Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Eng Technol ; 14(2): 182-193, 2023 04.
Article in English | MEDLINE | ID: mdl-36357649

ABSTRACT

PURPOSE: Leaflet thrombosis is a potentially fatal complication after transcatheter aortic valve replacement (TAVR). Blood flow stagnation in the neo-sinus and aortic sinuses are associated with increased thrombus severity. Native aortic leaflet modification may be a potential strategy to improve the neo-sinus and aortic sinus fluid dynamics. However, limited data exist on the effect of leaflet geometry modification on the flow within the neo-sinus and aortic sinus regions. We evaluate the effect of aortic leaflet modification on the neo-sinus and aortic sinus flow stagnation after simulated TAVR. METHODS: Particle image velocimetry measurements were performed under nominal (5 LPM) and low (2.5 LPM) cardiac output conditions for an intact leaflet (control) case, and 3 modified leaflet geometries. Aortic leaflet geometry modification via leaflet splay was simulated with increasing splay geometry (leaflet splay distance: 5 mm-narrow, 10 mm-medium, and 20 mm-wide). RESULTS: Leaflet geometry modification influenced flow features throughout the cardiac cycle, at both cardiac outputs, and allowed for flow communication between the neo-sinus and aortic sinus regions compared to the control. In the aortic sinus, flow stagnation reduced by over 64% at 5LPM, and over 36% at 2.5LPM for all simulated modified leaflet geometries compared to the control. However, only the medium and wide splay geometries enabled a reduction in neo-sinus flow stagnation compared to the control case. CONCLUSIONS: These findings suggest that aortic leaflet geometry modification (of at least 10 mm leaflet splay distance) may reduce flow stasis and potentially decrease valve thrombosis risk.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Sinus of Valsalva , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Sinus of Valsalva/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Thrombosis/etiology , Prosthesis Design
2.
J Thorac Cardiovasc Surg ; 159(5): 1766-1774.e2, 2020 05.
Article in English | MEDLINE | ID: mdl-31272749

ABSTRACT

OBJECTIVE: The study objective was to develop a novel annuloplasty ring with regional flexibility and assess its suture force dynamics in healthy ovine subjects compared with fully rigid or fully flexible rings. METHODS: Materially heterogeneous rings were created with rigid anterior and posterior, and flexible commissural segments. These rings were created to match the geometry of the Profile 3D ring (Medtronic, Minneapolis, Minn). Each ring was instrumented with 10 force transducers to measure cyclic suture forces (FC) and undersized annuloplasty was performed in 6 healthy ovine subjects. Each FC was recorded and examined for cardiac cycles reaching a maximum left ventricular pressure of 100, 125, and 150 mm Hg. FC was compared with previously reported values from fully rigid Profile 3D and fully flexible prototype rings. RESULTS: Relative to the fully rigid ring, the heterogeneous ring exhibited 48% reduction in FC at its commissural (rigid vs heterogeneous: 1.80 ± 0.94 N vs 0.95 ± 0.52 N; P < .001) and 32% reduction in posterior (1.90 ± 0.92 N vs 1.29 ± 0.91 N; P < .001) regions, but not in its anterior region (2.45 ± 1.21 N vs 2.23 ± 1.22 N; P = .279). Relative to the fully flexible ring, the heterogeneous ring exhibited no significant differences in FC in any region. CONCLUSIONS: The reduced FC of the heterogeneous ring relative to the fully rigid ring suggests a promising approach to reduce suture loading while preserving the annular remodeling capability of fully rigid rings. Future studies in diseased subjects are necessary to explore repair effectiveness of this ring.


Subject(s)
Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve/surgery , Prosthesis Design , Animals , Heart Valve Prosthesis Implantation/adverse effects , Materials Testing , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Annuloplasty/adverse effects , Models, Animal , Pliability , Sheep, Domestic , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...