Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 249
Filter
1.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38703375

ABSTRACT

AIMS: Ablation of monomorphic ventricular tachycardia (MMVT) has been shown to reduce shock frequency and improve survival. We aimed to compare cause-specific risk factors for MMVT and polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) and to develop predictive models. METHODS AND RESULTS: The multicentre retrospective cohort study included 2668 patients (age 63.1 ± 13.0 years; 23% female; 78% white; 43% non-ischaemic cardiomyopathy; left ventricular ejection fraction 28.2 ± 11.1%). Cox models were adjusted for demographic characteristics, heart failure severity and treatment, device programming, and electrocardiogram metrics. Global electrical heterogeneity was measured by spatial QRS-T angle (QRSTa), spatial ventricular gradient elevation (SVGel), azimuth, magnitude (SVGmag), and sum absolute QRST integral (SAIQRST). We compared the out-of-sample performance of the lasso and elastic net for Cox proportional hazards and the Fine-Gray competing risk model. During a median follow-up of 4 years, 359 patients experienced their first sustained MMVT with appropriate implantable cardioverter-defibrillator (ICD) therapy, and 129 patients had their first PVT/VF with appropriate ICD shock. The risk of MMVT was associated with wider QRSTa [hazard ratio (HR) 1.16; 95% confidence interval (CI) 1.01-1.34], larger SVGel (HR 1.17; 95% CI 1.05-1.30), and smaller SVGmag (HR 0.74; 95% CI 0.63-0.86) and SAIQRST (HR 0.84; 95% CI 0.71-0.99). The best-performing 3-year competing risk Fine-Gray model for MMVT [time-dependent area under the receiver operating characteristic curve (ROC(t)AUC) 0.728; 95% CI 0.668-0.788] identified high-risk (> 50%) patients with 75% sensitivity and 65% specificity, and PVT/VF prediction model had ROC(t)AUC 0.915 (95% CI 0.868-0.962), both satisfactory calibration. CONCLUSION: We developed and validated models to predict the competing risks of MMVT or PVT/VF that could inform procedural planning and future randomized controlled trials of prophylactic ventricular tachycardia ablation. CLINICAL TRIAL REGISTRATION: URL:www.clinicaltrials.gov Unique identifier:NCT03210883.


Subject(s)
Defibrillators, Implantable , Primary Prevention , Tachycardia, Ventricular , Ventricular Fibrillation , Humans , Female , Male , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/prevention & control , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Middle Aged , Retrospective Studies , Primary Prevention/methods , Risk Factors , Risk Assessment , Aged , Ventricular Fibrillation/prevention & control , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/physiopathology , Ventricular Fibrillation/therapy , Treatment Outcome , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Electrocardiography , Catheter Ablation , Time Factors , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology
2.
Circ Genom Precis Med ; 17(3): e000095, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38779844

ABSTRACT

Wearable devices are increasingly used by a growing portion of the population to track health and illnesses. The data emerging from these devices can potentially transform health care. This requires an interoperability framework that enables the deployment of platforms, sensors, devices, and software applications within diverse health systems, aiming to facilitate innovation in preventing and treating cardiovascular disease. However, the current data ecosystem includes several noninteroperable systems that inhibit such objectives. The design of clinically meaningful systems for accessing and incorporating these data into clinical workflows requires strategies to ensure the quality of data and clinical content and patient and caregiver accessibility. This scientific statement aims to address the best practices, gaps, and challenges pertaining to data interoperability in this area, with considerations for (1) data integration and the scope of measures, (2) application of these data into clinical approaches/strategies, and (3) regulatory/ethical/legal issues.


Subject(s)
American Heart Association , Cardiovascular Diseases , Monitoring, Ambulatory , Humans , Cardiovascular Diseases/therapy , Cardiovascular Diseases/diagnosis , United States , Monitoring, Ambulatory/methods , Monitoring, Ambulatory/standards , Wearable Electronic Devices , Health Information Interoperability
3.
bioRxiv ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38798676

ABSTRACT

In patients with dyssynchronous heart failure (DHF), cardiac conduction abnormalities cause the regional distribution of myocardial work to be non-homogeneous. Cardiac resynchronization therapy (CRT) using an implantable, programmed biventricular pacemaker/defibrillator, can improve the synchrony of contraction between the right and left ventricles in DHF, resulting in reduced morbidity and mortality and increased quality of life. Since regional work depends on wall stress, which cannot be measured in patients, we used computational methods to investigate regional work distributions and their changes after CRT. We used three-dimensional multi-scale patient-specific computational models parameterized by anatomic, functional, hemodynamic, and electrophysiological measurements in eight patients with heart failure and left bundle branch block (LBBB) who received CRT. To increase clinical translatability, we also explored whether streamlined computational methods provide accurate estimates of regional myocardial work. We found that CRT increased global myocardial work efficiency with significant improvements in non-responders. Reverse ventricular remodeling after CRT was greatest in patients with the highest heterogeneity of regional work at baseline, however the efficacy of CRT was not related to the decrease in overall work heterogeneity or to the reduction in late-activated regions of high myocardial work. Rather, decreases in early-activated regions of myocardium performing negative myocardial work following CRT best explained patient variations in reverse remodeling. These findings were also observed when regional myocardial work was estimated using ventricular pressure as a surrogate for myocardial stress and changes in endocardial surface area as a surrogate for strain. These new findings suggest that CRT promotes reverse ventricular remodeling in human dyssynchronous heart failure by increasing regional myocardial work in early-activated regions of the ventricles, where dyssynchrony is specifically associated with hypoperfusion, late systolic stretch, and altered metabolic activity and that measurement of these changes can be performed using streamlined approaches.

5.
Article in English | MEDLINE | ID: mdl-38703164

ABSTRACT

BACKGROUND: In patients with persistent atrial fibrillation (PerAF), antiarrhythmic drugs (AADs) are considered a first-line rhythm-control strategy, whereas catheter ablation is a reasonable alternative. OBJECTIVES: This study sought to examine the prevalence, patient characteristics, and clinical outcomes of patients with PerAF who underwent catheter ablation as a first or second-line strategy. METHODS: This multicenter observational study included consecutive patients with PerAF who underwent first-time ablation between January 2020 and September 2021 in 9 medical centers in the United States. Patients were divided into those who underwent ablation as first-line therapy and those who had ablation as second-line therapy. Patient characteristics and clinical outcomes were compared between the groups. RESULTS: A total of 2,083 patients underwent first-time ablation for PerAF. Of these, 1,086 (52%) underwent ablation as a first-line rhythm-control treatment. Compared with patients treated with AADs as first-line therapy, these patients were predominantly male (72.6% vs 68.1%; P = 0.03), with a lower frequency of hypertension (64.0% vs 73.4%; P < 0.001) and heart failure (19.1% vs 30.5%; P < 0.001). During a mean follow-up of 325.9 ± 81.6 days, arrhythmia-free survival was similar between the groups (HR: 1.13; 95% CI: 0.92-1.41); however, patients in the second-line ablation strategy were more likely to continue receiving AAD therapy (41.5% vs 15.9%; P < 0.001). CONCLUSIONS: A first-line ablation strategy for PerAF is prevalent in the United States, particularly in men with fewer comorbidities. More data are needed to identify patients with PerAF who derive benefit from an early intervention strategy.

8.
Circulation ; 149(14): e1028-e1050, 2024 04 02.
Article in English | MEDLINE | ID: mdl-38415358

ABSTRACT

A major focus of academia, industry, and global governmental agencies is to develop and apply artificial intelligence and other advanced analytical tools to transform health care delivery. The American Heart Association supports the creation of tools and services that would further the science and practice of precision medicine by enabling more precise approaches to cardiovascular and stroke research, prevention, and care of individuals and populations. Nevertheless, several challenges exist, and few artificial intelligence tools have been shown to improve cardiovascular and stroke care sufficiently to be widely adopted. This scientific statement outlines the current state of the art on the use of artificial intelligence algorithms and data science in the diagnosis, classification, and treatment of cardiovascular disease. It also sets out to advance this mission, focusing on how digital tools and, in particular, artificial intelligence may provide clinical and mechanistic insights, address bias in clinical studies, and facilitate education and implementation science to improve cardiovascular and stroke outcomes. Last, a key objective of this scientific statement is to further the field by identifying best practices, gaps, and challenges for interested stakeholders.


Subject(s)
Cardiovascular Diseases , Heart Diseases , Stroke , United States , Humans , Artificial Intelligence , American Heart Association , Cardiovascular Diseases/therapy , Cardiovascular Diseases/prevention & control , Stroke/diagnosis , Stroke/prevention & control
9.
Circ Arrhythm Electrophysiol ; 17(3): e012041, 2024 03.
Article in English | MEDLINE | ID: mdl-38348685

ABSTRACT

BACKGROUND: Atrial fibrillation is the most common cardiac arrhythmia in the world and increases the risk for stroke and morbidity. During atrial fibrillation, the electric activation fronts are no longer coherently propagating through the tissue and, instead, show rotational activity, consistent with spiral wave activation, focal activity, collision, or partial versions of these spatial patterns. An unexplained phenomenon is that although simulations of cardiac models abundantly demonstrate spiral waves, clinical recordings often show only intermittent spiral wave activity. METHODS: In silico data were generated using simulations in which spiral waves were continuously created and annihilated and in simulations in which a spiral wave was intermittently trapped at a heterogeneity. Clinically, spatio-temporal activation maps were constructed using 60 s recordings from a 64 electrode catheter within the atrium of N=34 patients (n=24 persistent atrial fibrillation). The location of clockwise and counterclockwise rotating spiral waves was quantified and all intervals during which these spiral waves were present were determined. For each interval, the angle of rotation as a function of time was computed and used to determine whether the spiral wave returned in step or changed phase at the start of each interval. RESULTS: In both simulations, spiral waves did not come back in phase and were out of step." In contrast, spiral waves returned in step in the majority (68%; P=0.05) of patients. Thus, the intermittently observed rotational activity in these patients is due to a temporally and spatially conserved spiral wave and not due to ones that are newly created at the onset of each interval. CONCLUSIONS: Intermittency of spiral wave activity represents conserved spiral wave activity of long, but interrupted duration or transient spiral activity, in the majority of patients. This finding could have important ramifications for identifying clinically important forms of atrial fibrillation and in guiding treatment.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/diagnosis , Heart Atria , Catheters , Cardiac Conduction System Disease , Computer Simulation
10.
J Interv Card Electrophysiol ; 67(1): 111-118, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37256462

ABSTRACT

BACKGROUND: Tyrosine kinase inhibitors (TKIs) are widely used in the treatment of hematologic malignancies. Limited studies have shown an association between treatment-limiting arrhythmias and TKI, particularly ibrutinib, a Bruton's tyrosine kinase (BTK) inhibitor. We sought to comprehensively assess the arrhythmia burden in patients receiving ibrutinib vs non-BTK TKI vs non-TKI therapies. METHODS: We performed a retrospective analysis of consecutive patients who received long-term cardiac event monitors while on ibrutinib, non-BTK TKIs, or non-TKI therapy for a hematologic malignancy between 2014 and 2022. RESULTS: One hundred ninety-three patients with hematologic malignancies were included (ibrutinib = 72, non-BTK TKI = 46, non-TKI therapy = 75). The average duration of TKI therapy was 32 months in the ibrutinib group vs 64 months in the non-BTK TKI group (p = 0.003). The ibrutinib group had a higher prevalence of atrial fibrillation (n = 32 [44%]) compared to the non-BTK TKI (n = 7 [15%], p = 0.001) and non-TKI (n = 15 [20%], p = 0.002) groups. Similarly, the prevalence of non-sustained ventricular tachycardia was higher in the ibrutinib group (n = 31, 43%) than the non-BTK TKI (n = 8 [17%], p = 0.004) and non-TKI groups (n = 20 [27%], p = 0.04). TKI therapy was held in 25% (n = 18) of patients on ibrutinib vs 4% (n = 2) on non-BTK TKIs (p = 0.005) secondary to arrhythmias. CONCLUSIONS: In this large retrospective analysis of patients with hematologic malignancies, patients receiving ibrutinib had a higher prevalence of atrial and ventricular arrhythmias compared to those receiving other TKI, with a higher rate of treatment interruption due to arrhythmias.


Subject(s)
Atrial Fibrillation , Hematologic Neoplasms , Humans , Agammaglobulinaemia Tyrosine Kinase , Retrospective Studies , Atrial Fibrillation/drug therapy , Atrial Fibrillation/epidemiology
11.
EBioMedicine ; 99: 104937, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38118401

ABSTRACT

BACKGROUND: Risk stratification for ventricular arrhythmias currently relies on static measurements that fail to adequately capture dynamic interactions between arrhythmic substrate and triggers over time. We trained and internally validated a dynamic machine learning (ML) model and neural network that extracted features from longitudinally collected electrocardiograms (ECG), and used these to predict the risk of malignant ventricular arrhythmias. METHODS: A multicentre study in patients implanted with an implantable cardioverter-defibrillator (ICD) between 2007 and 2021 in two academic hospitals was performed. Variational autoencoders (VAEs), which combine neural networks with variational inference principles, and can learn patterns and structure in data without explicit labelling, were trained to encode the mean ECG waveforms from the limb leads into 16 variables. Supervised dynamic ML models using these latent ECG representations and clinical baseline information were trained to predict malignant ventricular arrhythmias treated by the ICD. Model performance was evaluated on a hold-out set, using time-dependent receiver operating characteristic (ROC) and calibration curves. FINDINGS: 2942 patients (61.7 ± 13.9 years, 25.5% female) were included, with a total of 32,129 ECG recordings during a mean follow-up of 43.9 ± 35.9 months. The mean time-varying area under the ROC curve for the dynamic model was 0.738 ± 0.07, compared to 0.639 ± 0.03 for a static (i.e. baseline-only model). Feature analyses indicated dynamic changes in latent ECG representations, particularly those affecting the T-wave morphology, were of highest importance for model predictions. INTERPRETATION: Dynamic ML models and neural networks effectively leverage routinely collected longitudinal ECG recordings for personalised and updated predictions of malignant ventricular arrhythmias, outperforming static models. FUNDING: This publication is part of the project DEEP RISK ICD (with project number 452019308) of the research programme Rubicon which is (partly) financed by the Dutch Research Council (NWO). This research is partly funded by the Amsterdam Cardiovascular Sciences (personal grant F.V.Y.T).


Subject(s)
Defibrillators, Implantable , Humans , Female , Male , Death, Sudden, Cardiac , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Electrocardiography , Neural Networks, Computer
12.
Circ Heart Fail ; 17(1): e010879, 2024 01.
Article in English | MEDLINE | ID: mdl-38126168

ABSTRACT

BACKGROUND: Deep learning models may combat widening racial disparities in heart failure outcomes through early identification of individuals at high risk. However, demographic biases in the performance of these models have not been well-studied. METHODS: This retrospective analysis used 12-lead ECGs taken between 2008 and 2018 from 326 518 patient encounters referred for standard clinical indications to Stanford Hospital. The primary model was a convolutional neural network model trained to predict incident heart failure within 5 years. Biases were evaluated on the testing set (160 312 ECGs) using the area under the receiver operating characteristic curve, stratified across the protected attributes of race, ethnicity, age, and sex. RESULTS: There were 59 817 cases of incident heart failure observed within 5 years of ECG collection. The performance of the primary model declined with age. There were no significant differences observed between racial groups overall. However, the primary model performed significantly worse in Black patients aged 0 to 40 years compared with all other racial groups in this age group, with differences most pronounced among young Black women. Disparities in model performance did not improve with the integration of race, ethnicity, sex, and age into model architecture, by training separate models for each racial group, or by providing the model with a data set of equal racial representation. Using probability thresholds individualized for race, age, and sex offered substantial improvements in F1 scores. CONCLUSIONS: The biases found in this study warrant caution against perpetuating disparities through the development of machine learning tools for the prognosis and management of heart failure. Customizing the application of these models by using probability thresholds individualized by race, ethnicity, age, and sex may offer an avenue to mitigate existing algorithmic disparities.


Subject(s)
Deep Learning , Heart Failure , Humans , Female , Heart Failure/diagnosis , Heart Failure/therapy , Retrospective Studies , Ethnicity , Electrocardiography
13.
Interface Focus ; 13(6): 20230038, 2023 Dec 06.
Article in English | MEDLINE | ID: mdl-38106921

ABSTRACT

To enable large in silico trials and personalized model predictions on clinical timescales, it is imperative that models can be constructed quickly and reproducibly. First, we aimed to overcome the challenges of constructing cardiac models at scale through developing a robust, open-source pipeline for bilayer and volumetric atrial models. Second, we aimed to investigate the effects of fibres, fibrosis and model representation on fibrillatory dynamics. To construct bilayer and volumetric models, we extended our previously developed coordinate system to incorporate transmurality, atrial regions and fibres (rule-based or data driven diffusion tensor magnetic resonance imaging (MRI)). We created a cohort of 1000 biatrial bilayer and volumetric models derived from computed tomography (CT) data, as well as models from MRI, and electroanatomical mapping. Fibrillatory dynamics diverged between bilayer and volumetric simulations across the CT cohort (correlation coefficient for phase singularity maps: left atrial (LA) 0.27 ± 0.19, right atrial (RA) 0.41 ± 0.14). Adding fibrotic remodelling stabilized re-entries and reduced the impact of model type (LA: 0.52 ± 0.20, RA: 0.36 ± 0.18). The choice of fibre field has a small effect on paced activation data (less than 12 ms), but a larger effect on fibrillatory dynamics. Overall, we developed an open-source user-friendly pipeline for generating atrial models from imaging or electroanatomical mapping data enabling in silico clinical trials at scale (https://github.com/pcmlab/atrialmtk).

14.
Nat Biomed Eng ; 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38012305

ABSTRACT

Prolonged tachycardia-a risk factor for cardiovascular morbidity and mortality-can induce cardiomyopathy in the absence of structural disease in the heart. Here, by leveraging human patient data, a canine model of tachycardia and engineered heart tissue generated from human induced pluripotent stem cells, we show that metabolic rewiring during tachycardia drives contractile dysfunction by promoting tissue hypoxia, elevated glucose utilization and the suppression of oxidative phosphorylation. Mechanistically, a metabolic shift towards anaerobic glycolysis disrupts the redox balance of nicotinamide adenine dinucleotide (NAD), resulting in increased global protein acetylation (and in particular the acetylation of sarcoplasmic/endoplasmic reticulum Ca2+-ATPase), a molecular signature of heart failure. Restoration of NAD redox by NAD+ supplementation reduced sarcoplasmic/endoplasmic reticulum Ca2+-ATPase acetylation and accelerated the functional recovery of the engineered heart tissue after tachycardia. Understanding how metabolic rewiring drives tachycardia-induced cardiomyopathy opens up opportunities for therapeutic intervention.

16.
Front Cardiovasc Med ; 10: 1189293, 2023.
Article in English | MEDLINE | ID: mdl-37849936

ABSTRACT

Background: Segmentation of computed tomography (CT) is important for many clinical procedures including personalized cardiac ablation for the management of cardiac arrhythmias. While segmentation can be automated by machine learning (ML), it is limited by the need for large, labeled training data that may be difficult to obtain. We set out to combine ML of cardiac CT with domain knowledge, which reduces the need for large training datasets by encoding cardiac geometry, which we then tested in independent datasets and in a prospective study of atrial fibrillation (AF) ablation. Methods: We mathematically represented atrial anatomy with simple geometric shapes and derived a model to parse cardiac structures in a small set of N = 6 digital hearts. The model, termed "virtual dissection," was used to train ML to segment cardiac CT in N = 20 patients, then tested in independent datasets and in a prospective study. Results: In independent test cohorts (N = 160) from 2 Institutions with different CT scanners, atrial structures were accurately segmented with Dice scores of 96.7% in internal (IQR: 95.3%-97.7%) and 93.5% in external (IQR: 91.9%-94.7%) test data, with good agreement with experts (r = 0.99; p < 0.0001). In a prospective study of 42 patients at ablation, this approach reduced segmentation time by 85% (2.3 ± 0.8 vs. 15.0 ± 6.9 min, p < 0.0001), yet provided similar Dice scores to experts (93.9% (IQR: 93.0%-94.6%) vs. 94.4% (IQR: 92.8%-95.7%), p = NS). Conclusions: Encoding cardiac geometry using mathematical models greatly accelerated training of ML to segment CT, reducing the need for large training sets while retaining accuracy in independent test data. Combining ML with domain knowledge may have broad applications.

17.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37712675

ABSTRACT

AIMS: Left ventricular ejection fraction (LVEF) is suboptimal as a sole marker for predicting sudden cardiac death (SCD). Machine learning (ML) provides new opportunities for personalized predictions using complex, multimodal data. This study aimed to determine if risk stratification for implantable cardioverter-defibrillator (ICD) implantation can be improved by ML models that combine clinical variables with 12-lead electrocardiograms (ECG) time-series features. METHODS AND RESULTS: A multicentre study of 1010 patients (64.9 ± 10.8 years, 26.8% female) with ischaemic, dilated, or non-ischaemic cardiomyopathy, and LVEF ≤ 35% implanted with an ICD between 2007 and 2021 for primary prevention of SCD in two academic hospitals was performed. For each patient, a raw 12-lead, 10-s ECG was obtained within 90 days before ICD implantation, and clinical details were collected. Supervised ML models were trained and validated on a development cohort (n = 550) from Hospital A to predict ICD non-arrhythmic mortality at three-year follow-up (i.e. mortality without prior appropriate ICD-therapy). Model performance was evaluated on an external patient cohort from Hospital B (n = 460). At three-year follow-up, 16.0% of patients had died, with 72.8% meeting criteria for non-arrhythmic mortality. Extreme gradient boosting models identified patients with non-arrhythmic mortality with an area under the receiver operating characteristic curve (AUROC) of 0.90 [95% confidence intervals (CI) 0.80-1.00] during internal validation. In the external cohort, the AUROC was 0.79 (95% CI 0.75-0.84). CONCLUSIONS: ML models combining ECG time-series features and clinical variables were able to predict non-arrhythmic mortality within three years after device implantation in a primary prevention population, with robust performance in an independent cohort.


Subject(s)
Defibrillators, Implantable , Humans , Female , Male , Patient Selection , Stroke Volume , Ventricular Function, Left , Machine Learning , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Primary Prevention
18.
Europace ; 25(8)2023 08 25.
Article in English | MEDLINE | ID: mdl-37622574

ABSTRACT

AIMS: Over the past 25 years there has been a substantial development in the field of digital electrophysiology (EP) and in parallel a substantial increase in publications on digital cardiology.In this celebratory paper, we provide an overview of the digital field by highlighting publications from the field focusing on the EP Europace journal. RESULTS: In this journey across the past quarter of a century we follow the development of digital tools commonly used in the clinic spanning from the initiation of digital clinics through the early days of telemonitoring, to wearables, mobile applications, and the use of fully virtual clinics. We then provide a chronicle of the field of artificial intelligence, a regulatory perspective, and at the end of our journey provide a future outlook for digital EP. CONCLUSION: Over the past 25 years Europace has published a substantial number of papers on digital EP, with a marked expansion in digital publications in recent years.


Subject(s)
Cardiology , Mobile Applications , Humans , Artificial Intelligence , Cardiac Electrophysiology , Cognition
20.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-36932716

ABSTRACT

AIMS: There is a clinical spectrum for atrial tachyarrhythmias wherein most patients with atrial tachycardia (AT) and some with atrial fibrillation (AF) respond to ablation, while others do not. It is undefined if this clinical spectrum has pathophysiological signatures. This study aims to test the hypothesis that the size of spatial regions showing repetitive synchronized electrogram (EGM) shapes over time reveals a spectrum from AT, to AF patients who respond acutely to ablation, to AF patients without acute response. METHODS AND RESULTS: We studied n = 160 patients (35% women, 65.0 ± 10.4 years) of whom (i) n = 75 had AF terminated by ablation propensity matched to (ii) n = 75 without AF termination and (iii) n = 10 with AT. All patients had mapping by 64-pole baskets to identify areas of repetitive activity (REACT) to correlate unipolar EGMs in shape over time. Synchronized regions (REACT) were largest in AT, smaller in AF termination, and smallest in non-termination cohorts (0.63 ± 0.15, 0.37 ± 0.22, and 0.22 ± 0.18, P < 0.001). Area under the curve for predicting AF termination in hold-out cohorts was 0.72 ± 0.03. Simulations showed that lower REACT represented greater variability in clinical EGM timing and shape. Unsupervised machine learning of REACT and extensive (50) clinical variables yielded four clusters of increasing risk for AF termination (P < 0.01, χ2), which were more predictive than clinical profiles alone (P < 0.001). CONCLUSION: The area of synchronized EGMs within the atrium reveals a spectrum of clinical response in atrial tachyarrhythmias. These fundamental EGM properties, which do not reflect any predetermined mechanism or mapping technology, predict outcome and offer a platform to compare mapping tools and mechanisms between AF patient groups.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Female , Male , Catheter Ablation/methods , Heart Atria , Atrial Fibrillation/surgery , Tachycardia
SELECTION OF CITATIONS
SEARCH DETAIL
...