1.
Pacing Clin Electrophysiol ; 21(10): 1893-900, 1998 Oct.
Article in English | MEDLINE | ID: mdl-9793085

ABSTRACT

As the majority of ICDs with transvenous leads are now implanted in the pectoral region, complications associated with the technique are being identified. To determine the incidence of lead complications in patients with transvenous defibrillator leads and ICDs implanted in the pectoral region, 132 unselected consecutive patients with transvenous defibrillator leads had ICDs implanted in the pectoral region. Three lead systems were used: (1) lead system 1 (45 patients) consisted of a transvenous pacing sensing lead and a superior vena cava coil with a submuscular patch used for defibrillation; (2) lead system 2 (36 patients) utilized a CPI Endotak lead system; and (3) lead system 3 (51 patients) utilized a Medtronic Transvene lead system. Patients were followed for 3-54 months (cumulative 2,269, mean 18 months). The average duration of follow-up with the three systems was 32, 12 and 11 months, respectively. At 30 months follow-up, all three lead systems had a low incidence of complications. However, there was a 13% overall incidence (45% actuarial incidence) of erosion of the insulation of the pacing sensing lead of system 1 at 50 months of follow-up. All lead complications were seen in patients with ICDs whose weights were > 195 g and volumes > 115 cc. The erosion was probably a consequence of the pressure by the large ICD against the lead in the pectoral pocket. Follow-up with lead systems 2 and 3 is relatively short (average 12 months) but no lead erosions were seen. Pectoral implantation of ICDs with long transvenous leads and large generators is associated with a moderate risk of late complications in the form of insulation breaks caused by pressure of the generator against the leads. The use of less redundant leads coupled with smaller ICDs will probably eliminate this complication.


Subject(s)
Defibrillators, Implantable , Defibrillators, Implantable/statistics & numerical data , Electrodes, Implanted , Equipment Failure/statistics & numerical data , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Tachycardia, Ventricular/therapy , Time Factors , Ventricular Fibrillation/therapy
2.
Int J Cardiol ; 65(1): 71-4, 1998 Jun 01.
Article in English | MEDLINE | ID: mdl-9699934

ABSTRACT

Preexcitation developed post-operatively in a cardiac transplant recipient whose donor electrocardiogram was normal. An electrophysiology study revealed evidence of a mid-septal atrioventricular (AV) bypass tract. The patient is clinically well fourteen months after transplant and has intermittent preexcitation.


Subject(s)
Arrhythmias, Cardiac/etiology , Heart Conduction System/abnormalities , Heart Transplantation/physiology , Postoperative Complications/etiology , Arrhythmias, Cardiac/physiopathology , Electrocardiography , Female , Humans , Middle Aged
3.
Pacing Clin Electrophysiol ; 20(11): 2864-6, 1997 Nov.
Article in English | MEDLINE | ID: mdl-9392820

ABSTRACT

Analysis of stored electrograms from bipolar far-field electrodes is considered to be useful in differentiating supraventricular from ventricular arrhythmias. A case of inappropriate ICD shocks for sinus tachycardia is presented whereby successive shocks caused marked widening of the ventricular electrograms. Analysis of these stored electrograms, recorded from far-field bipolar electrodes, gave the false impression of ventricular tachycardia. The widening was due to the current of injury effects, probably a consequence of the large amount of intervening myocardium between the bipoles. While analyzing recordings from far-field bipolar electrodes is generally useful, it is not always reliable, for changes in electrogram morphology, relative to baseline rhythm, may result from other factors like current of injury.


Subject(s)
Defibrillators, Implantable , Electrocardiography/methods , Tachycardia, Sinus/diagnosis , Tachycardia, Ventricular/diagnosis , Adult , Defibrillators, Implantable/adverse effects , Diagnosis, Differential , Electronics, Medical , Follow-Up Studies , Humans , Male , Tachycardia, Sinus/physiopathology , Tachycardia, Sinus/therapy