Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add more filters










Publication year range
1.
J Biomech ; 129: 110812, 2021 12 02.
Article in English | MEDLINE | ID: mdl-34688063

ABSTRACT

A cochlear implant is an electronic device implanted into the cochlea to directly stimulate the auditory nerve. Such device is used in patients with severe-to-profound hearing loss. The cochlear implant surgery is safe, but involves some risks, such as infections, device malfunction or damage of the facial nerve and it can result on a poor hearing outcome, due to the destruction of any present residual hearing. Future improvements in cochlear implant surgery will necessarily involve the decrease of the intra-cochlear damage. Several implant related variables, such as materials, geometrical design, processor and surgical techniques can be optimized in order for the patients to partially recover their hearing capacities The straight electrode is a type of cochlear implant that many authors indicate as being the less traumatic. From the finite element analysis conducted in this work, the influence of the insertion speed, the friction coefficient between the cochlear wall and the electrode array, and several configurations of the cochlear implant tip were studied. The numerical simulations of the implantation showed the same pattern of the insertion force against insertion depth, thus indicating the different phases of the insertion. Results demonstrated that lower insertion speeds, friction coefficients and tip stiffness, led to a reduction on the contact pressures and insertion force. It is expected that these improved configurations will allow to preserve the residual hearing while reducing surgical complications.


Subject(s)
Cochlear Implantation , Cochlear Implants , Cochlea/surgery , Finite Element Analysis , Hearing , Humans
2.
J Biomech ; 127: 110649, 2021 10 11.
Article in English | MEDLINE | ID: mdl-34375905

ABSTRACT

The female pelvic cavity involves muscles, ligaments, endopelvic fasciae and multiple organs where different pathologies may occur, namely the pelvic organ prolapse (POP). The synthetic implants are used for the reconstructive surgery of POP, but severe complications associated with their use have been reported, mainly related to their mechanical properties (e.g., implant stiffness) and microstructure. In this study, we mimicked a transvaginal reconstructive surgery to repair the apical ligaments (uterosacral ligaments (USLs) and cardinal ligaments (CLs)), by modeling, their impairment (90% and 50%) and/or total rupture. The implants to reinforce/replace these ligaments were built based on literature specifications and their mechanical properties were obtained through uniaxial tensile tests. The main aim of this study was to simulate the effect of mesh anchoring technique (simple stich and continuous stitch), and compare the displacement magnitude of the pelvic tissues, during Valsalva maneuver. The absence/presence of the synthetic implant was simulated when total rupture of the CLs and USLs occurs, causing a variation of the vaginal displacement (9% for the CLs and 27% for the USLs). Additionally, the simulations showed that there was a variation of the supero-inferior displacement of the vaginal wall between different anchoring techniques (simple stich and continuous stitch) being approximately of 10% for the simulation USLs and CLs implant. The computational simulation was able to mimic the biomechanical behavior of the USLs and CLs, in response to different anchoring techniques, which can be help improving the outcomes of the prolapse surgery.


Subject(s)
Pelvic Organ Prolapse , Uterine Prolapse , Female , Finite Element Analysis , Humans , Ligaments/surgery , Pelvic Organ Prolapse/surgery , Surgical Mesh , Treatment Outcome
3.
Biomech Model Mechanobiol ; 20(4): 1495-1507, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33900492

ABSTRACT

This work proposes a novel tissue-scale mechanobiological model of bone remodeling to study bone's adaptation to distinct loading conditions. The devised algorithm describes the mechanosensitivity of bone and its impact on bone cells' functioning through distinct signaling factors. In this study, remodeling is mechanically ruled by variations of the strain energy density (SED) of bone, which is determined by performing a linear elastostatic analysis combined with the finite element method. Depending on the SED levels and on a set of biological signaling factors ([Formula: see text] parameters), osteoclasts and osteoblasts can be mechanically triggered. To reproduce this phenomenon, this work proposes a new set of [Formula: see text] parameters. The combined response of osteoclasts and osteoblasts will then affect bone's apparent density, which is correlated with other mechanical properties of bone, through a phenomenological law. Thus, this novel model proposes a constant interplay between the mechanical and biological components of the process. The spatiotemporal simulation used to validate this new approach is a benchmark example composed by two distinct phases: (1) pre-orientation and (2) load adaptation. On both of them, bone is able to adapt its morphology according to the loading condition, achieving the required trabecular distribution to withstand the applied loads. Moreover, the equilibrium morphology reflects the orientation of the load. These preliminary results support the new approach proposed in this study.


Subject(s)
Bone Remodeling/physiology , Bone and Bones/physiology , Osteoblasts/physiology , Osteoclasts/physiology , Stress, Mechanical , Adaptation, Physiological , Algorithms , Animals , Biomechanical Phenomena , Biophysics , Computer Simulation , Finite Element Analysis , Humans , Models, Biological
4.
Comput Biol Med ; 129: 104170, 2021 02.
Article in English | MEDLINE | ID: mdl-33352308

ABSTRACT

Bone remodeling is a highly complex process, in which bone cells interact and regulate bone's apparent density as a response to several external and internal stimuli. In this work, this process is numerically described using a novel 2D biomechanical model. Some of the new features in this model are (i) the mathematical parameters used to determine bone's apparent density and cellular density; (ii) an automatic boundary recognition step to spatially control bone remodeling and (iii) an approach to mimic the mechanical transduction to osteoclasts and osteoblasts. Moreover, this model is combined with a meshless approach - the Radial Point Interpolation Method (RPIM). The use of RPIM is an asset for this application, especially in the construction of the boundary maps. This work studies bone's adaptation to a certain loading regime through bone resorption. The signaling pathways of bone cells are dependent on the level of strain energy density (SED) in bone. So, when SED changes, bone cells' functioning is affected, causing also changes on bone's apparent density. With this model, bone is able to achieve an equilibrium state, optimizing its structure to withstand the applied loads. Results suggest that this model has the potential to provide high quality solutions while being a simpler alternative to more complex bone remodeling models in the literature.


Subject(s)
Bone Remodeling , Bone and Bones , Biomechanical Phenomena , Models, Theoretical , Osteoblasts , Osteoclasts
5.
J Mech Behav Biomed Mater ; 110: 103956, 2020 10.
Article in English | MEDLINE | ID: mdl-32957249

ABSTRACT

BACKGROUND: One of the major causes of pelvic organ prolapse is pelvic muscle injury sustained during a vaginal delivery. The most common site of this injury is where the pubovisceral muscle takes origin from the pubic bone. We hypothesized that it is possible for low-cycle material fatigue to occur at the origin of the pubovisceral muscle under the large repetitive loads associated with pushing during the second stage of a difficult labor. PURPOSE: The main goal was to test if the origin of the pubovisceral muscle accumulates material damage under sub-maximal cyclic tensile loading and identify any microscopic evidence of such damage. METHODS: Twenty origins of the ishiococcygeous muscle (homologous to the pubovisceral muscle in women) were dissected from female sheep pelvises. Four specimens were stretched to failure to characterize the failure properties of the specimens. Thirteen specimens were then subjected to relaxation and subsequent fatigue tests, while three specimens remained as untested controls. Histology was performed to check for microscopic damage accumulation. RESULTS: The fatigue stress-time curves showed continuous stress softening, a sign of material damage accumulation. Histology confirmed the presence of accumulated microdamage in the form of kinked muscle fibers and muscle fiber disruption in the areas with higher deformation, namely in the muscle near the musculotendinous junction. CONCLUSIONS: The origin of ovine ishiococcygeous muscle can accumulate damage under sub-maximal repetitive loading. The damage appears in the muscle near the musculotendinous junction and was sufficient to negatively affect the macroscopic mechanical properties of the specimens.


Subject(s)
Pelvic Floor , Pelvic Organ Prolapse , Animals , Delivery, Obstetric , Fatigue , Female , Muscle, Skeletal , Pregnancy , Sheep
6.
Acta Biomater ; 110: 175-187, 2020 07 01.
Article in English | MEDLINE | ID: mdl-32335309

ABSTRACT

The remodeling mechanisms that cause connective tissue of the vaginal wall, consisting mostly of smooth muscle, to weaken after vaginal delivery are not fully understood. Abnormal remodeling after delivery can contribute to development of pelvic organ prolapse and other pelvic floor disorders. The present study used vaginal smooth muscle cells (vSMCs) isolated from knockout mice lacking the expression of the lysyl oxidase-like1 (LOXL1) enzyme, a well-characterized animal model for pelvic organ prolapse. We tested if vaginal smooth muscle cells from LOXL1 knockout mice have altered mechanics including stiffness and surface adhesion. Using atomic force microscopy, we performed nanoindentations on both isolated and confluent cells to evaluate the effect of LOXL1 knockout on in vitro cultures of vSMCs cells from nulliparous mice. The results show that LOXL1 knockout vSMCs have increased stiffness in pre-confluent but decreased stiffness in confluent cultures (p* < 0.05) and significant decreased surface adhesion in pre-confluent cultures (p* < 0.05). This study provides evidence that the weakening of vaginal connective tissue in the absense of LOXL1 changes the mechanical properties of the vSMCs. STATEMENT OF SIGNIFICANCE: Pelvic organ prolapse is a common condition affecting millions of women worldwide, which significantly impacts their quality of life. Alterations in vaginal and pelvic floor mechanical properties can change their ability to support the pelvic organs. This study provides evidence of altered stiffness of vaginal smooth muscle cells from mice resembling pelvic organ prolapse. The results from this study set a foundation to develop pathophysiology-driven therapies focused on the interplay between smooth muscle mechanics and extracellular matrix remodeling.


Subject(s)
Protein-Lysine 6-Oxidase , Quality of Life , Amino Acid Oxidoreductases , Animals , Female , Mice , Myocytes, Smooth Muscle , Protein-Lysine 6-Oxidase/genetics , Vagina
7.
Biomech Model Mechanobiol ; 18(3): 829-843, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30635851

ABSTRACT

During vaginal delivery women sustain stretching of their pelvic floor, risking tissue injury and adverse outcomes. Since studies in pregnant women are limited with ethical constraints, computational models have become an interesting alternative to elucidate the pregnancy mechanisms. This research investigates the uterine contractions during foetus expulsion without an imposed trajectory. Such physical process is captured by means of a chemo-mechanical constitutive model, where the uterine contractions are triggered by chemical stimuli. The foetus descent, which includes both pushing and resting stages, has a descent rate within the physiological range. Moreover, the behaviour of the foetus and the uterus stretch agree well with clinical data presented in the literature. The follow-up of this study will be to obtain a complete childbirth simulation, considering also the pelvic floor muscles and its supporting structures. The simulation of a realistic rate of descent, including the pushing and resting stages, is of significant importance to study the pelvic floor muscles due to their viscoelastic nature.


Subject(s)
Computer Simulation , Fetus/physiology , Models, Biological , Uterine Contraction/physiology , Biomechanical Phenomena , Finite Element Analysis , Humans , Kinetics , Muscle, Smooth/physiology , Myosins/metabolism , Parturition/physiology , Phosphorylation , Stress, Mechanical
8.
Comput Methods Biomech Biomed Engin ; 22(1): 100-111, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30580586

ABSTRACT

In this work, an advanced discretization meshless technique is used to study the structural response of a human brain due to an impact load. The 2D and 3D brain geometrical models, and surrounding structures, were obtained through the processing of medical images, allowing to achieve a realistic geometry for the virtual model and to define the distribution of the mechanical properties accordingly with the medical images colour scale. Additionally, a set of essential and natural boundary conditions were assumed in order to reproduce a sudden impact force applied to the cranium. Then, a structural numerical analysis was performed using the Natural Neighbour Radial Point Interpolation Method (NNRPIM). The obtained results were compared with the finite element method (FEM) and a solution available in the literature. This work shows that the NNRPIM is a robust and accurate numerical technique, capable to produce results very close to other numerical approaches. In addition, the variable fields obtained with the meshless method are much smoother than the FEM corresponding solution.


Subject(s)
Brain/pathology , Numerical Analysis, Computer-Assisted , Brain Injuries, Traumatic/pathology , Finite Element Analysis , Head , Humans , Models, Anatomic , Models, Biological , Stress, Mechanical
9.
J Mech Behav Biomed Mater ; 88: 120-126, 2018 12.
Article in English | MEDLINE | ID: mdl-30170191

ABSTRACT

Injuries sustained by the pelvic floor muscles during childbirth are one of the major risk factors for the development of pelvic floor dysfunctions. The ability to predict the loss of the tissue integrity and the most affected regions prior to the childbirth would represent a compelling difference in choosing the appropriate management of labour. Previous biomechanical studies, using the finite element method, were able to simulate a vaginal delivery and analyse the mechanical effects on the pelvic floor muscles during the passage of the foetus. Complementing these studies, the aim of this work is to improve the characterization of the pelvic floor muscles, by using an anisotropic visco-hyperelastic constitutive model, including a continuum mechanics damage model. Viscoelasticity is a key feature to obtain more realistic results since biological tissues present relaxation effects that allow larger deformations without damage. This work analyses the reaction forces and the loss of tissue integrity sustained by the pelvic floor and evaluates the effects of different durations of labour. A delaying pushing technique of rest and descend is also studied in this work. The results obtained showed that the reaction forces vary with the duration of labour, with higher force levels associated with higher stretch rates. The pubovisceral muscle is the most affected of the levator ani, presenting an affected region of approximately 30%. The relaxation properties of the tissue contribute to diminish the damage levels, supporting the theory of delayed pushing applied in the second stage of labour.


Subject(s)
Delivery, Obstetric , Elasticity , Mechanical Phenomena , Models, Biological , Anisotropy , Biomechanical Phenomena , Time Factors , Viscosity
10.
J Biomech ; 71: 100-110, 2018 04 11.
Article in English | MEDLINE | ID: mdl-29454543

ABSTRACT

The mechanical characteristics of the female pelvic floor are relevant to understand pelvic floor dysfunctions (PFD), and how they are related with changes in their biomechanical behavior. Urinary incontinence (UI) and pelvic organ prolapse (POP) are the most common pathologies, which can be associated with changes in the mechanical properties of the supportive structures in the female pelvic cavity. PFD have been studied through different methods, from experimental tensile tests using tissues from fresh female cadavers or tissues collected at the time of a transvaginal hysterectomy procedure, or by applying imaging techniques. In this work, an inverse finite element analysis (FEA) was applied to understand the passive and active behavior of the pubovisceralis muscle (PVM) during Valsalva maneuver and muscle active contraction, respectively. Individual numerical models of women without pathology, with stress UI (SUI) and POP were built based on magnetic resonance images, including the PVM and surrounding structures. The passive and active material parameters obtained for a transversely isotropic hyperelastic constitutive model were estimated for the three groups. The values for the material constants were significantly higher for the women with POP when compared with the other two groups. The PVM of women with POP showed the highest stiffness. Additionally, the influence of these parameters was analyzed by evaluating their stress-strain, and force-displacements responses. The force produced by the PVM in women with POP was 47% and 82% higher when compared to women without pathology and with SUI, respectively. The inverse FEA allowed estimating the material parameters of the PVM using input information acquired non-invasively.


Subject(s)
Mechanical Phenomena , Muscle Contraction , Pelvic Floor/physiology , Pelvic Organ Prolapse/physiopathology , Urinary Incontinence, Stress/physiopathology , Adolescent , Adult , Aged , Female , Finite Element Analysis , Humans , Magnetic Resonance Imaging/methods , Middle Aged , Pelvic Floor/diagnostic imaging , Pelvic Organ Prolapse/diagnostic imaging , Urinary Incontinence , Urinary Incontinence, Stress/diagnostic imaging , Valsalva Maneuver , Young Adult
11.
Article in English | MEDLINE | ID: mdl-28886617

ABSTRACT

During vaginal delivery, women sustain stretching of their pelvic floor, risking tissue injury and adverse outcomes. Realistic numerical simulations of childbirth can help in the understanding of the pelvic floor mechanics and on the prevention of related disorders. In previous studies, biomechanical finite element simulations of a vaginal delivery have been performed disregarding the viscous effects present on all biological soft tissues. The inclusion of the viscoelastic behaviour is fundamental, since it allows to investigate rate-dependent responses. The present work uses a viscohyperelastic constitutive model to evaluate how the childbirth duration affects the efforts sustained by the pelvic floor during delivery. It was concluded that viscoelasticity adds a stiffness component that leads to higher forces comparing with the elastic response. Viscous solutions are rate dependent, and precipitous labours could be associated to higher efforts, while lower reaction forces were denoted for normal and prolonged labours, respectively. The existence of resting stages during labour demonstrated the capability of the tissue to relax and recover some of the initial properties, which helped to lower the forces and stresses involved. The present work represents a step further in achieving a robust non-invasive procedure, allowing to estimate how obstetrical factors influence labour and its outcomes.


Subject(s)
Computer Simulation , Parturition , Pelvic Floor , Adult , Female , Finite Element Analysis , Humans , Models, Biological , Pregnancy , Viscosity
12.
Comput Methods Biomech Biomed Engin ; 20(9): 958-966, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28460599

ABSTRACT

Otitis media is a group of inflammatory diseases of the middle ear. Acute otitis media and otitis media with effusion (OME) are its two main types of manifestation. Otitis media is common in children and can result in structural alterations in the middle ear which will lead to hearing losses. This work studies the effects of an OME on the sound transmission from the external auditory meatus to the inner ear. The finite element method was applied on the present biomechanical study. The numerical model used in this work was built based on the geometrical information obtained from The visible ear project. The present work explains the mechanisms by which the presence of fluid in the middle ear affects hearing by calculating the magnitude, phase and reduction of the normalized umbo velocity and also the magnitude and phase of the normalized stapes velocity. A sound pressure level of 90 dB SPL was applied at the tympanic membrane. The harmonic analysis was performed with the auditory frequency varying from 100 Hz to 10 kHz. A decrease in the response of the normalized umbo and stapes velocity as the tympanic cavity was filled with fluid was obtained. The decrease was more accentuated at the umbo.


Subject(s)
Numerical Analysis, Computer-Assisted , Otitis Media with Effusion/pathology , Acoustics , Finite Element Analysis , Humans , Otitis Media with Effusion/physiopathology , Stapes/physiopathology , Tympanic Membrane/physiopathology
13.
Comput Methods Biomech Biomed Engin ; 20(8): 842-852, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28303730

ABSTRACT

Pelvic disorders can be associated with changes in the biomechanical properties in the muscle, ligaments and/or connective tissue form fascia and ligaments. In this sense, the study of their mechanical behavior is important to understand the structure and function of these biological soft tissues. The aim of this study was to establish the biomechanical properties of the pelvic floor muscles of continent and incontinent women, using an inverse finite element analysis (FEA). The numerical models, including the pubovisceral muscle and pelvic bones were built from magnetic resonance (MR) images acquired at rest. The numerical simulation of Valsalva maneuver was based on the finite element method and the material constants were determined for different constitutive models (Neo-Hookean, Mooney-Rivlin and Yeoh) using an iterative process. The material constants (MPa) for Neo-Hookean (c1) were 0.039 ± 0.022 and 0.024 ± 0.004 for continent vs. incontinent women. For Mooney-Rivlin (c1) the values obtained were 0.026 ± 0.010 vs. 0.016 ± 0.003, and for Yeoh (c1) the values obtained were 0.031 ± 0.023 vs. 0.016 ± 0.002, (p < 0.05). Muscle displacements obtained in the numerical simulations of Valsalva maneuver were compared with the muscle displacements obtained through additional dynamic MRI. Incontinent women presented a higher antero-posterior displacement than the continent women. The results were also similar between MRI and numerical simulations (40.27% vs. 42.17% for Neo-Hookean, 39.87% for Mooney-Rivlin and 41.61% for Yeoh). Using an inverse FEA coupled with MR images allowed to obtain the in vivo biomechanical properties of the pelvic floor muscles, leading to a relationship between them for the continent and incontinent women in a non-invasive manner.


Subject(s)
Finite Element Analysis , Muscles/physiopathology , Pelvic Floor/physiopathology , Urinary Incontinence/physiopathology , Adult , Biomechanical Phenomena , Computer Simulation , Demography , Female , Humans , Magnetic Resonance Imaging , Numerical Analysis, Computer-Assisted , Stress, Mechanical
14.
Proc Inst Mech Eng H ; 230(4): 298-309, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26867781

ABSTRACT

The mechanical characteristics of the female pelvic floor are relevant when explaining pelvic dysfunction. The decreased elasticity of the tissue often causes inability to maintain urethral position, also leading to vaginal and rectal descend when coughing or defecating as a response to an increase in the internal abdominal pressure. These conditions can be associated with changes in the mechanical properties of the supportive structures-namely, the pelvic floor muscles-including impairment. In this work, we used an inverse finite element analysis to calculate the material constants for the passive mechanical behavior of the pelvic floor muscles. The numerical model of the pelvic floor muscles and bones was built from magnetic resonance axial images acquired at rest. Muscle deformation, simulating the Valsalva maneuver with a pressure of 4 KPa, was compared with the muscle displacement obtained through additional dynamic magnetic resonance imaging. The difference in displacement was of 0.15 mm in the antero-posterior direction and 3.69 mm in the supero-inferior direction, equating to a percentage error of 7.0% and 16.9%, respectively. We obtained the shortest difference in the displacements using an iterative process that reached the material constants for the Mooney-Rivlin constitutive model (c10=11.8 KPa and c20=5.53 E-02 KPa). For each iteration, the orthogonal distance between each node from the group of nodes which defined the puborectal muscle in the numerical model versus dynamic magnetic resonance imaging was computed. With the methodology used in this work, it was possible to obtain in vivo biomechanical properties of the pelvic floor muscles for a specific subject using input information acquired non-invasively.


Subject(s)
Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Pelvic Floor/diagnostic imaging , Pelvic Floor/physiology , Adult , Biomechanical Phenomena/physiology , Female , Finite Element Analysis , Humans
15.
Comput Methods Biomech Biomed Engin ; 19(3): 248-256, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25693740

ABSTRACT

This work presents a biomechanical study of myringosclerosis (MS), an abnormal condition of the ear that produces calcification of the lamina propria of the eardrum. The study researched the transfer of sound to the stapes depending on the localization, dimension and calcification degree of the MS plaques. Results were obtained using a validated finite element model of the ear. The mechanical properties of the lamina propria were modified, in order to model MS plaques, using the rule of mixtures for particle composites considering that the plaques are made of hydroxyapatite particles in a matrix of connective tissue. Results show that the localization and dimension of the plaques are a factor of higher importance than calcification for loss of hearing through MS. The mobility of the stapes decreased with the presence of larger plaques and also when the tympanic annulus and the area of the handle of the malleus were involved.


Subject(s)
Ear, Middle/physiology , Finite Element Analysis , Hearing , Tympanic Membrane/physiology , Aged , Female , Humans , Image Processing, Computer-Assisted , Models, Biological , Myringosclerosis/diagnosis , Sound , Stapes/physiology
16.
J Biomech ; 48(9): 1600-5, 2015 Jun 25.
Article in English | MEDLINE | ID: mdl-25757665

ABSTRACT

Pelvic floor injuries during vaginal delivery are considered a significant risk factor to develop pelvic floor dysfunction. The molding of the fetus head during vaginal delivery facilitates the labor progress, since it adjusts to the birth canal geometry. In this work, a finite element model was used to represent the effects induced by the passage of the fetus head on the pelvic floor. The numerical model used for this simulation included the pelvic floor muscles attached to the bones, and a fetus body. The model of the fetus head included the skin and soft tissues, the skull with sutures and fontanelles, and the brain. The fetus head movements during birth in vertex position were simulated: descent, internal rotation and extension. Two models of the fetus head were compared: a rigid and a deformable one, with the inclusion of the cranial sutures. The influence of the fetus head molding on the pelvic floor muscles was analyzed by evaluating their reaction forces, stretch, and stress and strain fields. Additionally, anatomical indices for the molding of the fetal skull were obtained and compared with clinical data. The passage of the deformable fetus head through the birth canal leads to a reduction of 17.3% on the reaction forces on the pelvic floor muscles when compared to the ones of a rigid head. Furthermore, the fetus head molding implies inferior resistance to rotation resulting in a reduction of 1.86% in muscle stretching. Quantitative evaluation of the fetus head molding showed good agreement with clinical experiments.


Subject(s)
Fetus/anatomy & histology , Muscle, Skeletal/physiology , Parturition , Pelvic Floor/physiology , Biomechanical Phenomena , Computer Simulation , Female , Finite Element Analysis , Head/anatomy & histology , Humans , Imaging, Three-Dimensional , Models, Biological , Muscle Relaxation , Pregnancy
17.
J Biomech ; 46(9): 1592-5, 2013 May 31.
Article in English | MEDLINE | ID: mdl-23598065

ABSTRACT

The present study focuses on the determination of the biomechanical properties for the human temporalis muscle. Eight pairs of temporalis muscles were collected from fresh cadavers and uniaxial traction tests were performed. Three specific regions were considered within the muscle: anterior, central and posterior. The results show that the central and posterior muscle regions are stiffer than the anterior ones. In order to interpret the different regional mechanical profiles observed in the temporalis muscle, a kinematic structural model for the muscle/joint system is proposed. Age influences the mechanical properties of the muscle, as older samples are apparently stiffer than younger ones.


Subject(s)
Temporal Muscle/physiology , Adult , Aged , Biomechanical Phenomena , Humans , Male , Middle Aged , Stress, Mechanical , Young Adult
18.
J Biomech ; 45(6): 972-7, 2012 Apr 05.
Article in English | MEDLINE | ID: mdl-22360835

ABSTRACT

The forces generated by the muscles with origin on the human femur play a major role in transtibial amputee gait, as they are the most effective of the means that the body can use for propulsion. By estimating the forces generated by the thigh muscles of transtibial amputees, and comparing them to the forces generated by the thigh muscles of normal subjects, it is possible to better estimate the energy output needed from prosthetic devices. The purpose of this paper is to obtain the forces generated by the thigh muscles of transtibial amputees and compare these with forces obtained from the same muscles in the case of normal subjects. Two transtibial amputees and four normal subjects similar in size to the amputees were investigated. Level ground walking was chosen as the movement to be studied, since it is a common activity that most amputees engage in. Inverse dynamics and a muscle recruitment algorithm (developed by AnyBody Technology(®)) were used for generating the muscle activation patterns and for computing the muscle forces. The muscle forces were estimated as two sums: one for all posterior muscles and one for the anterior muscles, based on the position of the muscles of the thigh relative to the frontal plane of the human body. The results showed that a significantly higher force is generated by the posterior muscles of the amputees during walking, leading to a general increase of the metabolic cost necessary for one step.


Subject(s)
Amputees , Artificial Limbs , Gait , Models, Biological , Muscle Strength , Muscle, Skeletal/physiopathology , Thigh/physiopathology , Female , Femur/pathology , Femur/physiopathology , Humans , Male , Tibia/pathology , Tibia/physiopathology
19.
J Biomech ; 45(1): 199-201, 2012 Jan 03.
Article in English | MEDLINE | ID: mdl-22015239

ABSTRACT

The present study focuses on the determination of human temporal tendons and deep temporal fascia biomechanical behavior. The tensile and shear loads generated by the temporal muscle are transmitted to the masticatory system by the temporal tendons and muscle fascia. Establishing these connective tissues' biomechanical properties will help to develop proper finite element-based simulations of the human masticatory system, which will allow better understanding of diseases affecting the temporomandibular joint. The tissues were harvested from 8 male fresh cadavers, who were subjected to uniaxial tension tests. Available literature states that different connective tissues undergo identical biochemical, cellular and mechanical changes during senescence. Several mechanical phenomena occur during maturation, resulting in stiffer, stronger and more stable connective tissues, although less flexible. Based on this evidence, the present study suggests that older temporal tendon and fascia samples are stiffer than younger ones. We also found significant higher secant moduli with increasing age.


Subject(s)
Aging/physiology , Fascia/physiology , Temporal Muscle/physiology , Tendons/physiology , Adult , Age Factors , Aged , Biomechanical Phenomena/physiology , Cadaver , Finite Element Analysis , Humans , Male , Middle Aged , Shear Strength/physiology , Stress, Mechanical , Temporomandibular Joint/physiology , Tensile Strength/physiology , Young Adult
20.
Comput Methods Biomech Biomed Engin ; 14(4): 365-70, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21442494

ABSTRACT

The present study was conducted in order to establish a methodology based on the finite element method to simulate the contraction of the pelvic floor (PF) muscles. In the generated finite element model, a downward pressure of 90 cm H(2)O was applied, while actively contracting the PF muscles with different degrees of muscular activation (10, 50 and 100%). The finite element methodology of the active contraction behaviour proposed in this study is adequate to simulate PF muscle contraction with different degrees of muscular activation. In this case, in particular, for an activation of 100%, the numerical model was able to displace the pubovisceral muscle in a range of values very similar to the displacement found in the magnetic resonance imaging data. In the analysed case study, it would be possible to conclude that an intensity contraction of 50% would be necessary to produce enough stiffness to avoid possible urine loss.


Subject(s)
Muscle Contraction , Pelvic Floor/physiopathology , Adult , Female , Finite Element Analysis , Humans , Magnetic Resonance Imaging , Models, Biological , Pelvic Floor/anatomy & histology , Urinary Incontinence, Stress/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...