J Am Coll Radiol ; 21(6S): S237-S248, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38823947

ABSTRACT

This document summarizes the relevant literature for the selection of preprocedural imaging in three clinical scenarios in patients needing endovascular treatment or cardioversion of atrial fibrillation. These clinical scenarios include preprocedural imaging prior to radiofrequency ablation; prior to left atrial appendage occlusion; and prior to cardioversion. The appropriateness of imaging modalities as they apply to each clinical scenario is rated as usually appropriate, may be appropriate, and usually not appropriate to assist the selection of the most appropriate imaging modality in the corresponding clinical scenarios. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Atrial Fibrillation , Evidence-Based Medicine , Societies, Medical , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Humans , United States , Preoperative Care/methods , Electric Countershock/methods , Heart Atria/diagnostic imaging , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery
2.
Article in English | MEDLINE | ID: mdl-38703163

ABSTRACT

BACKGROUND: Ventricular tachycardia (VT) recurrence rates remain high following ablation among patients with nonischemic cardiomyopathy (NICM). OBJECTIVES: This study sought to define the prevalence of lipomatous metaplasia (LM) in patients with NICM and VT and its association with postablation VT recurrence. METHODS: From patients who had ablation of left ventricular VT, we retrospectively identified 113 consecutive NICM patients with preprocedural contrast-enhanced cardiac computed tomography (CECT), from which LM was segmented. Nested within this cohort were 62 patients that prospectively underwent CECT and cardiac magnetic resonance from which myocardial border zone and dense late gadolinium enhancement (LGE) were segmented. A control arm of 30 NICM patients without VT with CECT was identified. RESULTS: LM was identified among 57% of control patients without VT vs 83% of patients without VT recurrence and 100% of patients with VT recurrence following ablation. In multivariable analyses, LM extent was the only independent predictor of VT recurrence, with an adjusted HR per 1-g LM increase of 1.1 (P < 0.001). Patients with LM extent ≥2.5 g had 4.9-fold higher hazard of VT recurrence than those with LM <2.5 g (P < 0.001). In the nested cohort with 32 VT recurrences, LM extent was independently associated with VT recurrence after adjustment for border zone and LGE extent (HR per 1 g increase: 1.1; P = 0.036). CONCLUSIONS: Myocardial LM is prevalent in patients with NICM of a variety of etiologies, and its extent is associated with postablation VT recurrence independent of the degree of fibrosis.

5.
medRxiv ; 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38559058

ABSTRACT

Background: Studies of VT mechanisms are largely based on a 2D portrait of reentrant circuits on one surface of the heart. This oversimplifies the 3D circuit that involves the depth of the myocardium. Simultaneous epicardial and endocardial (epi-endo) mapping was shown to facilitate a 3D delineation of VT circuits, which is however difficult via invasive mapping. Objective: This study investigates the capability of noninvasive epicardial-endocardial electrocardiographic imaging (ECGI) to elucidate the 3D construct of VT circuits, emphasizing the differentiation of epicardial, endocardial, and intramural circuits and to determine the proximity of mid-wall exits to the epicardial or endocardial surfaces. Methods: 120-lead ECGs of VT in combination with subject-specific heart-torso geometry are used to compute unipolar electrograms (CEGM) on ventricular epicardium and endocardia. Activation isochrones are constructed, and the percentage of activation within VT cycle length is calculated on each surface. This classifies VT circuits into 2D (surface only), uniform transmural, nonuniform transmural, and mid-myocardial (focal on surfaces). Furthermore, the endocardial breakthrough time was accurately measured using Laplacian eigenmaps, and by correlating the delay time of the epi-endo breakthroughs, the relative distance of a mid-wall exit to the epicardium or the endocardium surfaces was identified. Results: We analyzed 23 simulated and in-vivo VT circuits on post-infarction porcine hearts. In simulated circuits, ECGI classified 21% as 2D and 78% as 3D: 82.6% of these were correctly classified. The relative timing between epicardial and endocardial breakthroughs was correctly captured across all cases. In in-vivo circuits, ECGI classified 25% as 2D and 75% as 3D: in all cases, circuit exits and entrances were consistent with potential critical isthmus delineated from combined LGE-MRI and catheter mapping data. Conclusions: ECGI epi-endo mapping has the potential for fast delineation of 3D VT circuits, which may augment detailed catheter mapping for VT ablation.

7.
Int J Cardiol Cardiovasc Risk Prev ; 21: 200249, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38496328

ABSTRACT

Introduction: Detection of paroxysmal atrial fibrillation (PAF) is crucial for secondary prevention in patients with recent strokes of unknown etiology. This systematic review and meta-analysis assess the predictive power of available risk scores for detecting new PAF after acute ischemic stroke (AIS). Methods: PubMed, Embase, Scopus, and Web of Science databases were searched until September 2023 to identify relevant studies. A bivariate random effects meta-analysis model pooled data on sensitivity, specificity, and area under the curve (AUC) for each score. The QUADAS-2 tool was used for the quality assessment. Results: Eventually, 21 studies with 18 original risk scores were identified. Age, left atrial enlargement, and NIHSS score were the most common predictive factors, respectively. Seven risk scores were meta-analyzed, with iPAB showing the highest pooled sensitivity and AUC (sensitivity: 89.4%, specificity: 74.2%, AUC: 0.83), and HAVOC having the highest pooled specificity (sensitivity: 46.3%, specificity: 82.0%, AUC: 0.82). Altogether, seven risk scores displayed good discriminatory power (AUC ≥0.80) with four of them (HAVOC, iPAB, Fujii, and MVP scores) being externally validated. Conclusion: Available risk scores demonstrate moderate to good predictive accuracy and can help identify patients who would benefit from extended cardiac monitoring after AIS. External validation is essential before widespread clinical adoption.

8.
JACC Clin Electrophysiol ; 10(5): 846-853, 2024 May.
Article in English | MEDLINE | ID: mdl-38551548

ABSTRACT

BACKGROUND: Premature ventricular complexes (PVCs) are common and associated with worse outcomes in patients with heart failure. Class 1C antiarrhythmic drugs (AADs) effectively suppress PVCs, but guidelines currently restrict their use in structural heart disease. OBJECTIVES: This study aimed to assess the safety and efficacy of class 1C AADs in patients with nonischemic cardiomyopathy (NICM) and implantable cardioverter-defibrillators (ICDs). METHODS: All patients with NICM and an ICD treated with flecainide or propafenone at the Hospital of the University of Pennsylvania between 2014 and 2022 were identified. PVC burden, left ventricular ejection fraction (LVEF), and biventricular pacing percentage were compared before and during class 1C AAD treatment. Safety outcomes included sustained atrial and ventricular arrhythmias, heart failure admissions, and death. RESULTS: We identified 34 patients, 23 receiving flecainide and 11 propafenone. Most patients (62%) had failed other AADs or catheter ablation (68%) prior to class 1C AAD initiation. PVC burden decreased from 20% ± 13% to 6% ± 7% (P < 0.001), LVEF increased from 33% ± 9% to 37% ± 10% (P = 0.01), and biventricular pacing percentage increased from 85% ± 9% to 93% ± 7% (P = 0.01). Sustained ventricular tachycardia (2 vs 9 patients) and admissions for decompensated heart failure (2 vs 3 patients) decreased compared with the 12 months prior to class 1C AAD initiation. CONCLUSIONS: Class 1C AADs effectively suppressed PVCs in patients with NICM and ICDs, leading to increases in LVEF and biventricular pacing percentage. In this limited sample, their use was safe. Larger studies are needed to confirm the safety of this approach.


Subject(s)
Anti-Arrhythmia Agents , Cardiomyopathies , Defibrillators, Implantable , Flecainide , Ventricular Premature Complexes , Humans , Male , Female , Anti-Arrhythmia Agents/therapeutic use , Cardiomyopathies/therapy , Cardiomyopathies/complications , Middle Aged , Aged , Flecainide/therapeutic use , Propafenone/therapeutic use , Retrospective Studies , Stroke Volume/physiology , Treatment Outcome
9.
Heart Rhythm O2 ; 5(1): 34-40, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38312199

ABSTRACT

Background: Long-term rhythm monitoring to detect atrial fibrillation (AF) following a cryptogenic stroke (CS) is well established. However, the burden of organized atrial arrhythmias in this population is not well defined. Objective: The purpose of this study was to assess the incidence and risk factors for organized atrial arrhythmias in patients with CS. Methods: We evaluated all patients with CS who received an insertable cardiac monitor (ICM) between October 2014 and April 2020. All ICM transmissions categorized as AF, tachycardia, or bradycardia were reviewed. We evaluated the time to detection of organized AF and the combination of either organized atrial arrhythmia or AF. Results: A total of 195 CS patients with ICMs were included (51% men; mean age 66 ± 12 years; mean CHA2DS2-VASC score 4.6). Over mean follow-up of 18.9 ± 11.2 months, organized atrial arrhythmias lasting ≥30 seconds were detected in 45 patients (23%), of whom 62% did not have AF. Seventeen patients had both organized atrial arrhythmia and AF, and another 21 patients had AF only. Compared to those with normal left atrial size, patients with left atrial enlargement had a higher adjusted risk for development of atrial arrhythmias (mild left atrial enlargement: hazard ratio 1.99; 95% confidence interval 1.06-3.75; moderate/severe left atrial enlargement: hazard ratio 3.06; 95% confidence interval 1.58-5.92). Conclusion: Organized atrial arrhythmias lasting ≥30 seconds are detected in nearly one-fourth of CS patients. Two-thirds of these patients did not have AF. Further studies are required to evaluate the impact of organized atrial arrhythmias on recurrent stroke risk.

10.
Heart Rhythm O2 ; 5(1): 50-59, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38312203

ABSTRACT

Cardiac sarcoidosis (CS) can mimic any cardiomyopathy due to its ability to manifest with a variety of clinical presentations. The exact prevalence of CS remains unknown but has been reported ranging from 2.3% to as high as 29.9% among patients presenting with new onset cardiomyopathy and/or atrioventricular block. Early and accurate diagnosis of CS is often challenging due to the nature of disease progression and lack of diagnostic reference standard. The current diagnostic criteria for CS are lacking in sensitivity and specificity. Here, we review the contemporary role of advanced imaging modalities such as cardiac magnetic resonance imaging and positron emission tomography/computed tomography imaging in diagnosing and prognosticating patients with CS.

11.
Heart Rhythm ; 21(6): 806-811, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38296010

ABSTRACT

BACKGROUND: Targeting non-pulmonary vein triggers (NPVTs) after pulmonary vein isolation may reduce atrial fibrillation (AF) recurrence. Isoproterenol infusion and cardioversion of spontaneous or induced AF can provoke NPVTs but typically require vasopressor support and increased procedural time. OBJECTIVE: The purpose of this study was to identify risk factors for the presence of NPVTs and create a risk score to identify higher-risk subgroups. METHODS: Using the AF ablation registry at the Hospital of the University of Pennsylvania, we included consecutive patients who underwent AF ablation between January 2021 and December 2022. We excluded patients who did not receive NPVT provocation testing after failing to demonstrate spontaneous NPVTs. NPVTs were defined as non-pulmonary vein ectopic beats triggering AF or focal atrial tachycardia. We used risk factors associated with NPVTs with P <.1 in multivariable logistic regression model to create a risk score in a randomly split derivation set (80%) and tested its predictive accuracy in the validation set (20%). RESULTS: In 1530 AF ablations included, NPVTs were observed in 235 (15.4%). In the derivation set, female sex (odds ratio [OR] 1.40; 95% confidence interval [CI] 0.96-2.03; P = .080), sinus node dysfunction (OR 1.67; 95% CI 0.98-2.87; P = .060), previous AF ablation (OR 2.50; 95% CI 1.70-3.65; P <.001), and left atrial scar (OR 2.90; 95% CI 1.94-4.36; P <.001) were risk factors associated with NPVTs. The risk score created from these risk factors (PRE2SSS2 score; [PRE]vious ablation: 2 points, female [S]ex: 1 point, [S]inus node dysfunction: 1 point, left atrial [S]car: 2 points) had good predictive accuracy in the validation cohort (area under the receiver operating characteristic curve 0.728; 95% CI 0.648-0.807). CONCLUSION: A risk score incorporating predictors for NPVTs may allow provocation of triggers to be performed in patients with greatest expected yield.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/etiology , Atrial Fibrillation/diagnosis , Female , Male , Pulmonary Veins/surgery , Middle Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Risk Factors , Risk Assessment/methods , Retrospective Studies , Aged , Registries , Heart Conduction System/physiopathology , Recurrence , Follow-Up Studies
12.
J Cardiovasc Magn Reson ; 26(1): 100995, 2024 Jan 12.
Article in English | MEDLINE | ID: mdl-38219955

ABSTRACT

Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.

13.
J Interv Card Electrophysiol ; 67(3): 559-569, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37592198

ABSTRACT

BACKGROUND: The use of a multi-electrode Optrell mapping catheter during ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation procedures has not been widely reported. OBJECTIVES: We aim to describe the feasibility and safety of using the Optrell multipolar mapping catheter (MPMC) to guide catheter ablation of VT and PVCs. METHODS: We conducted a single-center, retrospective evaluation of patients who underwent VT or PVC ablation between June and November 2022 utilizing the MPMC. RESULTS: A total of 20 patients met the inclusion criteria (13 VT and 7 PVC ablations, 80% male, 61 ± 15 years). High-density mapping was performed in the VT procedures with median 2753 points [IQR 1471-17,024] collected in the endocardium and 12,830 points [IQR 2319-30,010] in the epicardium. Operators noted challenges in manipulation of the MPMC in trabeculated endocardial regions or near valve apparatus. Late potentials (LPs) were detected in 11 cases, 7 of which had evidence of isochronal crowding demonstrated during late annotation mapping. Two patients who also underwent entrainment mapping had critical circuitry confirmed in regions of isochronal crowding. In the PVC group, high-density voltage and activation mapping was performed with a median 1058 points [IQR 534-3582] collected in the endocardium. CONCLUSIONS: This novel MPMC can be used safely and effectively to create high-density maps in LV endocardium or epicardium. Limitations of the catheter include a longer wait time for matrix formation prior to starting point collection and challenges in manipulation in certain regions.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Humans , Male , Female , Retrospective Studies , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Ventricular Premature Complexes/surgery , Electrodes , Catheters , Catheter Ablation/methods
15.
J Interv Card Electrophysiol ; 67(3): 617-623, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37700118

ABSTRACT

BACKGROUND: There is growing interest in the possibility of discontinuing oral anticoagulation following successful catheter ablation of atrial fibrillation (AF). However, it remains unknown whether patients can accurately detect arrhythmia recurrences following ablation. We therefore sought to characterize the accuracy of pulse checking and arrhythmia symptoms for the identification of AF following ablation. METHODS: This prospective cohort study included patients at the Hospital of the University of Pennsylvania with an insertable cardiac monitor (ICM) treated with catheter ablation for AF who recorded the results from minimum twice daily pulse checks and additionally with arrhythmia symptoms into a diary for 2 months following their procedure. Accuracy of this self-assessment protocol was determined by comparison to ICM-detected AF. RESULTS: A total of 55 patients (age 69 ± 8 years, 30 (55%) male, CHA2DS2VASc score 3.2 ± 1. 5) were included. Patients recorded a total of 5911 pulse checks, and there were 280 episodes of ICM-documented AF among 26 patients with an average duration of 2.5 ± 3.3 h. Among 362 episodes of patient-suspected AF, 134 correlated with ICM-identified AF (37% true positive rate). Of the 5549 pulse checks that did not identify AF, 196 correlated with ICM-identified AF (4% false negative rate). Twice daily pulse checking had a sensitivity of 47% and a specificity of 96% for identifying each episode of AF. CONCLUSIONS: Our data indicate that a strategy of pulse checks and symptom assessment is insufficient to identify all episodes of AF in many patients following catheter ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Male , Middle Aged , Aged , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Prospective Studies , Electrocardiography, Ambulatory/methods , Heart Rate , Catheter Ablation/methods
16.
Heart Rhythm ; 21(1): 18-24, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37827346

ABSTRACT

BACKGROUND: Cardiac stereotactic body radiotherapy (SBRT) has emerged as a promising noninvasive treatment for refractory ventricular tachycardia (VT). OBJECTIVE: The purpose of this study was to describe the safety and effectiveness of SBRT for VT in refractory to extensive ablation. METHODS: After maximal medical and ablation therapy, patients were enrolled in a prospective registry. Available electrophysiological and imaging data were integrated to generate a plan target volume. All SBRTs were planned with a single 25 Gy fraction using respiratory motion mitigation strategies. Clinical outcomes at 6 weeks, 6 months, and 12 months were analyzed and compared with the 6 months prior to treatment. VT burden (implantable cardioverter-defibrillator [ICD] shocks and antitachycardia pacing sequences) as well as clinical and safety outcomes were the main outcomes. RESULTS: Fifteen patients were enrolled and underwent planning. Fourteen (93%) underwent treatment, with 12 (80%) surviving to the end of the 6-week period and 10 (67%) surviving to 12 months. From 6 week to 12 months, there was recurrence of VT, which resulted in either appropriate antitachycardia pacing or ICD shocks in 33% (4 of 12). There were significant reductions in treated VT at 6 weeks to 6 months (98%) and at 12 months (99%) compared to the 6 months before treatment. There was a nonsignificant trend toward lower amiodarone dose at 12 months. Four deaths occurred after treatment, with no changes in ventricular function. CONCLUSION: For a select group of high-risk patients with VT refractory to standard therapy, SBRT is associated with a reduction in VT and appropriate ICD therapies over 1 year.


Subject(s)
Amiodarone , Defibrillators, Implantable , Radiosurgery , Tachycardia, Ventricular , Humans , Radiosurgery/methods , Treatment Outcome
18.
Article in English | MEDLINE | ID: mdl-38105353

ABSTRACT

BACKGROUND: Pectoral nerve (PECs) blocks are established regional anesthesia techniques that can provide analgesia to the anterior chest wall. Although commonly performed preoperatively by anesthesiologists, the feasibility of electrophysiologist-performed PECs blocks from within cardiac implantable electronic device (CIED) pockets at the time of implantation has not been established. The objective of this study is to assess the feasibility of routine PECs blocks performed by the electrophysiologist from within the exposed device pocket at the time of CIED procedures. METHODS: Patients undergoing CIED procedures underwent a PECs I block (15 cc of 1% lidocaine/0.25% bupivacaine) injected between the pectoralis major and minor muscles guided by ultrasound placed in the device pocket, or PECs II block, which included a second injection (15 cc) between pectoralis minor and serratus anterior muscles. Postoperatively, pain was assessed on a numeric scale (0-10) at 1, 2, 4, and 24 h, and 2 weeks after the procedure. RESULTS: Among 20 patients (age 65 ± 16 years, 70% male, 55% with history of chronic pain), PECs I (75%) and PECs II (25%) blocks were performed. The procedures were de novo implantation (n = 17) or device revision (n = 3). The average pain score in the first 4 h was 0.4 ± 0.8 and 0.3 ± 0.6 at 24 h after the procedure. During the 24-h postoperative period, 4 patients received opioids. Two patients were discharged with opioids for pain unrelated to the procedure. CONCLUSIONS: Intraoperative PECs blocks can be feasibly performed from within an exposed pocket at the time of CIED procedures with minimal postoperative pain.

19.
JACC Clin Electrophysiol ; 9(12): 2523-2533, 2023 12.
Article in English | MEDLINE | ID: mdl-37715743

ABSTRACT

BACKGROUND: Entrainment and pace mapping are used to identify critical components (CCs) of ventricular tachycardia (VT) circuits. In patients with dense myocardial scarring, VT circuits may elude capture at standard high pacing outputs (up to 10 mA at a 2-millisecond pulse width). OBJECTIVES: The purpose of this study was to assess the utility of very high-output pacing (V-HOP, 50 mA at 2 milliseconds) for identifying CCs of VT circuits after standard high pacing output failed to elicit capture in densely scarred myocardial tissue. METHODS: Our standard VT ablation approach included electroanatomic mapping for substrate characterization and entrainment and/or pace mapping to identify CCs of VT circuits. Patients that required V-HOP to capture sites of interest comprised the study cohort. Ablation endpoints were VT termination and noninducibility. RESULTS: Twenty-five patients (71 ± 10 years of age, all males) undergoing 26 VT ablations met the inclusion criteria. The mean left ventricular ejection fraction was 30% ± 14%, and 85% had ischemic cardiomyopathy. V-HOP was used to successfully entrain VT in 17 patients, yielding central isthmus sites in 10 and entrance/exit sites in 4. VT terminated with radiofrequency ablation at these sites in 15 patients. In 9 patients, V-HOP identified scar locations with a delayed exit. Acute procedural success was achieved in 24 patients without any adverse events. Over a follow-up period of 16 ± 21 months, 2 patients experienced VT recurrence requiring repeat ablation during which the same location was targeted successfully in 1 patient. CONCLUSIONS: In VT patients with a dense scar that is traditionally inexcitable, V-HOP can identify CCs of the re-entrant circuit and guide successful ablation.


Subject(s)
Myocardial Ischemia , Tachycardia, Ventricular , Male , Humans , Cicatrix , Stroke Volume , Ventricular Function, Left , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery
20.
JACC Clin Electrophysiol ; 9(11): 2275-2287, 2023 11.
Article in English | MEDLINE | ID: mdl-37737775

ABSTRACT

BACKGROUND: Targeting nonpulmonary vein triggers (NPVTs) of atrial fibrillation (AF) after pulmonary vein isolation can be challenging. NPVTs are often single ectopic beats with a surface P-wave obscured by a QRS or T-wave. OBJECTIVES: The goal of this study was to construct an algorithm to regionalize the site of origin of NPVTs using only intracardiac bipolar electrograms from 2 linear decapolar catheters positioned in the posterolateral right atrium (along the crista terminalis with the distal bipole pair in the superior vena cava) and in the proximal coronary sinus (CS). METHODS: After pulmonary vein isolation in 42 patients with AF, pacing from 15 typical anatomic NPVT sites was conducted. For each pacing site, the electrogram activation sequence was analyzed from the CS catheter (simultaneous/chevron/inverse chevron/distal-proximal/proximal-distal) and activation time (ie, CSCTAT) between the earliest electrograms from the 2 decapolar catheters was measured referencing the earliest CS electrogram; a negative CSCTAT value indicates the crista terminalis catheter electrogram was earlier, and a positive CSCTAT value indicates the CS catheter electrogram was earlier. A regionalization algorithm with high predictive value was defined and tested in a validation cohort with AF NPVTs localized with electroanatomic mapping. RESULTS: In the study patient cohort (71% male; 43% with persistent AF, 52% with left atrial dilation), the algorithm grouped with high precision (positive predictive value 81%-99%, specificity 94%-100%, and sensitivity 30%-94%) the 15 distinct pacing sites into 9 clinically useful regions. Algorithm testing in a 98 patient validation cohort showed predictive accuracy of 91%. CONCLUSIONS: An algorithm defined by the activation sequence and timing of electrograms from 2 linear multipolar catheters provided accurate regionalization of AF NPVTs to guide focused detailed mapping.


Subject(s)
Atrial Fibrillation , Vena Cava, Superior , Humans , Male , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Atria , Catheters , Algorithms