Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
Am J Ophthalmol ; 227: 245-253, 2021 07.
Article in English | MEDLINE | ID: mdl-33823160

ABSTRACT

PURPOSE: The intent of this study was to determine the diagnostic accuracy of several diagnostic tests for age-related macular degeneration (AMD), diabetic retinopathy (DR), glaucoma, and cataract, as well as the proportions of patients with eye disease from each of 3 enrolling clinics. DESIGN: Diagnostic accuracy study. METHODS: Patients ≥50 years old in a diabetes, thyroid, and general medicine clinic were screened using visual acuity, tonometry, and fundus photography. Photographs were graded at the point-of-screening by non-ophthalmic personnel. Participants with positive screening test results in either eye and a 10% random sample with negative results in both eyes were referred for an in-person, reference-standard ophthalmology examination. RESULTS: Of 889 participants enrolled, 229 participants failed at least 1 test in either eye, of which 189 presented for an ophthalmic examination. An additional 76 participants with completely normal screening test results were referred for examination, of which 50 attended. Fundus photography screening had the highest yield for DR (sensitivity: 67%; 95% confidence interval [CI]: 39%-87%), visual acuity screening for cataract (sensitivity: 89%; 95% CI: 86%-92%), and intraocular pressure screening for glaucoma or suspected glaucoma (sensitivity: 25%; 95% CI: 14%-40%). The burden of disease was relatively high in all 3 clinics, with at least 1 of the diseases of interest (ie, AMD, DR, glaucoma or suspected glaucoma, or cataract) detected in 25% of participants (95% CI: 17-35%) from the diabeteses clinic, 34% (95% CI: 22%-49%) from the thyroid clinic, and 21% (95% CI: 13%-32%) from the general clinic. CONCLUSIONS: Non-expert eye disease screening in health clinics may be a useful model for detection of eye disease in resource-limited settings.


Subject(s)
Diagnostic Techniques, Ophthalmological , Eye Diseases/diagnostic imaging , Ophthalmologists/standards , Photography/methods , Physician Assistants/standards , Aged , Cataract/diagnostic imaging , Clinical Competence , Diabetic Retinopathy/diagnostic imaging , Female , Glaucoma/diagnostic imaging , Humans , Intraocular Pressure/physiology , Macular Degeneration/diagnostic imaging , Male , Middle Aged , Ophthalmoscopy , Prospective Studies , Reproducibility of Results , Slit Lamp Microscopy , Vision Screening/instrumentation , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL