1.
J Magn Reson ; 237: 79-84, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24161681

ABSTRACT

Cryogenic probes have significantly increased the sensitivity of NMR. Here, we present a compact EPR receiver design capable of cryogenic operation. Compared to room temperature operation, it reduces the noise by a factor of ≈2.5. We discuss in detail the design and analyze the resulting noise performance. At low microwave power, the input noise density closely follows the emission of a cooled 50Ω resistor over the whole measurement range from 20K up to room temperature. To minimize the influence of the microwave source noise, we use high microwave efficiency (≈1.1-1.7mTW(-1/2)) planar microresonators. Their efficient conversion of microwave power to magnetic field permits EPR measurements with very low power levels, typically ranging from a few µW down to fractions of nW.

2.
Nanotechnology ; 22(29): 295713, 2011 Jul 22.
Article in English | MEDLINE | ID: mdl-21693797

ABSTRACT

The design of future spintronic devices requires a quantitative understanding of the microscopic linear and nonlinear spin relaxation processes governing the magnetization reversal in nanometer-scale ferromagnetic systems. Ferromagnetic resonance is the method of choice for a quantitative analysis of relaxation rates, magnetic anisotropy and susceptibility in a single experiment. The approach offers the possibility of coherent control and manipulation of nanoscaled structures by microwave irradiation. Here, we analyze the different excitation modes in a single nanometer-sized ferromagnetic stripe. Measurements are performed using a microresonator set-up which offers a sensitivity to quantitatively analyze the dynamic and static magnetic properties of single nanomagnets with volumes of (100 nm)(3). Uniform as well as non-uniform volume modes of the spin wave excitation spectrum are identified and found to be in excellent agreement with the results of micromagnetic simulations which allow the visualization of the spatial distribution of these modes in the nanostructures.

3.
Rev Sci Instrum ; 79(8): 084702, 2008 Aug.
Article in English | MEDLINE | ID: mdl-19044371

ABSTRACT

Electron spin resonance (ESR) of volume-limited samples or nanostructured materials can be made significantly more efficient by using microresonators whose size matches that of the structures under investigation. We describe a series of planar microresonators that show large improvements over conventional ESR resonators in terms of microwave conversion efficiency (microwave field strength for a given input power) and sensitivity (minimum number of detectable spins). We explore the dependence of these parameters on the size of the resonator and find that both scale almost linearly with the inverse of the resonator size. Scaling down the loops of the planar microresonators from 500 down to 20 mum improves the microwave efficiency and the sensitivity of these structures by more than an order of magnitude and reduces the microwave power requirements by more than two orders of magnitude.

4.
J Magn Reson ; 175(2): 275-84, 2005 Aug.
Article in English | MEDLINE | ID: mdl-15939642

ABSTRACT

EPR resonators on the basis of standing-wave cavities are optimised for large samples. For small samples it is possible to design different resonators that have much better power handling properties and higher sensitivity. Other parameters being equal, the sensitivity of the resonator can be increased by minimising its size and thus increasing the filling factor. Like in NMR, it is possible to use lumped elements; coils can confine the microwave field to volumes that are much smaller than the wavelength. We discuss the design and evaluation of EPR resonators on the basis of planar microcoils. Our test resonators, which operate at a frequency of 14 GHz, have excellent microwave efficiency factors, achieving 24 ns pi/2 EPR pulses with an input power of 17 mW. The sensitivity tests with DPPH samples resulted in the sensitivity value 2.3 x 10(9) spins.G(-1) Hz(-1/2) at 300 K.