1.
Transl Vis Sci Technol ; 9(13): 31, 2020 12.
Article in English | MEDLINE | ID: mdl-33384885

ABSTRACT

Purpose: To investigate oculomotor behavior in response to dynamic stimuli in retinal implant recipients. Methods: Three suprachoroidal retinal implant recipients performed a four-alternative forced-choice motion discrimination task over six sessions longitudinally. Stimuli were a single white bar ("moving bar") or a series of white bars ("moving grating") sweeping left, right, up, or down across a 42″ monitor. Performance was compared with normal video processing and scrambled video processing (randomized image-to-electrode mapping to disrupt spatiotemporal structure). Eye and head movement was monitored throughout the task. Results: Two subjects had diminished performance with scrambling, suggesting retinotopic discrimination was used in the normal condition and made smooth pursuit eye movements congruent to the moving bar stimulus direction. These two subjects also made stimulus-related eye movements resembling optokinetic reflex (OKR) for moving grating stimuli, but the movement was incongruent with stimulus direction. The third subject was less adept at the task, appeared primarily reliant on head position cues (head movements were congruent to stimulus direction), and did not exhibit retinotopic discrimination and associated eye movements. Conclusions: Our observation of smooth pursuit indicates residual functionality of cortical direction-selective circuits and implies a more naturalistic perception of motion than expected. A distorted OKR implies improper functionality of retinal direction-selective circuits, possibly due to retinal remodeling or the non-selective nature of the electrical stimulation. Translational Relevance: Retinal implant users can make naturalistic eye movements in response to moving stimuli, highlighting the potential for eye tracker feedback to improve perceptual localization and image stabilization in camera-based visual prostheses.


Subject(s)
Visual Prosthesis , Eye Movements , Head Movements , Humans , Photic Stimulation , Pursuit, Smooth
2.
Epilepsy Res ; 135: 29-37, 2017 09.
Article in English | MEDLINE | ID: mdl-28618377

ABSTRACT

OBJECTIVE: Minimally-invasive approaches are needed for long-term reliable Electroencephalography (EEG) recordings to assist with epilepsy diagnosis, investigation and more naturalistic monitoring. This study compared three methods for long-term implantation of sub-scalp EEG electrodes. METHODS: Three types of electrodes (disk, ring, and peg) were fabricated from biocompatible materials and implanted under the scalp in five ambulatory ewes for 3months. Disk electrodes were inserted into sub-pericranial pockets. Ring electrodes were tunneled under the scalp. Peg electrodes were inserted into the skull, close to the dura. EEG was continuously monitored wirelessly. High resolution CT imaging, histopathology, and impedance measurements were used to assess the status of the electrodes at the end of the study. RESULTS: EEG amplitude was larger in the peg compared with the disk and ring electrodes (p<0.05). Similarly, chewing artifacts were lower in the peg electrodes (p<0.05). Electrode impedance increased after long-term implantation particularly for those within the bone (p<0.01). Micro-CT scans indicated that all electrodes stayed within the sub-scalp layers. All pegs remained within the burr holes as implanted with no evidence of extrusion. Eight of 10 disks partially eroded into the bone by 1.0mm from the surface of the skull. The ring arrays remained within the sub-scalp layers close to implantation site. Histology revealed that the electrodes were encapsulated in a thin fibrous tissue adjacent to the pericranium. Overlying this was a loose connective layer and scalp. Erosion into the bone occurred under the rim of the sub-pericranial disk electrodes. CONCLUSIONS: The results indicate that the peg electrodes provided high quality EEG, mechanical stability, and lower chewing artifact. Whereas, ring electrode arrays tunneled under the scalp enable minimal surgical techniques to be used for implantation and removal.


Subject(s)
Electrodes, Implanted , Electroencephalography/instrumentation , Minimally Invasive Surgical Procedures , Animals , Artifacts , Biocompatible Materials , Bone Diseases/etiology , Bone Diseases/pathology , Electric Impedance , Electrodes, Implanted/adverse effects , Electroencephalography/adverse effects , Equipment Design , Female , Mastication , Models, Animal , Scalp/pathology , Scalp/surgery , Sheep, Domestic , Skull/diagnostic imaging , Skull/pathology , Skull/physiopathology , Skull/surgery , Wireless Technology , X-Ray Microtomography
3.
Biosens Bioelectron ; 77: 589-97, 2016 Mar 15.
Article in English | MEDLINE | ID: mdl-26476599

ABSTRACT

A safe, compact and robust means of wireless energy transfer across the skin barrier is a key requirement for implantable electronic devices. One possible approach is photovoltaic (PV) energy delivery using optical illumination at near infrared (NIR) wavelengths, to which the skin is highly transparent. In the work presented here, a subcutaneously implantable silicon PV cell, operated in conjunction with an external NIR laser diode, is developed as a power delivery system. The biocompatibility and long-term biostability of the implantable PV is ensured through the use of an hermetic container, comprising a transparent diamond capsule and platinum wire feedthroughs. A wavelength of 980 nm is identified as the optimum operating point based on the PV cell's external quantum efficiency, the skin's transmission spectrum, and the wavelength dependent safe exposure limit of the skin. In bench-top experiments using an external illumination intensity of 0.7 W/cm(2), a peak output power of 2.7 mW is delivered to the implant with an active PV cell dimension of 1.5 × 1.5 × 0.06 mm(3). This corresponds to a volumetric power output density of ~20 mW/mm(3), significantly higher than power densities achievable using inductively coupled coil-based approaches used in other medical implant systems. This approach paves the way for further ministration of bionic implants.


Subject(s)
Coated Materials, Biocompatible/chemical synthesis , Diamond/chemistry , Electric Power Supplies , Prostheses and Implants , Solar Energy , Energy Transfer , Equipment Design , Equipment Failure Analysis , Materials Testing
4.
Hear Res ; 287(1-2): 30-42, 2012 May.
Article in English | MEDLINE | ID: mdl-22531007

ABSTRACT

A broader activation of auditory nerve fibres than normal using a cochlear implant contributes to poor frequency discrimination. As cochlear implants also deliver a restricted dynamic range, this hinders the ability to segregate sound sources. Better frequency coding and control over amplitude may be achieved by limiting current spread during electrical stimulation of the cochlea and positioning electrodes closer to the modiolus. Thin-film high density microelectrode arrays and conventional platinum ring electrode arrays were used to stimulate the cochlea of urethane-anaesthetized rats and responses compared. Neurophysiological recordings were taken at 197 multi-unit clusters in the central nucleus of the inferior colliculus (CIC), a site that receives direct monaural innervation from the cochlear nucleus. CIC responses to both the platinum ring and high density electrodes were recorded and differences in activity to changes in stimulation intensity, thresholds and frequency coding of neural activation were examined. The high density electrode array elicited less CIC activity at nonspecific frequency regions than the platinum ring electrode array. The high density electrode array produced significantly lower thresholds and larger dynamic ranges than the platinum ring electrode array when positioned close to the modiolus. These results suggest that a higher density of stimulation sites on electrodes that effectively 'aim' current, combined with placement closer to the modiolus would permit finer control over charge delivery. This may equate to improved frequency specific perception and control over amplitude when using future cochlear implant devices.


Subject(s)
Cochlea/innervation , Cochlear Implants , Cochlear Nerve/physiology , Mesencephalon/physiology , Microelectrodes , Animals , Auditory Pathways/physiology , Auditory Threshold , Cochlea/diagnostic imaging , Electric Stimulation , Evoked Potentials, Auditory, Brain Stem , Male , Platinum , Prosthesis Design , Rats , Rats, Wistar , Time Factors , X-Ray Microtomography
5.
Sex Transm Infect ; 83(1): 59-63, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17005542

ABSTRACT

OBJECTIVES: To evaluate the effectiveness of interventions to prevent mother-to-child transmission of HIV at a large teaching hospital in South East London, and to assess reasons for the small numbers of transmissions that continue to occur. DESIGN: A database of all pregnant women diagnosed as HIV positive between 1993 and 2005 was reviewed, with detailed (retrospective) case-note review of all mother-infant pairs where HIV transmission occurred. SETTING: King's College Hospital, London, UK, a teaching hospital serving an ethnically diverse and socially deprived population. RESULTS: 296 pregnancies to 274 women were recorded. 9 of 296 (3.0%) women were lost to follow-up before the end of the pregnancy. Of 287 pregnancies followed up until after delivery, 6 (2.1%) resulted in HIV infection in the infant. More recently, between 2000 and 2004, this transmission rate was even lower, at 3 in 231 (1.3%). Each of these six women had complications, including late presentation to services and defaulting follow-up appointments, which were likely to increase the risk of HIV transmission. Four of the six transmissions occurred in utero. CONCLUSION: The overall transmission rate of 2% attests to the efforts of the multidisciplinary care team in managing this population which is often hard to reach. Clearly, good systems are needed to trace those women who default. Further data are needed regarding in utero transmissions.


Subject(s)
HIV Infections/transmission , HIV-1 , HIV-2 , Pregnancy Complications, Infectious/prevention & control , Adolescent , Adult , Anti-HIV Agents/therapeutic use , Female , HIV Infections/prevention & control , Humans , Infant , Infant, Newborn , Infectious Disease Transmission, Vertical , London , Pregnancy , Prenatal Diagnosis , Retrospective Studies
6.
Clin Exp Ophthalmol ; 28(1): 62-4, 2000 Feb.
Article in English | MEDLINE | ID: mdl-11345350

ABSTRACT

Hypovitaminosis A is a well-recognized condition in many developing countries. However, in the developed world the diagnosis is frequently missed or delayed because of its rarity. A 67-year-old man from metropolitan Adelaide presented to us with gradual but severe bilateral visual loss. He had marked punctate epithelial keratopathy in both eyes. Hypovitaminosis was suspected because of his bizarre dietary habit, and this was confirmed by a combination of impression cytology of the ocular surface and biochemical testing of his venous blood. His vision responded dramatically to vitamin A supplementation. Hypovitaminosis A should be suspected in severe cases of 'dry-eye', especially in those patients with unusual dietary habit or malabsorption.


Subject(s)
Vision Disorders/diagnosis , Vitamin A Deficiency/diagnosis , Xerophthalmia/diagnosis , Aged , Humans , Male , South Australia , Vision Disorders/blood , Vision Disorders/drug therapy , Vitamin A/blood , Vitamin A/therapeutic use , Vitamin A Deficiency/blood , Vitamin A Deficiency/drug therapy , Xerophthalmia/blood , Xerophthalmia/drug therapy