Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Strength Cond Res ; 37(12): 2373-2380, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38015729

ABSTRACT

ABSTRACT: Makaraci, Y, Nas, K, Ruiz-Cárdenas, JD, Gündüz, K, Aydemir, M, and Orange, ST. Test-retest reliability and convergent validity of piezoelectric force plate measures of single-leg sit-to-stand performance in trained adults. J Strength Cond Res 37(12): 2373-2380, 2023-The single-leg sit-to-stand (STS) test has emerged as a promising method of assessing lower-limb functional strength and asymmetry. However, the reliability of its performance parameters on a force plate has not been explored. This study examined the test-retest reliability and convergent validity of the single-leg STS test performed on a piezoelectric-based force plate in trained subjects. Thirty trained male adults (age: 21.4 ± 1.7 years) performed 3 separate single-leg STS days of testing to assess both intraday and interday reliability. Performance parameters included STS time, ground reaction force (GRF), and center of pressure (CoP) sway velocity. The relationship between single-leg STS parameters and unilateral countermovement jump (CMJ) variables was assessed for convergent validity. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were calculated for reliability analyses, and convergent validity was assessed with Spearman's correlation coefficient (ρ). In the dominant leg, single-leg performance parameters showed moderate-to-excellent intraday reliability (ICC = 0.65-0.90, CV = 4.3-11.2%) and moderate interday reliability (ICC = 0.54-0.74, CV = 5.8-13.5%). In the nondominant leg, all single-leg STS performance parameters showed good intraday (ICC = 0.79-0.86, CV = 3.8-9.8%) and interday reliability (ICC = 0.75-0.82, CV = 4.6-9.7%). STS times in the dominant and nondominant legs were inversely related to unilateral CMJ velocity (ρ = -0.47 and -0.38, respectively). CoP sway velocity in the nondominant leg showed positive correlations with unilateral CMJ power and velocity (ρ = 0.38 and 0.54, respectively). In conclusion, the force plate-based single-leg STS test provides reliable measures of STS time, GRF, and CoP sway velocity in trained adults and could be used to assess lower-limb function and asymmetry.


Subject(s)
Exercise Test , Leg , Humans , Adult , Male , Young Adult , Reproducibility of Results , Exercise Test/methods , Muscle Strength
2.
J Exerc Rehabil ; 18(5): 308-317, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36420474

ABSTRACT

This study aims to examine the relationship between postural perfor-mance, physical fitness level, and shooting performance in Olympic fe-male goalball players. Eight Olympic-level goalball players (age: 20.63± 4.37 years) were recruited from the Turkish National Women's Goalball Team. Postural stability, physical fitness, and shooting performance of the players were measured. The postural stability was determined us-ing body sway measurements during parallel and single-leg stances on a force plate. The physical fitness level of the players is evaluated by curl-up, isometric push-up, trunk lift, and grip strength (dominant hand) tests. A goalball-specific shooting accuracy test was used for shooting performance. Independent sample t-test and Pearson correlation were used for statistical processing. No statistical difference was observed in body sway parameters between open eyes and closed eyes condi-tions except for the anteroposterior sway area. Some of the body sway parameters performed under different stances positively correlated with all physical fitness tests (P<0.05). There was a positive correlation between the shooting accuracy and trunk lift score (r=0.767). Right leg sway area anterior-posterior and ellipse area negatively correlated with shooting accuracy (r=-0.629 and r=-0.692 respectively). It is necessary to attach importance to the improvement of the physical fitness level specific to core strength to maintain postural stability for visually im-paired athletes. In our study, some factors affecting shooting accuracy were identified, but it is necessary not to restrict a complex structure such as shooting accuracy within certain concepts.

SELECTION OF CITATIONS
SEARCH DETAIL