Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 19(15)2019 07 26.
Article in English | MEDLINE | ID: mdl-31357545

ABSTRACT

The goal of this work is to further improve positron emission tomography (PET) attenuation correction and magnetic resonance (MR) sensitivity for head and neck applications of PET/MR. A dedicated 24-channel receive-only array, fully-integrated with a hydraulic system to move a transmission source helically around the patient and radiofrequency (RF) coil array, is designed, implemented, and evaluated. The device enables the calculation of attenuation coefficients from PET measurements at 511 keV including the RF coil and the particular patient. The RF coil design is PET-optimized by minimizing photon attenuation from coil components and housing. The functionality of the presented device is successfully demonstrated by calculating the attenuation map of a water bottle based on PET transmission measurements; results are in excellent agreement with reference values. It is shown that the device itself has marginal influence on the static magnetic field B0 and the radiofrequency transmit field B1 of the 3T PET/MR system. Furthermore, the developed RF array is shown to outperform a standard commercial 16-channel head and neck coil in terms of signal-to-noise ratio (SNR) and parallel imaging performance. In conclusion, the presented hardware enables accurate calculation of attenuation maps for PET/MR systems while improving the SNR of corresponding MR images in a single device without degrading the B0 and B1 homogeneity of the scanner.


Subject(s)
Head/diagnostic imaging , Magnetic Resonance Imaging/methods , Neck/diagnostic imaging , Positron-Emission Tomography/methods , Humans , Image Processing, Computer-Assisted , Multimodal Imaging , Phantoms, Imaging , Radio Waves , Signal-To-Noise Ratio
2.
PLoS One ; 13(11): e0206963, 2018.
Article in English | MEDLINE | ID: mdl-30383832

ABSTRACT

PURPOSE: The purpose of this work is the design, implementation and evaluation of a mechanically flexible receive-only coil array for magnetic resonance imaging (MRI) at 3 T that can be applied to various target organs and provides high parallel imaging performance. METHODS: A 23-channel array was designed based on a rigid-flex printed circuit board (PCB). The flexible multi-layer part contains the copper traces forming the coil elements. The rigid part of the PCB houses the solder joints and lumped elements. The coil housing consists of rigid caps mounted above the rigid parts. Adhesive PTFE sheets cover all flexible parts. The developed array was tested on the bench as well as in phantom and in vivo MRI experiments employing parallel imaging acceleration factors up to six. RESULTS: Efficient mutual decoupling between receive elements and detuning between receive array and body coil was achieved. An increased signal-to-noise ratio in comparison to commercial reference coils is demonstrated, especially in regions close to the developed array and for high parallel imaging acceleration factors. Exemplary in vivo images of head, ankle, knee, shoulder and hand are presented. CONCLUSION: Based on high sensitivity close to the array and low g-factors, this flexible coil is well suited for studies of occipital and temporal cortex, as well as musculoskeletal targets like knee, ankle, elbow and wrist.


Subject(s)
Equipment Design , Magnetic Resonance Imaging , Brain/diagnostic imaging , Humans , Joints/diagnostic imaging , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/standards , Phantoms, Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...