Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Pituitary ; 20(6): 709-710, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28831662

ABSTRACT

Pituitary apoplexy (PA), defined by the occurrence of a massive hemorrhagic necrotic rearrangement within a pituitary adenoma, is rare. Its occurrence can be associated with certain risk factors, including anticoagulation. We report the first case of PA with rivaroxaban which is one of the new oral anticoagulants: a 73 year-old patient presenting with severe headache and visual field deterioration. Surgery was performed. Radiotherapy treatment was decided three months after surgery because of tumor residue.


Subject(s)
Pituitary Apoplexy/diagnosis , Pituitary Apoplexy/drug therapy , Pituitary Neoplasms/complications , Rivaroxaban/therapeutic use , Aged , Humans , Male , Pituitary Apoplexy/etiology
3.
J Dent Res ; 73(12): 1824-32, 1994 Dec.
Article in English | MEDLINE | ID: mdl-7814754

ABSTRACT

The goal of this study was to establish a protocol for the retrieval and fractographic analysis of failed restorations, and to compare the fracture surface features of clinically failed ceramic restorations and with those of controlled laboratory test specimens fabricated from the same materials. Ten fractured Dicor crowns and 12 fractured Cerestore crows were retrieved and analyzed. Optical microscopy of the failed crowns revealed that the critical segments of nine of the 10 (90%) Dicor crowns and nine of the 12 (75%) Cerestore crowns were acceptable for fractographic analysis. Twelve disks of each material were fabricated as controls and fractured by bi-axial flexure for analysis of the similarities and/or differences between the fractographic features of fractured clinical crowns and the disks. Each of the 10 Dicor crowns was observed to fail along the internal surface. For 78% of the Cerestore crowns, failure initiation occurred at the porcelain/core interface or inside the core material. Critical flaw sizes of the failed Dicor crowns ranged from 127 to 272 microns. Failure stresses of the Dicor crowns, estimated by fractographic techniques and fracture mechanics relationships, ranged from 65 to 94 MPa. Estimated failure stresses for two of the Cerestore crowns which had failure initiation sites in the porcelain layer were 15 and 68 MPa. It is concluded that the fracture initiation sites of dental ceramics are controlled primarily by the location and size of the critical flaw, and not by specimen thickness.


Subject(s)
Crowns , Dental Porcelain/chemistry , Aluminum Oxide/chemistry , Chemical Phenomena , Chemistry, Physical , Dental Stress Analysis , Hardness , Humans , Materials Testing , Microscopy, Electron, Scanning , Porosity , Prosthesis Failure , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...