Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Radiat Res ; 55(3): 600-7, 2014 May.
Article in English | MEDLINE | ID: mdl-24385469

ABSTRACT

A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy of dose calculation in radiation treatment-planning systems was surveyed in participating institutions, and differences in the irradiating dose between the institutions were investigated. We developed a water tank-type lung phantom appropriate for verification of the exposure dose in lung SBRT. Using this water tank-type lung phantom, the dose calculated in the radiation treatment-planning system and the measured dose using a free air ionization chamber and dosimetric film were compared in a visiting survey of the seven institutions participating in the clinical study. In all participating institutions, differences between the calculated and the measured dose in the irradiation plan were as follows: the accuracy of the absolute dose in the center of the simulated tumor measured using a free air ionization chamber was within 2%, the mean gamma value was ≤ 0.47 on gamma analysis following the local dose criteria, and the pass rate was >87% for 3%/3 mm from measurement of dose distribution with dosimetric film. These findings confirmed the accuracy of delivery doses in the institutions participating in the clinical study, so that a study with integration of the institutions could be initiated.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Phantoms, Imaging/standards , Radiometry/instrumentation , Radiometry/standards , Radiosurgery/standards , Equipment Design , Equipment Failure Analysis , Humans , Japan , Reproducibility of Results , Sensitivity and Specificity , Water
2.
Phys Med Biol ; 51(21): 5409-17, 2006 Nov 07.
Article in English | MEDLINE | ID: mdl-17047260

ABSTRACT

A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to minimize the variations of the prescription dose between the institutions. We visited the 16 participating institutions and examined the absolute dose at the centre of a simulated spherical tumour of 3.0 cm diameter in the lung using the radiation treatment planning systems in each institution. A lung phantom for stereotactic body radiotherapy (SBRT) was developed and used for the treatment planning and film dosimetry. In the JCOG radiotherapy study group, the no model-based calculation algorithm or the model-based calculation algorithm with a dose kernel unscaled for heterogeneities were selected for use in the initial SBRT trials started in 2004, and the model-based calculation algorithm with a dose kernel scaled for heterogeneities was selected for the coming trial. The findings of this study suggest that the clinical results of lung SBRT trials should be carefully evaluated in comparison with the actual dose given to patients.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Radiometry/instrumentation , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/methods , Algorithms , Dose Fractionation, Radiation , Humans , Lung/diagnostic imaging , Lung/pathology , Phantoms, Imaging , Radiography , Radiotherapy Dosage , Radiotherapy, Conformal/instrumentation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...