Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Clin Cardiol ; 36(7): 394-400, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23585345

ABSTRACT

BACKGROUND: The plasma B-type natriuretic peptide (BNP) level has been shown to be increased in patients with chronic atrial fibrillation (AF) independent of left ventricular ejection fraction (LVEF). The purpose of this study is to evaluate the relationship between the plasma BNP level and heart rate variation in patients with AF. HYPOTHESIS: The plasma BNP level is associated with heart rate variation in patients with AF. METHODS: A total of 102 patients with AF and preserved LVEF were included from 2 hospitals. The ambulatory electrocardiographic recording and measurement of plasma BNP levels were performed simultaneously. Echo-Doppler parameters were measured as the average of 10 consecutive cardiac cycles. RESULTS: A difference in the mean heart rate between night and day (DIFF) and the standard deviation of the 5-miniute mean R-R interval (SDARR) were significantly associated with log-transformed BNP levels (r = -0.411, P < 0.001 and r = -0.243, P = 0.049, respectively). In echocardiography, the ratio of E velocity to early diastolic velocity, which reflects left ventricular (LV) filling pressure, was significantly correlated with the DIFF and SDARR, along with the log-transformed BNP level. Stepwise multiple linear regression analysis revealed that the DIFF and age were independent factors related with the BNP level (P < 0.01). CONCLUSIONS: The reduced diurnal variation of heart rate was significantly associated with increased BNP, which is linked to LV diastolic dysfunction in patients with AF.


Subject(s)
Atrial Fibrillation/blood , Atrial Fibrillation/physiopathology , Circadian Rhythm , Heart Rate , Natriuretic Peptide, Brain/blood , Age Factors , Aged , Aged, 80 and over , Atrial Fibrillation/diagnostic imaging , Biomarkers/blood , Cross-Sectional Studies , Down-Regulation , Echocardiography, Doppler , Electrocardiography, Ambulatory , Female , Humans , Japan , Linear Models , Male , Middle Aged , Multivariate Analysis , Risk Factors , Stroke Volume , Time Factors , Up-Regulation , Ventricular Dysfunction, Left/blood , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left
2.
Intern Med ; 50(16): 1621-9, 2011.
Article in English | MEDLINE | ID: mdl-21841318

ABSTRACT

BACKGROUND: Even high-normal albuminuria is reportedly associated with cardiovascular events. OBJECTIVE: We determined the urine albumin creatinine ratio (UACR) in spot urine samples and analyzed the UACR distribution and the prevalence of high-normal levels. PATIENTS AND METHODS: The UACR was determined using immunoturbidimetry in 332 untreated asymptomatic non-diabetic Japanese patients with hypertension and in 69 control subjects. The microalbuminuria and macroalbuminuria levels were defined as a UCAR ≥30 and <300 µg/mg·creatinine and a UCAR ≥300 µg/mg·creatinine, respectively. RESULTS: The distribution patterns showed a highly skewed distribution for the lower levels, and a common logarithmic transformation produced a close fit to a Gaussian distribution with median, 25th and 75th percentile values of 22.6, 13.5 and 48.2 µg/mg·creatinine, respectively. When a high-normal UACR was set at >20 to <30 µg/mg·creatinine, 19.9% (66/332) of the hypertensive patients exhibited a high-normal UACR. Microalbuminuria and macroalbuminuria were observed in 36.1% (120/336) and 2.1% (7/332) of the patients, respectively. UACR was significantly correlated with the systolic and diastolic blood pressures and the pulse pressure. A stepwise multivariate analysis revealed that these pressures as well as age were independent factors that increased UACR. CONCLUSION: The UACR distribution exhibited a highly skewed pattern, with approximately 60% of untreated, non-diabetic hypertensive patients exhibiting a high-normal or larger UACR. Both hypertension and age are independent risk factors that increase the UACR. The present study indicated that a considerable percentage of patients require anti-hypertensive drugs with antiproteinuric effects at the start of treatment.


Subject(s)
Albuminuria/epidemiology , Albuminuria/urine , Creatinine/urine , Diabetes Mellitus , Hypertension/epidemiology , Hypertension/urine , Adult , Aged , Albuminuria/diagnosis , Biomarkers/urine , Female , Humans , Hypertension/diagnosis , Male , Middle Aged , Prevalence
3.
Clin Drug Investig ; 30(10): 699-706, 2010.
Article in English | MEDLINE | ID: mdl-20701401

ABSTRACT

BACKGROUND: High-normal urinary albumin excretion has been reported to have clinical significance with respect to progression of proteinuria and hypertension. OBJECTIVE: We analysed the effect of cilnidipine (10 mg/day) on morning systolic blood pressure (SBP) and urine albumin-creatinine ratio (UACR) in 16 non-diabetic hypertensive patients with a normal to marginally elevated UACR (mean +/- SD 29.4 +/- 21.7; range 7.5-72.9 mg/g creatinine). METHODS: Sequential home BP and UACR data were fitted to a simple exponential function as follows: where y is SBP (mmHg) or UACR (mg/g creatinine); alpha is the extent of the SBP (mmHg)- or UACR (mg/g creatinine)-lowering effect; beta (days) is the time-constant for SBP or UACR decrease; t is the number of days after the start of cilnidipine administration; and gamma is the finally stabilized SBP (mmHg) or UACR (mg/g creatinine). RESULTS: Mean +/- SD morning SBP and UACR decreased by 20.4 +/- 11.4 mmHg and 15.2 +/- 13.1 mg/g creatinine, respectively, as determined by coefficient alpha. The mean +/- SD time-constant for UACR decrease was significantly longer than that for BP decrease (43.5 +/- 22.9 vs 15.4 +/- 7.1 days). UACR reduction correlated with pre-treatment UACR values (correlation coefficient [R] = 0.88, p < 0.01) but not with BP decrease. CONCLUSIONS: The present study demonstrated that cilnidipine reduced UACR in hypertensive patients with normal to marginally elevated UACR independent of its BP-lowering effect.


Subject(s)
Albuminuria/drug therapy , Antihypertensive Agents/therapeutic use , Calcium Channel Blockers/therapeutic use , Creatinine/urine , Dihydropyridines/therapeutic use , Hypertension/drug therapy , Models, Statistical , Albuminuria/etiology , Albuminuria/urine , Antihypertensive Agents/adverse effects , Biomarkers/urine , Blood Pressure/drug effects , Blood Pressure Monitoring, Ambulatory , Calcium Channel Blockers/adverse effects , Dihydropyridines/adverse effects , Humans , Hypertension/complications , Hypertension/physiopathology , Nephelometry and Turbidimetry , Time Factors , Treatment Outcome
4.
Heart Rhythm ; 6(8): 1163-9, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19632628

ABSTRACT

BACKGROUND: Repolarization abnormality, especially during bradycardia, might be critical for initiation of ventricular fibrillation (VF) in patients with Brugada syndrome (BrS), but the contribution of the rate-dependent repolarization dynamics to the occurrence of VF is still unknown. OBJECTIVE: The aim of our study was to determine the differences in rate-dependent repolarization dynamics between BrS with and without spontaneous VF and between BrS with and without SCN5A mutation. METHODS: The subjects were 37 BrS patients with VF (VF(+) group: 10 male subjects) and without VF (VF(-) group: 27 male subjects) and 20 control subjects. Genetic analysis of SCN5A was performed in all 37 BrS patients. The relationships between QT, QTp, Tp-e, and RR intervals were obtained from Holter recordings as first linear regression lines, and the slopes of QT/RR, QTp/RR, and Tp-e/RR linear regression lines as the sensitivity of rate-dependent repolarization dynamics were compared. RESULTS: QT/RR and Tp-e/RR slopes showed loss of a rate-dependent property in the VF(+) group compared with those in the VF(-) and control groups. There was no significant difference in QTp/RR slope among the VF(+), VF(-) and control groups. The Tp-e interval had a negative correlation with the RR interval in the VF(+) group and a positive correlation with the RR interval in the VF(-) and control groups. There was no significant difference in QT/RR, QTp/RR, and Tp-e/RR slopes between BrS patients with SCN5A mutation and those without SCN5A mutation. CONCLUSIONS: Loss of rate-dependent QT dynamics may be associated with occurrence of VF in BrS.


Subject(s)
Brugada Syndrome/physiopathology , Muscle Proteins/genetics , Sodium Channels/genetics , Adult , Aged , Analysis of Variance , Brugada Syndrome/diagnosis , Brugada Syndrome/genetics , Case-Control Studies , Electrocardiography, Ambulatory , Humans , Male , Middle Aged , NAV1.5 Voltage-Gated Sodium Channel , Statistics as Topic , Ventricular Fibrillation/genetics , Ventricular Fibrillation/physiopathology
5.
Clin Exp Hypertens ; 30(3): 191-201, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18425699

ABSTRACT

We examined the hemodynamic responses to exercise and symptoms in 37 male patients with untreated essential hypertension, and compared the findings with those in 32 age-matched healthy male volunteers by performing a graded symptom-limited exercise test using a bicycle ergometer. The subjective feeling of intensity of exercise was determined using the Borg scale. In the relationship between Borg scores and blood pressure (BP), patients with hypertension showed higher systolic BP and diastolic BP relative to the Borg scores than the controls. Consequently, patients with hypertension showed significantly higher systolic BP with Borg scores < or = 3 (subjective symptoms < or = moderately hard) than the controls (177.8 +/- 27.0 vs. 143.7 +/- 17.9 mmHg, p < 0.0001). Similarly, significantly higher diastolic BP with Borg scores < or = 3 was observed in patients with hypertension than in the controls (101.6 +/- 12.0 vs. 82.6 +/- 11.6 mmHg, p < 0.0001). The pulse pressure with Borg scores < or = 3 was also significantly higher in patients with hypertension than in the controls (76.2 +/- 20.6 vs. 61.0 +/- 13.6 mmHg, p < 0.0001). Hypertensive patients showed a decrease in the high-frequency power of heart rate variability at initial low-load exercise. In conclusion, the present study revealed that there was a greater BP response relative to the Borg score in patients with hypertension than in the controls. Autonomic nerve activity may contribute to some extent to these different relations. A determination of the relationship between the subjective feeling of intensity of the exercise and BP levels caused by a given intensity of load is essential before exercise training in patients, at least in males, with hypertension to avoid increasing the risk of cardiovascular events in association with excessive exercise training.


Subject(s)
Blood Pressure , Exercise , Hypertension/physiopathology , Hypertension/psychology , Exercise Test , Heart Rate , Hemodynamics , Humans , Male , Middle Aged , Psychophysics/methods , Self-Assessment
6.
Heart Vessels ; 23(1): 53-9, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18273547

ABSTRACT

Measurement of heart rate variability (HRV) is useful in assessing the function of the autonomic nervous system and in staging of clinical diseases. The purpose of this study is to assess a feasibility of HRV for evaluating surgical stress during the noncardiac perioperative period. Standard deviation of normal-to-normal RR intervals (SDNN) and HRV triangular index derived from 24-h Holter ECC were measured in 24 patients undergoing digestive surgery. Holter ECG was performed at 1 day before operation, the first day (postoperative day 1: POD1), and the 7th day (POD7) after operation. Indices of HRV were compared with factors influencing surgical stress, such as duration of the operation and amount of blood loss during the operation, and postoperative complications. The SDNN and HRV triangular index decreased significantly on POD1 and recovered on POD7 (P < 0.05). Heart rate variability indices correlated significantly to duration and blood loss of operation (both P < 0.05). In 7 patients with postoperative complications, HRV indices were statistically lower than those in patients without complications on POD1 (P < 0.05). Our results indicate that HRV may provide useful information with respect to surgical stress.


Subject(s)
Circadian Rhythm/physiology , Digestive System Surgical Procedures , Heart Rate/physiology , Postoperative Complications/physiopathology , Stress, Mechanical , Adult , Aged , Aged, 80 and over , Electrocardiography, Ambulatory , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prognosis , Retrospective Studies
7.
J Hypertens ; 26(3): 535-43, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18300866

ABSTRACT

OBJECTIVES: The augmentation index of the radial pulse wave has been reported to be a sensitive aortic stiffness marker in relatively young but not in older individuals. We studied the relationship between augmentation index and the diurnal blood pressure profiles. PATIENTS AND METHODS: Twenty-four-hour ambulatory blood pressure monitoring was performed in 90 untreated patients with uncomplicated essential hypertension. The patients were classified into four groups: dippers, extreme dippers, nondippers, and risers. Augmentation index was calculated as the percentage of the second systolic peak relative to the first systolic peak. RESULTS: No significant differences in the averaged whole 24-h systolic or diastolic blood pressure were observed in the whole set of patients or in subgroup patients with age 60 years or under. In the whole set of patients (58.7 +/- 12.9 years), there were significant differences in augmentation index between patients with abnormal (other than dippers) and normal diurnal blood pressure profiles (dippers). In subgroup patients with age 60 years or below (49.1 +/- 9.1 years, n = 48), the abnormal diurnal blood pressure profile group showed significantly higher augmentation index (89.6 +/- 10.3%) than dippers (80.5 +/- 11.8%). The area under the curve in the receiver operating characteristics curve for distinguishing between dippers than other dippers was 0.73 (P < 0.01). Multivariate analysis demonstrated that abnormal diurnal blood pressure profile was independently associated with increase in augmentation index. In contrast, these relationships were not significant in the over 60 years subgroup patients (69.8 +/- 5.6 years old, n = 42). CONCLUSIONS: The present study revealed that augmentation index was associated with dipping blood pressure patterns in untreated hypertensive patients aged 60 years or younger. Augmentation index determination would be useful for initial assessment in connection with possible abnormal diurnal blood pressure variability in patients with age 60 years or younger.


Subject(s)
Blood Pressure/physiology , Hypertension/diagnosis , Hypertension/physiopathology , Radial Artery/physiopathology , Area Under Curve , Circadian Rhythm , Female , Humans , Male , Middle Aged , Monitoring, Ambulatory , Sensitivity and Specificity
8.
Clin Exp Hypertens ; 30(1): 45-55, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18214733

ABSTRACT

Heart rate variability (HRV) has recently been used to detect autonomic nerve tone, which is affected by various stresses. To test out hypothesis that HRV can determine surgical stress, we examined perioperative HRV in 30 patients with surgical treatment. Relations between HRV and factors of surgical stresses, such as duration of the operation, amount of blood loss at the operation, and developments of complications, were evaluated. Mean heart rate (HR) increased and other HRV indices decreased postoperatively. Most indices correlated significantly to the duration of the operation and amount of blood loss at the operation on postoperative day 1. Only the standard deviation of normal to normal RR intervals (SDNN) and HRV triangular index showed significantly low values in complicated patients. HRV measurement in the perioperative period showed a significant relation to surgical stress. The present results indicated that HRV may provide useful information with respect to surgical stress.


Subject(s)
Digestive System Surgical Procedures/statistics & numerical data , Heart Rate , Postoperative Complications/epidemiology , Stress, Physiological/physiopathology , Aged , Blood Loss, Surgical , Electrocardiography, Ambulatory , Female , Humans , Male , Middle Aged , Perioperative Care
9.
Hypertens Res ; 30(7): 651-8, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17785934

ABSTRACT

We examined the relationship between plasma B-type natriuretic peptide (BNP) level and diurnal variability pattern of blood pressure (BP). Twenty-four-hour ambulatory BP monitoring was performed in 98 patients with asymptomatic essential hypertension, and the patients were classified into four groups according to their circadian BP variation profiles: dippers (n=29), nondippers (n=36), extreme dippers (n=19), and risers (n=14). Plasma BNP was measured by enzyme immunoassay. Based on the distribution pattern of BNP values, the values were analyzed after logarithmic transformation. Significant differences in plasma BNP levels among the types of circadian BP variations were demonstrated by analysis of variance (p<0.0005). Nondippers and risers showed significantly higher plasma BNP levels (mean [range: -1 SD and +1 SD]: 16.1 [6.3, 41.6] pg/mL and 29.2 [15.9, 53.4] pg/mL, respectively) than dippers (8.4 [3.7, 19.1] pg/mL). The area under the receiver operating characteristics curve for distinguishing patients with abnormal circadian BP variation from those with normal variation was 0.72, indicating that plasma BNP levels were useful for distinguishing between these patients. Specificity of 69% and sensitivity of 72% were obtained with a cut-off value of 10.5 pg/mL (log plasma BNP, 1.02) for distinguishing the abnormal diurnal BP profile group from the normal group. In conclusion, hypertensive patients with abnormal diurnal BP variation patterns (nondippers, extreme dippers, and risers) showed higher plasma BNP levels than those with normal circadian BP variation (dippers). Plasma BNP level is clinically useful for the identification of hypertensive patients who have abnormal circadian BP variability, which increases the risk of cardiovascular events.


Subject(s)
Blood Pressure/physiology , Circadian Rhythm/physiology , Hypertension/blood , Hypertension/diagnosis , Natriuretic Peptide, Brain/blood , Adult , Aged , Biomarkers/blood , Blood Pressure Monitoring, Ambulatory , Electrocardiography , Female , Humans , Hypertension/physiopathology , Male , Middle Aged , Sensitivity and Specificity
10.
J Med Ultrason (2001) ; 34(1): 37-42, 2007 Mar.
Article in English | MEDLINE | ID: mdl-27278178

ABSTRACT

PURPOSE: Automatic Doppler flow signal detection systems can provide beat-to-beat information for large blood vessels. We have developed new equipment for automatic measurement of Doppler flow signals. The reliability of the system was examined, and the variability of aortic and pulmonary peak flow velocity was determined. METHODS: We measured peak flow velocity using a newly developed system in healthy volunteers and patients with atrial fibrillation. Analysis of variability of peak flow velocity was performed with maximal entropy methods. RESULTS: In Bland-Altman plots, the mean and standard deviation (SD) of differences in aortic peak flow velocities between the automatic and manual measurements were 0.22 ± 0.75 cm/s and 0.85 ± 0.38 cm/s, respectively, in five normal volunteers. Moreover, less than 5% of the plotted points were beyond ± 2 SD of the differences. Furthermore, good reproducibility was demonstrated using Bland-Altman plots and Pearson's correlation analysis. Identical reliability was obtained in patients with atrial fibrillation. The same results were obtained for pulmonary peak flow velocity. In five healthy subjects, aortic and pulmonary peak flow showed standard deviations of 7.2 ± 2.4 and 3.8 ± 0.6 cm/s, respectively, and coefficients of variation of 6.1% ± 1.0% and 5.1% ± 1.1%, respectively, in time-domain variability. Similarly, frequency-domain variability was obtained for both peak flow velocities. CONCLUSION: The present study demonstrated the reliability of a newly developed automatic Doppler flow signal detection system. Using this system, the present study demonstrated for the first time aortic and pulmonary peak flow velocity variability. The present analytical methods may have considerable potential for studying aortic and/or pulmonary flow variability in connection with cardiac performance and prognosis of cardiac disease.

11.
Clin Exp Hypertens ; 25(3): 145-54, 2003 Apr.
Article in English | MEDLINE | ID: mdl-12716077

ABSTRACT

Blood pressure (BP) decay data obtained from homeBP measurements in six patients with uncomplicated essential hypertension treated with a calcium blocker, amlodipine, were fitted to an exponential-exponential cosine function to determine the characteristic BP-lowering effects of amlodipine. An exponential-exponential cosine function fitted the morning and night systolic BP (sBP) decay data better than a simple exponential function. From the coefficients of the equation, the estimated BP lowering, time constant for BP decay and BP oscillation induced by amlodipine for morning and night sBP were approximately 23 and 25 mmHg, 10 and 6 days, and 12 and 12 mmHg, respectively. Diastolic BP showed a similar fitting though the fitting was weaker. The fitting results indicate that the BP decay, especially the sBP decay, induced by amlodipine occurred in an oscillative fashion, and the present analysis using home BP data may provide clinically useful information about the characteristic effects of amlodipine.


Subject(s)
Amlodipine/therapeutic use , Blood Pressure Determination/methods , Blood Pressure/drug effects , Calcium Channel Blockers/therapeutic use , Hypertension/drug therapy , Aged , Amlodipine/pharmacology , Blood Pressure/physiology , Calcium Channel Blockers/pharmacology , Female , Humans , Male , Middle Aged , Models, Theoretical , Self Care/methods
12.
Clin Exp Hypertens ; 24(1-2): 11-21, 2002.
Article in English | MEDLINE | ID: mdl-11848164

ABSTRACT

Heart rate (HR) variability is important with respect to disease prognosis and the effects of drugs. Lorenz scatterplots provide a simple way to evaluate HR variability visually. The relation of Lorenz scatterplots to frequency-domain HR variability was examined in 75 Holter recordings and in simulated HR trends. The length of Lorenz scatterplots was double-exponentially correlated with total frequency and very-low frequency powers, with correlation coefficients (r) of 0.88. The width of Lorenz scatterplots was highly correlated with the high frequency power (r=0.98). The sum of the width and length of Lorenz scatterplots was highly correlated with the total frequency power (r=0.92). Identical results were obtained when simulated HR trends were used. In conclusion, Lorenz scatterplots provide a simple way to estimate the frequency-domain HR variability.


Subject(s)
Heart Rate/physiology , Statistics as Topic/methods , Adolescent , Adult , Aged , Aged, 80 and over , Artifacts , Cardiac Output, Low/physiopathology , Computer Simulation , Electrocardiography, Ambulatory , Female , Humans , Hypertension/physiopathology , Male , Middle Aged , Models, Cardiovascular , Myocardial Ischemia/physiopathology , Nonlinear Dynamics , Reference Values
13.
Biomed Pharmacother ; 56 Suppl 2: 353s-358s, 2002.
Article in English | MEDLINE | ID: mdl-12653193

ABSTRACT

Autonomic nerve activity shows circadian variation. Therefore, we put forward the hypothesis that the responses of heart rate (HR) and high-frequency (HF) power of HR variability to exercise would be different between early morning and daytime exercise. We performed ergometer constant load exercise tests [50 watts (low), 100 watts (high load)] in the early morning and during the day in 6 healthy volunteers. The HR response was fitted to an exponential hyperbolic sine function: HR= alpha*e(-beta*t) *sinh(omega*t)+gamma. In this equation, the beta/omega ratio was inversely correlated with the intensity of the HR response. HF power was determined using a recently developed algorithm with high time-resolution power. There were no significant differences in HR, HF power or systolic blood pressure (BP) pressure before exercise between early morning and daytime exercise with either the 50 or 100 watt loads. During exercise, there were no significant differences in maximal HR or maximal systolic BP between early morning and daytime exercise with either 50 or 100 watt loads. For high-load exercise, the beta/omega ratio was significantly lower in early morning exercise (mean +/- SD, 0.945 +/- 0.02) than in daytime exercise (0.987 +/- 0.03). Similarly, for 100 watt exercise, HF power of HR variability was significantly lower in early morning exercise (0.94 +/- 0.52 msec/Hz 1/2) than in daytime exercise (1.26 +/- 0.74 msec/Hz 1/2). In conclusion, the present study demonstrated that a lower beta/omega ratio in the HR response was associated with lower HF power of HR variability in early morning high-load exercise compared to that in daytime exercise, indicating that the heart rate responded more intensely to early morning exercise than to daytime exercise with a high load due, at least partly, to pronounced suppression of parasympathetic nerve activity.


Subject(s)
Circadian Rhythm/physiology , Exercise/physiology , Heart Rate/physiology , Adult , Blood Pressure/physiology , Exercise Test/methods , Exercise Test/statistics & numerical data , Humans , Linear Models , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...