Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
1.
Muscle Nerve ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963007

ABSTRACT

INTRODUCTION/AIMS: Conventional F wave analysis involves a relatively uniform physiological environment induced by supramaximal stimulations. The F wave characteristics in a dynamic physiological condition, however, are rarely investigated. This study aimed to improve understanding of F wave properties in the more dynamic process by introducing a novel method to analyze F waves based on the compound muscle action potential (CMAP) scan technique. METHODS: Twenty four healthy subjects participated in the study. The CMAP scan was applied to record muscle responses in the abductor pollicis brevis (APB) and abductor digiti minimi (ADM) muscles, respectively. F wave characteristics including mean F wave amplitude and latency (F-M latency), persistence and activating threshold were quantified. RESULTS: An average of 200 F waves per muscle were obtained from the CMAP scan recording. Weak to moderate correlations between F wave amplitude and stimulating intensity were observed in most of the APB (19 muscles; r = 0.33 ± 0.14, all p < .05) and ADM (23 muscles, r = 0.46 ± 0.16, all p < .05) muscles. Significantly longer mean F latency and lower activating F-threshold were found in the ADM muscles (F-M latency: APB: 25.43 ± 2.39 ms, ADM: 26.15 ± 2.32 ms, p < .05; F-threshold: APB: 7.68 ± 8.96% CMAP, ADM: 2.35 ± 2.42% CMAP, p < .05). DISCUSSION: This study introduces new features of F waves using the CMAP scan technique and identifies differences of F wave characteristics between the hand muscles. The CMAP scan based F waves analysis can be combined with the motor unit number estimation to assess functional alterations in motor neurons in neurological disorders.

2.
Clin Neurophysiol Pract ; 9: 176-200, 2024.
Article in English | MEDLINE | ID: mdl-38807704

ABSTRACT

The compound muscle action potential (CMAP) is among the first recorded waveforms in clinical neurography and one of the most common in clinical use. It is derived from the summated muscle fiber action potentials recorded from a surface electrode overlying the studied muscle following stimulation of the relevant motor nerve fibres innervating the muscle. Surface recorded motor unit potentials (SMUPs) are the fundamental units comprising the CMAP. Because it is considered a basic, if not banal signal, what it represents is often underappreciated. In this review we discuss current concepts in the anatomy and physiology of the CMAP. These have evolved with advances in instrumentation and digitization of signals, affecting its quantitation and measurement. It is important to understand the basic technical and biological factors influencing the CMAP. If these influences are not recognized, then a suboptimal recording may result. The object is to obtain a high quality CMAP recording that is reproducible, whether the study is done for clinical or research purposes. The initial sections cover the relevant CMAP anatomy and physiology, followed by how these principles are applied to CMAP changes in neuromuscular disorders. The concluding section is a brief overview of CMAP research where advances in recording systems and computer-based analysis programs have opened new research applications. One such example is motor unit number estimation (MUNE) that is now being used as a surrogate marker in monitoring chronic neurogenic processes such as motor neuron diseases.

3.
J Hist Neurosci ; 33(3): 298-308, 2024.
Article in English | MEDLINE | ID: mdl-38598175

ABSTRACT

Walter Eichler (1904-1942) performed the first in situ nerve conduction studies in humans. Eichler's work has been largely overlooked and there have been no biographical accounts written of him. His 1937 paper, Über die Ableitung der Aktionspotentiale vom menschlichen Nerven in situ (On the recording of the action potentials from human nerves in situ) was translated and reviewed. Archival material was obtained on his career that was housed predominantly at the University of Freiburg im Breisgau. He had memberships in Nazi organizations but did not appear to be politically active. During his brief career, he constructed novel equipment and established seminal principles for performing nerve conductions on humans. The authors repeated his experiment in the ulnar nerve, which duplicated Eichler's findings. His recordings were quite remarkable given advances in technology. In summary, the Eichler paper is the first study in the development of in situ clinical electroneurography in humans. Many of his procedural observations are still fundamental in the current practice of electroneurography. As best can be determined, his study in humans did not appear ethically compromised. Although Eichler's personal background remains open to question, his paper is a seminal study in the history and development of clinical electroneurography.Abbreviations: AP: Action potential; C: Capacitor; CNP: Compound nerve potential; DC: Direct current; E1: Preferred term for active electrode; E2: Preferred term for reference electrode; NSDÄB: Nationalsozialistische Deutsche NSD-Ärtzebund (National Socialist German Doctors' League; NSDAP: Nationalsozialistische Deutsche Arbeiterpartei (National Socialist German Workers' Party/ Nazi Party); SS: Schutzstaffel (Protective Echelon or Squad of the Nazi party).


Subject(s)
Neural Conduction , Humans , History, 20th Century , Neural Conduction/physiology , Action Potentials/physiology , Ulnar Nerve/physiology , Germany , Electrophysiology/history , Neurophysiology/history , Nerve Conduction Studies
4.
Clin Neurophysiol ; 162: 91-120, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38603949

ABSTRACT

This chapter discusses comprehensive neurophysiological biomarkers utilised in motor neuron disease (MND) and, in particular, its commonest form, amyotrophic lateral sclerosis (ALS). These encompass the conventional techniques including nerve conduction studies (NCS), needle and high-density surface electromyography (EMG) and H-reflex studies as well as novel techniques. In the last two decades, new methods of assessing the loss of motor units in a muscle have been developed, that are more convenient than earlier methods of motor unit number estimation (MUNE),and may use either electrical stimulation (e.g. MScanFit MUNE) or voluntary activation (MUNIX). Electrical impedance myography (EIM) is another novel approach for the evaluation that relies upon the application and measurement of high-frequency, low-intensity electrical current. Nerve excitability techniques (NET) also provide insights into the function of an axon and reflect the changes in resting membrane potential, ion channel dysfunction and the structural integrity of the axon and myelin sheath. Furthermore, imaging ultrasound techniques as well as magnetic resonance imaging are capable of detecting the constituents of morphological changes in the nerve and muscle. The chapter provides a critical description of the ability of each technique to provide neurophysiological insight into the complex pathophysiology of MND/ALS. However, it is important to recognise the strengths and limitations of each approach in order to clarify utility. These neurophysiological biomarkers have demonstrated reliability, specificity and provide additional information to validate and assess lower motor neuron dysfunction. Their use has expanded the knowledge about MND/ALS and enhanced our understanding of the relationship between motor units, axons, reflexes and other neural circuits in relation to clinical features of patients with MND/ALS at different stages of the disease. Taken together, the ultimate goal is to aid early diagnosis, distinguish potential disease mimics, monitor and stage disease progression, quantify response to treatment and develop potential therapeutic interventions.


Subject(s)
Amyotrophic Lateral Sclerosis , Biomarkers , Electromyography , Motor Neuron Disease , Motor Neurons , Neural Conduction , Humans , Amyotrophic Lateral Sclerosis/physiopathology , Amyotrophic Lateral Sclerosis/diagnostic imaging , Motor Neurons/physiology , Motor Neuron Disease/physiopathology , Motor Neuron Disease/diagnostic imaging , Motor Neuron Disease/diagnosis , Electromyography/methods , Neural Conduction/physiology
5.
Muscle Nerve ; 68(5): 767-770, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37632347

ABSTRACT

INTRODUCTION/AIMS: To date, there is minimal literature in following resolution of partial conduction block (PCB) in compression neuropathy. We investigated a case of cyclist's palsy with PCB from compression using serial nerve conduction studies to monitor recovery. METHODS: Clinical recovery was monitored concomitant with compound muscle action potential (CMAP) amplitudes that were recorded from 3 ulnar-innervated muscles (first dorsal interosseous [FDI] 6 days post-onset, palmar interosseus [PI] 16 days post-onset, and abductor digiti minimi [ADM]) in both limbs. Sensory nerve conduction studies and needle electromyography were also performed. RESULTS: PCB was demonstrated in the FDI and PI with recordings done proximal and distal to the site of injury. Recovery in the FDI and PI occurred between week 2 and 3 post-onset but continued to improve until about 14 wk post-onset when the CMAP values on the affected side approximated the contralateral side. Sensory conduction studies were normal and symmetric. Needle EMG at 21 days post-injury showed no active denervation and a reduced number of normal-appearing motor unit potentials firing >16 Hz that reverted to a normal pattern on final study at 99 days post-onset. DISCUSSION: This study shows how rapidly PCB may initially resolve although full recovery takes longer. Criteria for defining PCB may be misleading when doing nerve conductions and comparing only the evoked responses below and above the block. To fully characterize PCB, it is important to optimize the position of the active recording electrode (E1) as well as compare results with the unaffected side.

6.
Muscle Nerve ; 68(2): 210-214, 2023 08.
Article in English | MEDLINE | ID: mdl-37300406

ABSTRACT

INTRODUCTION/AIMS: Switching between different types of electrodes during motor and sensory nerve conduction studies adds time to a study. We investigated the use of disposable disc electrodes (DDE) used for motor nerve conduction studies to record the antidromic sensory nerve action potential (SNAP) in median, ulnar and radial sensory nerve conduction studies. METHODS: The SNAP was recorded using four different electrode types: reusable ring, reusable bar, disposable ring, and DDE in a random rotating order. Studies were performed in healthy subjects. Other than being an adult with no history of neuromuscular disease, there were no exclusion criteria. RESULTS: We studied 20 subjects (11 females, 9 males; age 41.1 ± 15.7 y). The SNAP waveforms recorded by all four electrode types were similar. There was no statistically significant difference in the onset latency, peak latency (PL), negative peak amplitude (NPA), peak to peak amplitude, or conduction velocity. In individual nerve recordings, the absolute PL difference between reusable ring electrodes (our current standard) and DDE was less than 0.2 ms in 58 of 60 (97%) nerves. The mean absolute NPA difference was 3.1 µV (standard deviation = 2.85 µV). Recordings with NPA difference >5 µV also had high NPA and/or had large artifacts. DISCUSSION: DDE may be used for performing motor and sensory nerve conduction studies. This can reduce the time required for electrodiagnostic testing.


Subject(s)
Evoked Potentials , Neural Conduction , Adult , Female , Humans , Male , Middle Aged , Action Potentials/physiology , Electrodes , Evoked Potentials/physiology , Median Nerve , Neural Conduction/physiology , Reaction Time/physiology , Ulnar Nerve/physiology
7.
Muscle Nerve ; 67(6): 439-455, 2023 06.
Article in English | MEDLINE | ID: mdl-36815566

ABSTRACT

The extracellular waveform manifestations of the intracellular action potential are the quintessential diagnostic foundation of electrodiagnostic medicine, and clinical neurophysiology in general. Volume conduction is the extracellular current flow and associated voltage distributions in an ionic conducting media, such as occurs in the human body. Both surface and intramuscular electrodes, in association with contemporary digital electromyographic systems, permit very sensitive detection and visualization of this extracellular spontaneous, voluntary, and evoked nerve/muscle electrical activity. Waveform configuration, with its associated discharge rate/rhythm, permits the identification of normal and abnormal waveforms, thereby assisting in the diagnosis of nerve and muscle pathology. This monograph utilizes a simple model to explain the various waveforms that may be encountered. There are a limited number of waveforms capable of being generated in excitable tissues which conform to well-known volume conductor concepts. Using these principles, such waveforms can be quickly identified in real time during clinical studies.


Subject(s)
Muscles , Humans , Action Potentials/physiology , Muscles/innervation
8.
Muscle Nerve ; 67(4): 310-314, 2023 04.
Article in English | MEDLINE | ID: mdl-36605021

ABSTRACT

INTRODUCTION/AIMS: Low-amplitude compound muscle action potential (CMAP) suggests a neuromuscular pathology. Low amplitude will also result from a defective E1 electrode or its lead, that is, a technical artifact. The aim of this study was to investigate the effect of a defective E2 electrode lead on the CMAP. METHODS: The CMAP was recorded using standard nerve conduction methodology and all electrode leads connected properly. Signals were then recorded when either the E1 or the E2 electrode lead was disconnected from the amplifier. This simulated a defective electrode lead. Studies were performed in four nerves of a healthy subject. RESULTS: CMAP amplitude was reduced as expected when E1 was disconnected. Surprisingly, the amplitude fell by more than 65% when the E2 lead was disconnected, although E1 was properly connected. DISCUSSION: E1 and E2 electrodes contribute to the CMAP. A defective recording electrode lead to E1 or E2 results in a low-amplitude CMAP. The amplitude drop observed with a disconnected E2 lead was far greater than the signal recorded by the E2 electrode. This occurs due to the amplifier's inherent property to reduce the voltage difference between the E1 and E2 inputs. When E2 lead is defective, the CMAP will be an attenuated version of the signal recorded by the E1 electrode, and vice versa. When low-amplitude CMAP amplitude is observed in all conduction studies, technical artifact should be considered before exploring the pathological basis for the abnormal results.


Subject(s)
Muscles , Neural Conduction , Humans , Action Potentials/physiology , Neural Conduction/physiology , Electrodes , Healthy Volunteers , Muscle, Skeletal/physiology , Electromyography/methods
9.
Muscle Nerve ; 66(6): 750-756, 2022 12.
Article in English | MEDLINE | ID: mdl-36214178

ABSTRACT

INTRODUCTION/AIMS: A prevailing concept of motor unit (MU) recruitment used for calculating recruitment ratio (RR) suggests a progressive linear increase in firing rate (FR). The objective of this study is to assess its validity. METHODS: Concentric needle electromyography (EMG) recordings were made in normal muscle and abnormal muscle of patients with neurogenic findings. Signals recorded at low force were visually decomposed to study MU FR at onset, recruitment of a second MU, and recruitment of more MUs with further increases in force. RESULTS: We observed one to six MUs discharging at a rate < 15 Hz in normal muscles at low force. The MU FR was 5-8 Hz at onset. With increasing force, FR increased by 3-5 Hz and then idled at <15 Hz while other MUs were recruited. The recruitment frequency (RF) and RR had low sensitivity and were abnormal mainly in moderately to severely weak muscles. DISCUSSION: Our data are consistent with FR analysis results described by other investigators. It does not support a progressive linear increase in MU FR with recruitment. A revised model for MU recruitment at low effort during gradual increase in force is presented. On subjective assessment, the FR of the fastest firing MU can help detect MU loss in neurogenic processes.


Subject(s)
Muscle Contraction , Recruitment, Neurophysiological , Humans , Recruitment, Neurophysiological/physiology , Muscle Contraction/physiology , Motor Neurons/physiology , Electromyography , Muscles , Isometric Contraction , Muscle, Skeletal/physiology
10.
Clin Neurophysiol ; 139: 119-127, 2022 07.
Article in English | MEDLINE | ID: mdl-35537985

ABSTRACT

OBJECTIVE: The compound muscle action potential (CMAP) scan is useful to study motor unit (MU) loss. It is of interest to develop simple measurements of the scan. METHODS: CMAP scan recordings were performed in the abductor pollicis brevis muscle of 20 control subjects and 26 patients with amyotrophic lateral sclerosis (ALS). They were analyzed using two new measurements called Step index (STEPIX) reflecting the number of steps, and Amplitude index (AMPIX) for amplitude of these steps. RESULTS: In control subjects, STEPIX ranged from 71 to 172 while AMPIX was 78-158 µV. In ALS patients STEPIX was reduced and AMPIX was increased. The degree of change in STEPIX and AMPIX varied among patients reflecting the success or failure of reinnervation. Follow up studies in 9 muscles demonstrated reduced STEPIX and increased AMPIX despite minimal change in the CMAP. CONCLUSIONS: STEPIX and AMPIX are deterministic measurements of the CMAP scan made using a spreadsheet program. STEPIX and AMPIX can be inferred as indices for the number of motor units and their size, and demonstrate the expected pattern in ALS patients. SIGNIFICANCE: The new algorithm for CMAP scan analysis may be useful to study disease progression in patients with ALS.


Subject(s)
Amyotrophic Lateral Sclerosis , Action Potentials/physiology , Algorithms , Amyotrophic Lateral Sclerosis/diagnostic imaging , Disease Progression , Humans , Muscle, Skeletal/diagnostic imaging
11.
Clin Neurophysiol ; 134: 37-42, 2022 02.
Article in English | MEDLINE | ID: mdl-34971939

ABSTRACT

OBJECTIVE: We describe a mathematical model to calculate a single muscle fiber action potential (AP). Based on a marching band pattern, it is an enhancement to our previously described "modified line source" model. METHODS: Calculations were performed using an Excel spread sheet. AP was simulated for a 200 mm long muscle fiber with 60 µm diameter, propagation velocity of 4 m/s, and end-plate located at the center. Several different electrode locations were used to calculate the AP. RESULTS: The AP amplitude was highest at the end-plate where the waveform was biphasic with initial negativity. When the electrode was moved towards the tendon, the amplitude decreased for the first 1.5 mm. The AP was triphasic and its waveform was relatively constant at electrode positions beyond 1.5 mm from the end-plate. It matched the calculations using the modified line source model. When the electrode was near the tendon, the AP amplitude decreased asymmetrically and waveform became biphasic resembling a positive sharp wave. DISCUSSION: The model is conceptually and computationally simple. It simulated the expected AP shape at different electrode positions along the muscle fiber. The waveforms are similar to those obtained from mathematically complex volume conductor models. SIGNIFICANCE: The revised model can be useful for teaching and future simulation studies.


Subject(s)
Action Potentials/physiology , Computer Simulation , Models, Neurological , Muscle Fibers, Skeletal/physiology , Humans
12.
Muscle Nerve ; 65(2): 203-210, 2022 02.
Article in English | MEDLINE | ID: mdl-34687220

ABSTRACT

INTRODUCTION/AIMS: The motor unit size index (MUSIX) may provide insight into reinnervation patterns in diseases such as amyotrophic lateral sclerosis (ALS). However, it is not known whether MUSIX detects clinically relevant changes in reinnervation, or if all muscles manifest changes in MUSIX in response to reinnervation after motor unit loss. METHODS: Fifty-seven patients with ALS were assessed at 3-month intervals for 12 months in four centers. Muscles examined were abductor pollicis brevis, abductor digiti minimi, biceps brachii, and tibialis anterior. Results were split into two groups: muscles with increases in MUSIX and those without increases. Longitudinal changes in MUSIX, motor unit number index (MUNIX), compound muscle action potential amplitude, and Medical Research Council strength score were investigated. RESULTS: One hundred thirty-three muscles were examined. Fifty-nine percent of the muscles exhibited an increase in MUSIX during the study. Muscles with MUSIX increases lost more motor units (58% decline in MUNIX at 12 months, P < .001) than muscles that did not increase MUSIX (34.6% decline in MUNIX at 12 months, P < .001). However, longitudinal changes in muscle strength were similar. When motor unit loss was similar, the absence of a MUSIX increase was associated with a significantly greater loss of muscle strength (P = .002). DISCUSSION: MUSIX increases are associated with greater motor unit loss but relative preservation of muscle strength. Thus, MUSIX appears to be measuring a clinically relevant response that can provide a quantitative outcome measure of reinnervation in clinical trials. Furthermore, MUSIX suggests that reinnervation may play a major role in determining the progression of weakness.


Subject(s)
Amyotrophic Lateral Sclerosis , Electromyography/methods , Humans , Motor Neurons/physiology , Muscle Strength , Muscle, Skeletal/physiology
13.
Muscle Nerve ; 64(1): 86-89, 2021 07.
Article in English | MEDLINE | ID: mdl-33822375

ABSTRACT

INTRODUCTION/AIMS: The virtual cathode (VC) is a site near the anode where the nerve can be stimulated. Costimulation of neighboring nerves via the VC can affect recording and interpretation of responses. Hence, it is important to teach trainees the concept of the VC. The VC has been demonstrated previously with subtle changes in response latency, amplitude, and shape. Herein we describe an experiment that simply demonstrates a VC with its effects recognizable by gross changes in waveforms. METHODS: Compound muscle action potentials of the abductor pollicis brevis were recorded using various placements of the cathode and anode at different stimulus intensity levels. Studies were performed in nine healthy subjects. RESULTS: Three patterns were observed that demonstrated no stimulation, partial stimulation, and complete nerve stimulation by the VC. Partial stimulation yielded responses with long duration and low amplitude. Response patterns also depended on stimulus strength and proximity of the nerve from the skin surface. DISCUSSION: This experiment demonstrates that nerve stimulation can occur near the anode when high-intensity stimulus is used. It also illustrates collision of action potentials. This exercise can help trainees understand potential pitfalls in nerve conduction studies, especially at very proximal stimulation sites or when high stimulus intensity is used.


Subject(s)
Clinical Competence , Electric Stimulation Therapy/instrumentation , Electric Stimulation Therapy/methods , Median Nerve/physiology , Neural Conduction/physiology , Action Potentials/physiology , Adult , Aged , Electrodes , Electromyography/instrumentation , Electromyography/methods , Female , Humans , Male , Middle Aged , Muscle, Skeletal/innervation , Muscle, Skeletal/physiology , Neurologic Examination/instrumentation , Neurologic Examination/methods
14.
Muscle Nerve ; 64(1): 99-103, 2021 07.
Article in English | MEDLINE | ID: mdl-33899969

ABSTRACT

INTRODUCTION/AIMS: Our electrodiagnostic laboratory uses reference limits (RL) that have been handed down for four decades. With changes in instrumentation and technique, we wish to know if our RL should be modified. It is also useful to have RL based on patient demographics. METHODS: Latency and velocity data from motor nerve conduction studies of 740 adult patients studied over an 8 mo period were tabulated. RL were derived using both extrapolated reference value (ERef) and multi-variable extrapolated reference value (MeRef) methods. RESULTS: Distal latency values showed a significant but weak correlation with age and/or height. ERef limits for the median and ulnar nerve latency (3.96 and 3.45 ms, respectively) were very similar to current laboratory limits (3.9 and 3.3 ms, respectively). ERef limits for the tibial and fibular nerve latency (5.1 and 4.95 ms, respectively) were slightly shorter. Ulnar velocity did not depend on age or height. The ERef limit was the same as our present laboratory limit (50 m/s). Median and tibial velocity limits decreased with age (R2  > 0.25). Fibular motor nerve conduction limits decreased with age and height (R2  = 0.39). DISCUSSION: ERef and MeRef were useful to validate and revise our latency and velocity RL. We will use ERef limits for tibial and fibular latency. MeRef generated linear regression equations based on age and/or height will be used for conduction velocity analysis of median, fibular, and tibial nerves. This will increase the specificity of our values.


Subject(s)
Median Nerve/physiology , Neural Conduction/physiology , Peroneal Nerve/physiology , Tibial Nerve/physiology , Ulnar Nerve/physiology , Adult , Female , Humans , Male , Middle Aged , Reference Values , Retrospective Studies
15.
Muscle Nerve ; 63(5): 657-660, 2021 05.
Article in English | MEDLINE | ID: mdl-33565086

ABSTRACT

No consensus criteria exist for recording and analyzing waveforms in clinical electromyography (EMG). There have been significant technical improvements in recent decades that are under-used in both routine practice and research. In current practice, disciplined techniques in acquisition and analysis of signals are required to appropriately define them. As an example, we describe such an exercise in acquisition and analysis. During a routine study, atypical spontaneous activity was encountered. High-quality digital recordings were stored for off-line analysis. These revealed waveforms that could be isolated and quantitatively defined using basic instrumentation available on most modern EMG systems: "slow" firing fibrillation potentials and a repeating fasciculation potential. Subjective analysis alone could not have identified them. To improve accuracy in identification and understanding of these waveforms, we propose criteria for data collection and signal analysis. This is critical for quality in routine practice, education, and proper reporting of electrophysiological signals.


Subject(s)
Electromyography/methods , Fasciculation/diagnosis , Muscle, Skeletal/physiopathology , Action Potentials/physiology , Fasciculation/physiopathology , Humans , Signal Processing, Computer-Assisted
16.
Muscle Nerve ; 63(5): 737-744, 2021 05.
Article in English | MEDLINE | ID: mdl-33576529

ABSTRACT

INTRODUCTION: In this study we describe a method called "multivariable extrapolated reference values" (MeRef) that derives reference values (RVs) using patient data and includes the dependence of these variables on multiple patient demographic variables, such as age and height. METHODS: Computer simulations were used to generate "normal" and "patient" nerve conduction data. Median, ulnar, and tibial motor nerve conduction data from 500 patients studied were tabulated. Data were analyzed using the MeRef method. RESULTS: The simulations showed great similarity between RVs obtained from MeRef of "patient" data and traditional analysis of "normal" data. In the real patient data, MeRef gave RVs as regression equations based on patient age and/or height. DISCUSSION: MeRef can provide RVs by including patient demographic data and does not require subject grouping. It provides parameters of multivariable linear regression and standard deviation, and requires a few hundred patient studies to define reference values.


Subject(s)
Median Nerve/physiology , Motor Neurons/physiology , Neural Conduction/physiology , Tibial Nerve/physiology , Ulnar Nerve/physiology , Adult , Age Factors , Aged , Computer Simulation , Female , Humans , Male , Middle Aged , Neurologic Examination , Reference Values
17.
Muscle Nerve ; 63(4): 525-530, 2021 04.
Article in English | MEDLINE | ID: mdl-33382480

ABSTRACT

BACKGROUND: Despite use of qualitative laryngeal electromyography (LEMG) guided botulinum toxin A (BoNT-A) injection for treatment of adductor spasmodic dysphonia (AdSD), unsatisfactory injections and complete "misses" remain problematic. We aimed to determine if the quantitative LEMG measure of number of small segments (NSS) correlates with voice outcomes following (BoNT-A injection for AdSD. METHODS: Automated quantitative LEMG analysis was performed during electromyography (EMG) -guided BoNT-A injection into the thyroarytenoid-lateral cricoarytenoid muscle complex for treatment of AdSD. Pre-injection phonatory NSS values were correlated with clinical voice outcomes and patient reported injection results. RESULTS: Quantitative LEMG measures were obtained for 45 AdSD patients (28 female, mean age 60.8 ± 12.8 years) during EMG-guided BoNT-A injection. Mean sampled NSS during phonation immediately prior to BoNT-A injection was 524 ± 323 (range: 2-904). Mean follow up was 36.5 ± 9.4 days; one patient was lost to follow-up. In comparison to their previous BoNT-A injection, the current injection was rated as worse, same, and better by 13 (29.5%), 25 (56.8%), and 6 (13.6%) patients, respectively. All 4 (9.1%) patients with NSS < 200 rated their BoNT-A injection result as worse than previous, and change in Voice Handicap Index-10 (VHI-10) scores were worse or without change. CONCLUSIONS: Aiming for an NSS value greater than 200 during phonation prior to BoNT-A toxin injection for AdSD may reduce unfavorable voice outcomes.


Subject(s)
Botulinum Toxins, Type A/pharmacology , Dysphonia/drug therapy , Dysphonia/physiopathology , Electromyography , Laryngeal Muscles/physiopathology , Aged , Aged, 80 and over , Dysphonia/diagnosis , Electromyography/methods , Female , Humans , Injections, Intramuscular/methods , Laryngeal Muscles/drug effects , Male , Middle Aged , Retrospective Studies , Treatment Outcome
18.
Muscle Nerve ; 63(1): 113-116, 2021 01.
Article in English | MEDLINE | ID: mdl-33063851

ABSTRACT

BACKGROUND: The extrapolated reference values procedure (E-Ref) was used to compare data from a single institution with the recently published reference value (RV) for concentric electrode jitter. METHODS: Data from voluntarily activated concentric needle jitter studies in the frontalis muscle were obtained using retrospective chart review. All measured signals were reviewed for acceptable quality. Cutoff values for increased jitter were calculated using E-Ref, and compared with the published RVs. RESULTS: At total of 1501 apparent single-fiber action potential (ASFAP) pairs were reviewed; 1371 ASFAP pairs were determined to have acceptable quality. The cutoff value identified by E-Ref from all reviewed ASFAP pairs was 36 microseconds and the cutoff for acceptable pairs was 35 microseconds. Using either of these cutoff values (36 or 35 microseconds) did not result in a significant difference in percentage of jitter recordings considered normal when compared with the recently published RV (38 microseconds). DISCUSSION: The single-institution jitter cutoff value obtained by E-Ref gives results that are not significantly different from the reported RV.


Subject(s)
Muscle Contraction/physiology , Muscle Fibers, Skeletal/physiology , Muscle, Skeletal/physiology , Neuromuscular Junction/physiology , Action Potentials/physiology , Adult , Electrodes , Electromyography/methods , Female , Humans , Male , Middle Aged , Reference Values , Retrospective Studies
19.
Muscle Nerve ; 62(2): 233-238, 2020 08.
Article in English | MEDLINE | ID: mdl-32415859

ABSTRACT

INTRODUCTION: In contrast to needle electromyography (EMG), surface EMG recordings are painless. It is of interest to develop methods to analyze surface EMG for diagnostic purposes. METHODS: Surface EMG interference pattern (SIP) recordings from the abductor pollicis brevis muscle of healthy subjects and subjects with amyotrophic lateral sclerosis (ALS) were analyzed by measuring root-mean-square (RMS) voltage, mean rectified voltage, form factor (FF), and the clustering index (CI). The FF vs SIP area plot was used for analysis. RESULTS: The SIP FF was increased and abnormal in ALS subjects, especially when SIP area was less than 200 mVms. Power regression showed a faster FF decline with SIP area in ALS patients than in healthy subjects. The CI and FF showed a strong correlation. DISCUSSION: FF is easy to calculate and demonstrates abnormalities in ALS patients.


Subject(s)
Action Potentials/physiology , Amyotrophic Lateral Sclerosis/physiopathology , Electromyography/methods , Muscle Contraction/physiology , Muscle, Skeletal/physiopathology , Adult , Aged , Aged, 80 and over , Case-Control Studies , Electrodiagnosis/methods , Female , Hand/physiopathology , Humans , Male , Middle Aged
20.
Clin Neurophysiol ; 131(1): 243-258, 2020 01.
Article in English | MEDLINE | ID: mdl-31761717

ABSTRACT

Standardization of Electromyography (EMG) instrumentation is of particular importance to ensure high quality recordings. This consensus report on "Standards of Instrumentation of EMG" is an update and extension of the earlier IFCN Guidelines published in 1999. First, a panel of experts in different fields from different geographical distributions was invited to submit a section on their particular interest and expertise. Then, the merged document was circulated for comments and edits until a consensus emerged. The first sections in this document cover technical aspects such as instrumentation, EMG hardware and software including amplifiers and filters, digital signal analysis and instrumentation settings. Other sections cover the topics such as temporary storage, trigger and delay line, averaging, electrode types, stimulation techniques for optimal and standardised EMG examinations, and the artefacts electromyographers may face and safety rules they should follow. Finally, storage of data and databases, report generators and external communication are summarized.


Subject(s)
Amplifiers, Electronic , Computers , Consensus , Electrodes , Electromyography/instrumentation , Software , Action Potentials , Artifacts , Communication , Databases as Topic , Electric Stimulation/instrumentation , Electroencephalography , Electromyography/methods , Electromyography/standards , Equipment Design , Ergonomics/methods , Evoked Potentials, Somatosensory/physiology , Filtration/instrumentation , Humans , Needles , Neural Conduction , Safety , Sensory Receptor Cells/physiology , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...