Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Nanotechnology ; 32(4): 045502, 2021 Jan 22.
Article in English | MEDLINE | ID: mdl-33049728

ABSTRACT

The discovery of the field effect in graphene initiated the development of graphene field effect transistor (FET) sensors, wherein high mobility surface conduction is readily modulated by surface adsorption. For all graphene transistor sensors, low-frequency 1/f noise determines sensor resolution, and the absolute measure of 1/f noise is thus a crucial performance metric for sensor applications. Here we report a simple method for reducing 1/f noise by scaling the active area of graphene FET sensors. We measured 1/f noise in graphene FETs with size 5 µm × 5 µm to 5.12 mm × 5.12 mm, observing more than five orders of magnitude reduction in 1/f noise. We report the lowest normalized graphene 1/f noise parameter observed to date, 5 × 10-13, and we demonstrate a sulfate ion sensor with a record resolution of 1.2 × 10-3 log molar concentration units. Our work highlights the importance of area scaling in graphene FET sensor design, wherein increased channel area improves sensor resolution.

2.
Nat Commun ; 11(1): 3226, 2020 06 26.
Article in English | MEDLINE | ID: mdl-32591504

ABSTRACT

Real-time, high resolution, simultaneous measurement of multiple ionic species is challenging with existing chromatographic, spectrophotometric and potentiometric techniques. Potentiometric ion sensors exhibit limitations in both resolution and selectivity. Herein, we develop wafer scale graphene transistor technology for overcoming these limitations. Large area graphene is an ideal material for high resolution ion sensitive field effect transistors (ISFETs), while simultaneously enabling facile fabrication as compared to conventional semiconductors. We develop the ISFETs into an array and apply Nikolskii-Eisenman analysis to account for cross-sensitivity and thereby achieve high selectivity. We experimentally demonstrate real-time, simultaneous concentration measurement of K+, Na+, [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text] and Cl- with a resolution of [Formula: see text] concentration units. The array achieves an accuracy of  ±0.05 log concentration. Finally, we demonstrate real-time ion concentration measurement in an aquarium with lemnoideae lemna over three weeks, where mineral uptake by aquatic organisms can be observed during their growth.


Subject(s)
Graphite/chemistry , Ion-Selective Electrodes , Transistors, Electronic , Anions , Cations , Electrolytes/chemistry , Hydrogen-Ion Concentration , Optical Imaging , Temperature , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...