Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
CEN Case Rep ; 11(1): 1-5, 2022 02.
Article in English | MEDLINE | ID: mdl-34218419

ABSTRACT

Chylous ascites is a rare, potentially sinister complication in post donor nephrectomy patients which may cause significant morbidity in form of severe malnutrition and an immuno-compromised state. We present two patients with post donor nephrectomy-related chylous leaks who failed conservative treatment. In both cases, lymphangiography was done first to detect the chylous leak site in the left renal fossa, and thereafter transvenous retrograde approach via left subclavian vein with selective lymphatic duct embolization of chylous leak was done with coils and glue successfully. Chylous ascites resolved in both patients after the embolization. Hence retrograde transvenous embolization technique appears to be an effective management option for refractory chylous leaks.


Subject(s)
Chylous Ascites , Embolization, Therapeutic , Chylous Ascites/surgery , Chylous Ascites/therapy , Embolization, Therapeutic/methods , Humans , Kidney , Lymphography/adverse effects , Lymphography/methods , Nephrectomy/adverse effects
2.
JNMA J Nepal Med Assoc ; 57(218): 272-274, 2019.
Article in English | MEDLINE | ID: mdl-32323662

ABSTRACT

Iatrogenic complications due to renal biopsy majorly include formation of an arterio-venous fistula, pseudoaneurysm or arterio-ureteral fistula. These complications are observed within a span of few days post biopsy and are rare after few years. We reported a case of 32-year-old renal allograft recipient male presenting 6 years post biopsy of the left kidney with left lumbar region pain who was eventually diagnosed with arterio-venous fistula and pseudoaneurysm involving inferior interlobular branch of left renal artery. Superselective embolization was achieved using coils and high concentration glue and transient placement of a venous occlusion balloon with complete technical and clinical success. Keywords: renal arterio-venous fistula; renal biopsy; renal pseudoaneurysm.


Subject(s)
Aneurysm, False/diagnosis , Arteriovenous Fistula/diagnosis , Kidney Transplantation , Kidney/pathology , Adult , Aneurysm, False/therapy , Arteriovenous Fistula/therapy , Biopsy/adverse effects , Biopsy/methods , Embolization, Therapeutic/methods , Humans , Male , Renal Artery/pathology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL