1.
BMC Infect Dis ; 24(1): 646, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38937708

ABSTRACT

INTRODUCTION: When COVID-19 hit the world in 2019, an enhanced focus on diagnostic testing for SARS-CoV-2 was essential for a successful pandemic response. Testing laboratories stretched their capabilities for the new coronavirus by adopting different test methods. The necessity of having external quality assurance (EQA) mechanisms was even more critical due to this rapid expansion. However, there was a lack of experience in providing the necessary SARS-CoV-2 EQA materials, especially in locations with constrained resources. OBJECTIVE: We aimed to create a PT (Proficiency testing) programme based on the Dried Tube Specimens (DTS) method that would be a practical option for molecular based SARS-CoV-2 EQA in Low- and Middle-Income Countries. METHODS: Based on previous ISO/IEC 17043:2010 accreditation experiences and with assistance from the US Centers for Disease Control and Prevention, The Supranational Reference Laboratory of Uganda (adapted the DTS sample preparation method and completed a pilot EQA program between 2020 and 2021. Stability and panel validation testing was conducted on the designed materials before shipping to pilot participants in six African countries. Participants received a panel containing five SARS-CoV-2 DTS samples, transported at ambient conditions. Results submitted by participants were compared to validation results. Participants were graded as satisfactory (≥ 80%) or unsatisfactory (< 80%) and performance reports disseminated. RESULTS: Our SARS-CoV-2 stability experiments showed that SARS-CoV-2 RNA was stable (-15 to -25 °C, 4 to 8 °C, (18 to 28 °C) room temperature and 35 to 38 °C) as well as DTS panels (4 to 8 °C, 18 to 28 °C, 35 to 38 °C and 45 °C) for a period of 4 weeks. The SARS-CoV-2 DTS panels were successfully piloted in 35 test sites from Zambia, Malawi, Mozambique, Nigeria, and Seychelles. The pilot results of the participants showed good accuracy, with an average of 86% (30/35) concordance with the original SARS CoV-2 expectations. CONCLUSION: The SARS-CoV-2 DTS PT panel is reliable, stable at ambient temperature, simple to prepare and requires minimal resources.


Subject(s)
COVID-19 , Developing Countries , Laboratory Proficiency Testing , SARS-CoV-2 , Specimen Handling , Humans , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Specimen Handling/methods , Specimen Handling/standards , COVID-19 Testing/methods , Uganda , Pilot Projects
2.
PLoS One ; 18(3): e0282650, 2023.
Article in English | MEDLINE | ID: mdl-36897841

ABSTRACT

BACKGROUND: Proficiency testing (PT) has been hard to set up due to cost limitations and technical capacity. Conventional Xpert MTB/RIF PT programs use liquid and culture spots which require stringent storage and transportation conditions with cross-contamination chances prevalent. These setbacks prompted the use of dried tube specimens (DTS) for Ultra assay PT. For continuity of PT provision, stability of DTS and compatibility with testing protocols when kept for a long period needs to be established. METHODS: DTS were prepared from known isolates inactivated using a hot air oven at 85°C. 100µl of bacterial suspensions were aliquoted and dried inside a Biosafety cabinet. Panel validation was done to establish the baseline Deoxyribonucleic acid (DNA) concentration in terms of cycle threshold (Ct) value. DTS aliquots were shipped to participants to test and report within six weeks. The remaining DTS were kept at 2-8°C and room temperature for one year with testing at six months. Twenty (20) DTS samples per set remaining at one year were heated at 55°C for two weeks before testing. The means of the different samples were compared to validation data using paired t-tests. Boxplots were designed to visualize the differences in the medians of the DTS. RESULTS: Overall mean Ct value increased by 4.4 from the validation to testing after one year at the different storage conditions. Samples heated at 55°C showed a 6.4 Ct difference from validation data. Testing done at six months on 2-8°C stored items showed no statistical difference. At all the remaining testing times and conditions, P-values were less than 0.008 although the absolute mean Ct when compared showed slight increments and accommodated differences for the detection of MTB and rifampicin resistance. Median values for samples stored at 2-8°C were lower compared to those at room temperature. CONCLUSION: DTS stored at 2-8°C remain more stable for one year compared to higher temperatures and can be consistently used as PT materials in more than one PT round for biannual PT providers.


Subject(s)
Mycobacterium tuberculosis , Resource-Limited Settings , Humans , Uganda , Laboratory Proficiency Testing/methods , Rifampin , Sensitivity and Specificity
3.
PLoS One ; 16(5): e0251691, 2021.
Article in English | MEDLINE | ID: mdl-33989348

ABSTRACT

BACKGROUND: Following the WHO's endorsement of GeneXpert MTB/RIF assay for tuberculosis diagnosis in 2010, Uganda's ministry of health introduced the assay in its laboratory network in 2012. However, assessing the quality of the result produced from this technique is one of its major implementation challenges. To bridge this gap, the National tuberculosis reference laboratory (NTRL) introduced the GeneXpert MTB/RIF proficiency testing (PT) Scheme in 2015. METHODS: A descriptive cross-sectional study on the GeneXpert PT scheme in Uganda was conducted between 2015 and 2018. Sets of panels each comprising four 1ml cryovial liquid samples were sent out to enrolled participants at preset testing periods. The laboratories' testing accuracies were assessed by comparing their reported results to the expected and participants' consensus results. Percentage scores were assigned and feedback reports were sent back to laboratories. Follow up of sites with unsatisfactory results was done through "on and off-site support". Concurrently, standardization of standard operating procedures (SOPs) and practices to the requirements of the International Organization for Standardization (ISO) 17043:2010 was pursued. RESULTS: Participants gradually increased during the program from 56 in the pilot study to 148 in Round 4 (2018). Continual participation of a particular laboratory yielded an odd of 2.5 [95% confidence interval (CI), 1.22 to 4.34] times greater for achieving a score of above 80% with each new round it participated. The "on and off-site" support supervision documented improved performance of failing laboratories. Records of GeneXpert MTB/RIF PT were used to achieve accreditation to ISO 17043:2010 in 2018. CONCLUSION: Continued participation in GeneXpert MTB/RIF PT improves testing accuracy of laboratories. Effective implementation of this scheme requires competent human resources, facility and equipment, functional quality management system, and adherence to ISO 17043:2010.


Subject(s)
Laboratories , Laboratory Proficiency Testing , Mycobacterium tuberculosis/genetics , Tuberculosis/diagnosis , Tuberculosis/genetics , Cross-Sectional Studies , Female , Humans , Male , Pilot Projects , Uganda