Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
JACC Cardiovasc Interv ; 16(23): 2854-2865, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37999708

ABSTRACT

BACKGROUND: A significant number of patients with severe mitral regurgitation (MR) are not suitable for either surgical or transcatheter edge-to-edge repair because of high surgical risk or inappropriate mitral valve anatomy. OBJECTIVES: The aim of this study was to evaluate the HighLife Trans-Septal Mitral Valve Replacement (TSMVR) system in patients with symptomatic MR and high surgical risk. METHODS: This prospective, multicenter, nonrandomized feasibility study evaluated the safety and performance of the HighLife TSMVR system in patients with moderate to severe or severe symptomatic MR during 1-year follow-up. Echocardiographic data were assessed at an independent core laboratory. RESULTS: A total of 30 patients (mean age 75.6 years, 27% women, median Society of Thoracic Surgeons score 5.5%) with severe MR (90% with secondary MR, median left ventricular ejection fraction 43%) were treated at 13 sites. In 27 of the 30 patients, the HighLife TSMVR system was implanted successfully (technical success rate 90%). Device success at 30 days was 83%. After 1 year, 5 patients (17%) had died. None of the patients who underwent implantation required mitral valve reintervention. All patients who underwent implantation had no or trace (78%) or mild (22%) MR, the mean gradient of the HighLife valve was 5.1 mm Hg, and there were no signs of left ventricular outflow tract obstruction (mean gradient 2.0 mm Hg). CONCLUSIONS: The 1-year results from the HighLife TSMVR feasibility study demonstrate a high technical success rate, excellent valve function, no left ventricular outflow tract obstruction, and no need for mitral valve reintervention. Additional patient outcomes and longer follow-up are needed to confirm these findings. (Expanded Study of the HighLife 28mm Trans-Septal Trans-Catheter Mitral Valve in Patients With Moderate-Severe or Severe Mitral Regurgitation and at High Surgical Risk; NCT04029363).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Aged , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Stroke Volume , Feasibility Studies , Prospective Studies , Ventricular Function, Left , Treatment Outcome , Cardiac Catheterization
SELECTION OF CITATIONS
SEARCH DETAIL
...