Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Cardiol ; 207: 28-34, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37722198

ABSTRACT

Transcatheter aortic valve replacement (TAVR) generates significant debris, and strategies to mitigate cerebral embolization are needed. The novel Emboliner embolic protection catheter (Emboline, Inc., Santa Cruz, California) is designed to capture all particles generated during TAVR. This first-in-human study sought to assess the safety and feasibility of the device and to characterize the distribution and histopathology of the debris generated during TAVR. The SafePass 2 study was a prospective, nonrandomized, multicenter, single-arm investigation of the Emboliner device. Primary end points included 30-day major adverse cardiac and cerebrovascular events (MACCE) and technical performance. Computed tomography angiography was analyzed by an independent core laboratory, and filters were sent for histopathology of captured debris. Predictors of particle number were identified using >150 µm and >500 µm size thresholds. Of 31 subjects enrolled, technical success was 100%, and 30-day MACCE was 6.5% (2 cerebrovascular accidents, with 1 attributed to subtherapeutic dosing of rivaroxaban along with atrial fibrillation and the other to possible previous small ischemic strokes on magnetic resonance imaging; neither MACCE event had a causal relation to the Emboliner). All filters contained debris, with a median of 191.0 particles >150 µm and 14.0 particles >500 µm. Histopathology revealed mostly acute thrombus and valve or arterial tissue with lesser amounts of calcified tissue. A history of atrial fibrillation predicted a greater number of particles >500 µm (p = 0.0259) and its presence on admission was associated with 4.1 times more particles >150 µm (p = 0.0130) and 8.1 times more particles >500 µm (p = 0.0086). Self-expanding valves were associated with twice the number of particles >150 µm (p = 0.0281). TASK score was positively correlated with number of particles >500 µm (p = 0.0337). The Emboliner device was safe and feasible. Emboli after TAVR appear more numerous than previously documented. Atrial fibrillation, higher TASK score, and self-expanding valve use conferred higher embolic burden. Notably, none of the tested computed tomography angiography features were able to identify with higher embolic risk. Larger-scale studies are needed to identify high-risk patients for selective embolic protection device use.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Embolic Protection Devices , Embolism , Intracranial Embolism , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/pathology , Aortic Valve Stenosis/complications , Prospective Studies , Atrial Fibrillation/complications , Risk Factors , Treatment Outcome , Embolism/epidemiology , Embolism/etiology , Intracranial Embolism/epidemiology , Intracranial Embolism/etiology , Intracranial Embolism/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...