postoperatively, the patient exhibited good hip stability without dislocation. However, displacement of the acetabular cup occurred one year after the second surgery. We performed a re-revision of THA using a new type of constrained cup that offers a high level of constraint to maintain range of motion (ROM) and prevent dislocations. The patient was able to walk with a T-cane one year postoperatively. Herein, we report a difficult case of revision THA in a patient with Charcot arthropathy concomitant with syphilis. THA is usually contraindicated in patients with Charcot arthropathy; however, we propose that THA using constrained cups that offer a wider ROM may be a useful therapeutic strategy for the treatment of Charcot arthropathy.

9.
Am J Case Rep ; 24: e941187, 2023 Nov 13.
Article in English | MEDLINE | ID: mdl-37956116

ABSTRACT

BACKGROUND Distal femoral and proximal tibial fractures often lead to nonunion and post-traumatic osteoarthritis, and total knee arthroplasty (TKA) has emerged as an effective alternative for older patients. This report includes 3 cases of successful TKA treatment. The cases involve a 42-year-old man and a 62-year-old man with Hoffa coronal fractures of the distal femur, and a 50-year-old man with a proximal tibial fracture. These patients underwent multiple osteosynthesis procedures before receiving TKA. CASE REPORT Case 1: A 42-year-old man with a displaced Hoffa's fracture had persistent knee pain. Nonunion post-initial fixation led to reoperation with iliac bone grafting and plate fixation. TKA using a Posterior Stabilized (PS)-type implant resulted in improved motion and function after 3 years. Case 2: A 62-year-old man suffered lateral condyle and ligament injuries from a displaced Hoffa's fracture. Despite plate fixation, dislocation occurred, requiring conversion. TKA with long-stem hinge-type implant, using augmentation block, led to enhanced stability and outcomes at 2 years. Case 3: A 50-year-old man's tibial nonunion, treated with plate fixation, resulted in infection and bone fusion. TKA using a constrained PS-type implant insert addressed the lateral tibial adhesions via iliotibial band (ITB) release and treated severe tibial plateau damage. Positive results were seen at 1 year. CONCLUSIONS The challenges of pseudarthrosis, like bone defects and compromised tissue, highlight the need for precise implant selection based on evaluations of bone quality, defects, knee stability, and hyperextension, rather than resorting to overly-constrained implants.


Subject(s)
Arthroplasty, Replacement, Knee , Femoral Fractures , Hoffa Fracture , Tibial Fractures , Male , Humans , Adult , Middle Aged , Femoral Fractures/surgery , Fracture Fixation, Internal/methods , Knee Joint/surgery , Tibial Fractures/surgery
10.
Epilepsia Open ; 8(4): 1369-1382, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37547978

ABSTRACT

OBJECTIVE: Perampanel is an oral anti-seizure medication, which is approved in Japan for focal-onset seizures, with/without focal to bilateral tonic-clonic seizures, as monotherapy/adjunctive therapy in patients aged 4 years and older. Treatment for generalized tonic-clonic seizures as adjunctive therapy in patients aged 12 years and older is approved as well. We evaluated the feasibility of intravenous (IV) administration of perampanel as an alternative to oral administration. METHODS: Study 240 (NCT03754582) was an uncontrolled, open-label study of IV perampanel, conducted in 21 Japanese patients with epilepsy who received a stable dose of 8-12 mg/day of oral perampanel. Patients received 30-minute IV infusions at equivalent daily doses of oral perampanel for 4 days, then were switched back to oral perampanel. Safety, tolerability, plasma concentration, and maintenance of efficacy throughout the transition between IV and oral dosing of perampanel were assessed. As supportive data, a subgroup analysis was also conducted using data from healthy Japanese subjects (n = 18) who were enrolled in Study 050 (NCT03376997) investigating the pharmacokinetics and safety of IV perampanel in healthy subjects who received an IV infusion (30-, 60-, or 90-minute) of perampanel 12 mg and a single oral administration of perampanel 12-mg tablet. RESULTS: In Study 240, the transition between 30-minute IV and oral perampanel dosing was associated with a ≤1.4-fold increase in the mean change in maximum observed concentration of perampanel. Seizure outcomes demonstrated no considerable changes in efficacy before, during, or after 30-minute IV dosing of perampanel. The safety profiles were similar between IV and oral formulations. In Study 050, the pharmacokinetics of 30- or 60-minute IV infusion of perampanel further support the interchangeability between oral and IV formulations in the Japanese subjects. SIGNIFICANCE: These results support that 30-minute IV perampanel may be a potential short-term alternative to oral formulations for patients with epilepsy.


Subject(s)
Anticonvulsants , East Asian People , Epilepsy , Humans , Anticonvulsants/administration & dosage , Epilepsy/drug therapy , Treatment Outcome , Administration, Intravenous
11.
Int Orthop ; 47(11): 2767-2772, 2023 11.
Article in English | MEDLINE | ID: mdl-37572119

ABSTRACT

PURPOSE: The load-bearing pattern of periprosthetic bone may differ between patients who underwent simultaneous bilateral and unilateral total hip arthroplasty (THA). We investigated the differences in periprosthetic bone remodeling after simultaneous bilateral total hip arthroplasty and unilateral total hip arthroplasty. METHODS: This retrospective cohort study enrolled 154 consecutive patients undergoing THA using full hydroxyapatite (HA) compaction short stems. Patient characteristics including age, body mass index, University of California Los Angeles (UCLA) activity score, and bone shape of the proximal femur were adjusted by propensity score matching. Subsequently, periprosthetic bone mineral density changes were compared between simultaneous bilateral and unilateral THA. RESULTS: We found that bone mineral density loss in the simultaneous bilateral THA group was significantly higher in zones 6 and 7 at 24 months after THA (zone 6, p = 0.019; zone 7, p = 0.041). Periprosthetic bone mineral density loss was not associated with clinical factors, including age, body mass index, and daily activity. Additionally, we demonstrated that periprosthetic bone mineral density loss was higher in zones 1, 4, 6, and 7 of patients with a normal hip on the contralateral side after unilateral THA (zone 1, p = 0.041; zone 4, p = 0.041; zone 6, p = 0.037; zone7, p = 0.019). CONCLUSIONS: The postoperative periprosthetic bone remodeling was lower in patients who underwent simultaneous bilateral THA than in those who underwent unilateral THA, even though patient characteristics were adjusted by propensity matching. Further observation of periprosthetic bone mineral density loss is needed to clarify the differences between the groups.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/adverse effects , Cohort Studies , Absorptiometry, Photon , Retrospective Studies , Bone Density , Bone Remodeling , Hip Prosthesis/adverse effects
12.
Arch Orthop Trauma Surg ; 143(12): 7229-7235, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37479832

ABSTRACT

INTRODUCTION: The aim of this study is to compare the accuracy of acetabular cup positioning between the accelerometer-based navigation system and the augmented reality-based navigation system during THA in the supine position. MATERIALS AND METHODS: This retrospective study included 66 patients (70 hips) who underwent THA using two types of portable navigation system, Hip Align or AR-Hip, in the spine position. The absolute difference between the intraoperative navigation record and postoperative measurement using computed tomography data was evaluated. Preoperative clinical factors that decreased the accuracy of cup positioning by ≥ 3° were analyzed via multiple logistic regression analyses. RESULTS: The average absolute error of inclination was 2.8 ± 2.6° in Hip Align and 2.7 ± 1.8° in AR-Hip, and absolute anteversion error was 2.5 ± 2.0° in Hip Align and 2.6 ± 2.2° in AR-Hip, and there was no significantly different between the two navigation systems. There was a significant association between the absolute measurement error (≥ 3°) of cup inclination and patients' BMI in the Hip Align group [odds ratio (OR) 1.350; 95% confidence interval (CI) 1.035-1.760; p = 0.027], but not in the AR-Hip group. CONCLUSIONS: The accuracy of the acetabular cup positioning between the Hip Align and AR-Hip showed no difference during THA in the spine position. The high BMI could have negative influence on the accuracy of cup positioning in THA using Hip Align, thus AR-Hip could be designable for obesity patients.


Subject(s)
Arthroplasty, Replacement, Hip , Augmented Reality , Hip Prosthesis , Surgery, Computer-Assisted , Humans , Arthroplasty, Replacement, Hip/methods , Supine Position , Retrospective Studies , Acetabulum/surgery , Surgery, Computer-Assisted/methods
13.
Stem Cell Rev Rep ; 19(7): 2407-2419, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37477775

ABSTRACT

The stromal-vascular fraction (SVF), comprising heterogeneous cell populations and adipose-derived stromal cells (ADSCs), has therapeutic potential against osteoarthritis (OA); however, the underlying mechanism remains elusive. This study aimed to investigate the therapeutic effects of heterogeneous cells in rabbit SVF on rabbit chondrocytes. Rabbit SVF and ADSCs were autografted into knees at OA onset. The SVF (1 × 105) and low-dose ADSCs (lADSC; 1 × 104) groups adjusted for their stromal cell content were compared. Animals were euthanized 8 and 12 weeks after OA onset for macroscopic and histological analyses of OA progression and synovitis. Immunohistochemical and real-time polymerase chain reaction assessments were conducted. In vitro, immune-fluorescent double staining was performed for SVF to stain macrophages with F4/80, CD86(M1), and CD163(M2). OA progression was markedly suppressed, and synovitis was reduced in the SVF groups (OARSI histological score 8 W: 6.8 ± 0.75 vs. 3.8 ± 0.75, p = 0.001; 12 W: 8.8 ± 0.4 vs. 5.4 ± 0.49, p = 0.0002). The SVF groups had higher expression of collagen II and SOX9 in cartilage and TGF-ß and IL-10 in the synovium, lower expression of MMP-13, and lower macrophage M1/M2 ratio than the lADSC groups. Immunofluorescent double staining revealed a markedly higher number of M2 than that of M1 macrophages in the SVF. The therapeutic effects of SVF on chondrocytes were superior than those of lADSCs, with enhanced anabolic and inhibited catabolic factors. Heterogeneous cells, mainly M2 macrophages in the SVF, enhanced growth factor secretion and chondrocyte-protective cytokines, thus benefiting chondrocytes and knee joint homeostasis. Overall, the SVF is a safe, relatively simple, and a useful treatment option for OA.

14.
Am J Case Rep ; 24: e938905, 2023 Apr 17.
Article in English | MEDLINE | ID: mdl-37062911

ABSTRACT

BACKGROUND Periprosthetic joint infection is a difficult complication, especially in patients with rheumatoid arthritis. Life-threatening septic shock due to periprosthetic joint infection caused by group G streptococcus is rare, and there have been few reports about its treatment. We describe a successful case of sudden onset septic shock due to group G Streptococcus infection after revision total knee arthroplasty. CASE REPORT A 61-year-old woman with rheumatoid arthritis treated with biological disease-modifying antirheumatic drugs for about 12 years presented with acute right knee pain and shock 6 months after revision total knee arthroplasty. Periprosthetic joint infection caused by group G Streptococcus was diagnosed. She was admitted to the Intensive Care Unit, treated with respiratory support and dialysis, and underwent irrigation, debridement, and polyethylene liner exchange as the first surgery. At 9 days after the first surgery, she underwent the second surgery, consisting of implant removal and antibiotic spacer placement due to failure. It took approximately 7 weeks to normalize the levels of systemic markers of inflammation with intravenous antibiotics and then oral antibiotics for further 12 weeks, but re-revision total knee arthroplasty was successfully performed 1.5 years later. At a 1-year follow-up from the final surgery, she was able to walk with a cane and had no symptoms of infection. CONCLUSIONS In such cases with sudden onset of septic shock due to periprosthetic joint infection, appropriate and prompt surgical treatment should be performed to save the infected limb as well as the patient's life.


Subject(s)
Arthritis, Infectious , Arthritis, Rheumatoid , Arthroplasty, Replacement, Knee , Prosthesis-Related Infections , Shock, Septic , Shock , Streptococcal Infections , Female , Humans , Middle Aged , Arthroplasty, Replacement, Knee/adverse effects , Shock, Septic/complications , Prosthesis-Related Infections/drug therapy , Treatment Outcome , Retrospective Studies , Renal Dialysis/adverse effects , Streptococcal Infections/etiology , Streptococcal Infections/complications , Arthritis, Infectious/etiology , Arthritis, Infectious/drug therapy , Debridement , Reoperation/adverse effects , Anti-Bacterial Agents/therapeutic use , Arthritis, Rheumatoid/drug therapy
15.
Int Orthop ; 47(9): 2215-2223, 2023 09.
Article in English | MEDLINE | ID: mdl-37086287

ABSTRACT

PURPOSE: This study aimed to evaluate kinematically aligned total knee arthroplasty (KA-TKA) targeting the neutral ground mechanical axis (MA) (hip-to-calcaneus axis), the line from the hip centre to the bottom of the calcaneus, (ground KA-TKA) in terms of its comparison with tibia-restricted modified KA-TKA (modified KA-TKA). METHODS: This retrospective cohort study included 106 consecutive patients who underwent unilateral KA-TKA for varus osteoarthritis (OA) (60 modified KA-TKAs and 46 ground KA-TKAs). After 1:1 propensity score matching, 60 patients (30 pairs) were matched between the groups with comparable demographic data. The hip-knee-ankle (HKA) angle, coronal femoral component alignment (FCA), and coronal tibial component alignment (TCA) were compared between groups. Intraoperative soft tissue balance, including the joint component gap and varus/valgus balance, was also compared between the groups. One year postoperatively, the clinical outcomes, including the range of motion and 2011 Knee Society Score, were compared between groups. RESULTS: The HKA angle and FCA/TCA were not significantly different between groups. Whereas the varus/valgus balance showed no significant differences between groups, smaller joint component gaps were found throughout the range of motion in the ground KA-TKA group than in the modified KA-TKA group. Despite no difference in clinical scores between groups, a significantly deeper postoperative flexion angle was achieved in the ground KA-TKA group than in the modified KA-TKA group (p < 0.05). CONCLUSION: Targeting neutral ground MA in KA-TKA for patients with varus OA has the potential to provide a better flexion angle with stable intraoperative soft tissue balance.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Retrospective Studies , Biomechanical Phenomena , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Range of Motion, Articular
16.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3880-3888, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36918435

ABSTRACT

PURPOSE: Assessment of the conventional mechanical axis (MA) (hip-to-talus axis) is reported to result in constitutional varus in the native knee. However, the ground MA (hip-to-calcaneus axis), which is the line from the hip center to the bottom of the calcaneus, passes through the center of the knee joint in the native knee and is a possible alternative target for total knee arthroplasty (TKA) assessments. Therefore, this study aimed to present a "ground kinematically aligned (KA)-TKA." In this technique, the femoral component is placed on the cylindrical axis using the calipered technique and the tibial component is placed to give a neutral ground MA. Radiographical investigation was used to determine whether physiological alignment can be individually achieved with ground KA-TKA; this was compared with that of a tibia-restricted modified KA-TKA, referring to conventional MA (hip-to-talus axis) results. METHODS: As the primary endpoint, this prospective cohort study compared the ground MA ratios of the knee joints in 40 ground KA-TKAs (G group: Coronal Plain Alignment of the Knee (CPAK) 28 type I, 7 II, 1 IV, and 4 V) with those of the preceding 60 modified KA-TKAs (M group: CPAK 46 type I, 12 II, and 2 V) performed for patients with varus osteoarthritis (OA). The number of outliers differing over ± 5% from the neutral were compared between groups using the χ2-test. The Hip-knee-ankle (HKA) angle, coronal femoral/tibial component alignment (FCA/TCA), and joint line orientation angle (JLOA) were compared between the groups using non-paired t-tests. Statistical significance was set at p < 0.05. RESULTS: The G group had a higher ratio of the ground MA passing through the knee center than the M group did; outliers differing over ± 5% from the neutral of the ground MA were 2/40 cases in the G group and 20/60 cases in the M group, which was a significant difference (p = 0.001). The HKA angle, FCA/TCA, and JLOA were not significantly different between the groups. CONCLUSIONS: Targeting the ground MA in KA-TKA for patients with varus OA was feasible and has the potential to provide a physiological alignment more similar to the native knee in TKA than other kinematic alignment techniques. LEVEL OF EVIDENCE: Level III.


Subject(s)
Arthroplasty, Replacement, Knee , Calcaneus , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Calcaneus/surgery , Prospective Studies , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Biomechanical Phenomena , Retrospective Studies
17.
Int Orthop ; 47(6): 1473-1480, 2023 06.
Article in English | MEDLINE | ID: mdl-36928553

ABSTRACT

PURPOSE: This study aimed to examine the prosthetic orientations, limb alignment, intraoperative soft tissue balance, and early clinical outcomes associated with the use of the relatively new handheld robot technique compared to those associated with the use of the conventional alignment guide for bi-cruciate stabilized total knee arthroplasty (TKA). METHODS: This retrospective cohort study compared the prosthetic orientation and limb alignment of 35 patients who underwent TKA using robotic assistance (robot group) with those of patients who underwent TKA using a conventional alignment guide (control group). The coronal femoral component alignment (FCA), coronal tibial component alignment (TCA), and the hip-knee-ankle (HKA) angle were compared between groups. Intraoperative soft tissue balance, including the joint component gap and varus/valgus balance assessed by an offset-type tensor, were also compared between groups. One year postoperatively, the clinical outcomes, including the range of motion and 2011 Knee Society Score (KSS), were compared between groups. RESULTS: The HKA angle and FCA were 0.1° varus and 0.1° varus, respectively, in the robot group and 1.3° varus and 1.3° varus, respectively, in the control group. The difference in the HKA angle and the FCA, but not the TCA, between groups was statistically significant (p < 0.05). The intraoperative soft tissue balance showed more stable joint component gaps and varus/valgus balances throughout the range of motion in the robot group than in the control group. Clinical outcomes of the robot group showed superior 2011 KSS subscales compared to those of the control group. CONCLUSION: The accuracy of the implantations and stable soft tissue balance in the robot group were superior to those of the control group. The robot group also had superior patient-reported scores for early clinical outcomes.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Robotics , Humans , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Retrospective Studies , Knee Joint/surgery
18.
Int J Surg Case Rep ; 103: 107853, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36701901

ABSTRACT

INTRODUCTION AND IMPORTANCE: Knee osteoarthritis with femoral and/or tibial extra-articular deformities makes total knee arthroplasty (TKA) technically difficult to perform, especially using intramedullary-based instrumentation systems. The Athena Knee 3-dimensional (3-D) image matching software is effective for TKA with an extra-articular deformity, especially in case of using a long-stem prosthesis or not available computer-assisted navigation systems. CASE PRESENTATION: A 79-year-old woman presented with right knee pain secondary to a progressive valgus deformity and gait disturbance. She had experienced a supracondylar femoral fracture fifteen years ago, and a tibial shaft fracture ten years ago on the same side; both of fractures were treated surgically. She had a severe valgus knee deformity and extra-articular deformity of femur and tibia, and valgus stress test detected medial knee instability. The range of motion was 0° in extension and 75° in flexion. Severe medial knee laxity compelled us to use a constrained and long-stem prosthesis, resulting in the use of an intramedullary guided system. The 3-D software system helped us to determine the amount of bone to cut as well as the appropriate entry points for the intramedullary rods and mechanical axis restoration. At two years after surgery, knee range of motion improved to 90° in flexion, and walking ability had also advanced from the use of two crutches to that of a T cane. CONCLUSION: The 3-D image matching software system for preoperative planning was useful for TKA with extra-articular deformity, especially in the case of a long-stem prosthesis without using a navigation system.

19.
J Knee Surg ; 36(10): 1013-1019, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35817057

ABSTRACT

INTRODUCTION: Kinematically aligned total knee arthroplasty (KA-TKA) has gained interest for achieving more favorable clinical outcomes than mechanically aligned TKA. One of the advantages of KA-TKA is reported to be an easy acquisition of intraoperative soft-tissue balance without excessive medial release for varus osteoarthritis. However, we hypothesized that the prosthesis type affects intraoperative soft-tissue balance even in the KA-TKA. The present study aimed to compare intraoperative soft-tissue balance and clinical outcomes of KA-TKAs using single-radius (SR) or multiradius (MR) prostheses. MATERIALS: AND METHODS: Consecutive 70 cruciate-retaining modified KA-TKAs (31 SR and 39 MR) were performed in patients with varus-type osteoarthritis using a navigation system. Intraoperative soft-tissue balance including joint component gap and varus/valgus balance was measured with femoral component placement and patellofemoral joint reduction throughout the range of motion using offset-type tensor and compared between the two groups. Two years postoperatively, the range of motion and 2011 Knee Society Scores were compared between the two groups. RESULTS AND CONCLUSION: Joint component gaps showed no significant differences between the two groups from 0 to 30 degrees of flexion. However, during 60 to 120 degrees of flexion, joint component gaps of SR group showed significantly larger values than those of MR group (p < 0.05). There were no significant differences in varus/valgus balance throughout the range of motion between the two groups. The postoperative clinical outcomes showed no significant differences between the two groups. INTERPRETATION: Despite no difference in clinical outcomes, joint component gap showed different patterns due to the prosthesis type in modified KA-TKAs.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Biomechanical Phenomena , Range of Motion, Articular
20.
J Knee Surg ; 36(1): 95-104, 2023 Jan.
Article in English | MEDLINE | ID: mdl-33992036

ABSTRACT

Novel medial preserving gap technique (MPGT) focuses on medial compartment stability and allows lateral physiological laxity. This study aimed to compare the MPGT with the measured resection technique (MRT) to determine which provides better postoperative knee stability after posterior-stabilized total knee arthroplasty (PS-TKA). Primary PS-TKA, using either MPGT (n = 65) or MRT (n = 65), was performed in 130 patients with varus knee osteoarthritis. Postoperative knee stabilities at extension and flexion were assessed using varus-valgus stress radiographs and stress epicondylar view, respectively (at 1 month, 6 months, 1 year, and 3 years postoperatively). The distance between the femoral prosthesis and polyethylene insert was measured on each medial and lateral side, defined as the medial joint opening (MJO) and lateral joint opening (LJO), respectively. Decreasing MJO or LJO translated to increasing postoperative stability. The femoral external rotation angle was compared between the two surgical techniques; postoperative knee stability was also compared between the medial and lateral compartments, as well as the surgical techniques. A significant difference was found in the femoral external rotation angle between MPGT (4.2 ± 0.2 degrees) and MRT (3.6 ± 0.1 degrees, p < 0.01). Postoperative MJOs both at extension and flexion were significantly smaller than LJOs using MPGT and MRT at all time points (p < 0.05). MJOs and LJOs at extension using MPGT were significantly smaller than those when using MRT, at 1 and 3 years postoperatively (p < 0.05). Furthermore, MJOs at flexion using MPGT were significantly smaller than those when using MRT at 6 months, 1 year, and 3 years postoperatively (p < 0.05). MPGT provided higher postoperative medial knee stability than MRT both at extension and flexion, even at 3 years after PS-TKA. This suggests that this newly developed surgical technique is a more feasible option than MRT for the preservation of postoperative medial knee stability.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Knee Joint/surgery , Knee/surgery , Range of Motion, Articular/physiology , Biomechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL
...