Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Electrophysiol ; 31(6): 1270-1276, 2020 06.
Article in English | MEDLINE | ID: mdl-32219901

ABSTRACT

BACKGROUND: Outcomes of catheter ablation for persistent atrial fibrillation (PeAF) are suboptimal. The convergent procedure (CP) may offer improved efficacy by combining endocardial and epicardial ablation. METHODS: We reviewed 113 consecutive patients undergoing the CP at our institution. The cohort was divided into two groups based on the presence (n = 92) or absence (n = 21) of continuous rhythm monitoring (CM) following the CP. Outcomes were reported in two ways. First, using a conventional definition of any atrial fibrillation/atrial tachycardia (AF/AT) recurrence lasting >30 seconds, after a 90 day blanking period. Second, by determining AF/AT burden at relevant time points in the group with CM. RESULTS: Across the entire cohort, 88% had either persistent or long-standing persistent AF, mean duration of AF diagnosis before the CP was 5.1 ± 4.6 years, 45% had undergone at least one prior AF ablation, 31% had impaired left ventricle ejection fraction and 62% met criteria for moderate or severe left atrial enlargement. Mean duration of follow-up after the CP was 501 ± 355 days. In the entire cohort, survival free from any AF/AT episode >30 seconds at 12 months after the blanking period was 53%. However, among those in the CM group who experienced recurrences, mean burden of AF/AT was generally very low (<5%) and remained stable over the duration of follow-up. Ten patients (9%) required elective cardioversion outside the 90 day blanking period, 11 patients (9.7%) underwent repeat ablation at a mean of 229 ± 178 days post-CP and 64% were off AADs at the last follow-up. Procedural complications decreased significantly following the transition from transdiaphragmatic to sub-xiphoid surgical access: 23% versus 3.8% (P = .005) CONCLUSIONS: In a large, consecutive series of patients with predominantly PeAF, the CP was capable of reducing AF burden to very low levels (generally <5%), which appeared durable over time. Complication rates associated with the CP decreased significantly with the transition from transdiaphragmatic to sub-xiphoid surgical access. Future trials will be necessary to determine which patients are most likely to benefit from the convergent approach.


Subject(s)
Ablation Techniques , Atrial Fibrillation/surgery , Electrocardiography, Ambulatory , Heart Conduction System/surgery , Telemetry , Ablation Techniques/adverse effects , Action Potentials , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation , Cryosurgery , Disease-Free Survival , Electrocardiography, Ambulatory/instrumentation , Female , Heart Conduction System/physiopathology , Heart Rate , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Recurrence , Reoperation , Telemetry/instrumentation , Time Factors
2.
Ann Thorac Surg ; 104(6): 1939-1946, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28942076

ABSTRACT

BACKGROUND: The effect of frailty on outcomes after transcatheter aortic valve replacement (TAVR) remains incompletely understood. The objective of this study was to evaluate the performance of four commonly used frailty markers as predictors of early and late outcomes among patients undergoing TAVR. METHODS: A review was performed of 361 high- and extreme-risk patients undergoing TAVR from 2011 to 2015. Four frailty variables were assessed: serum albumin (g/dL), 5-m walk (seconds), grip strength (kg), and Katz index of independence in activities of daily living. Logistic regression was used to examine the association between the frailty indicators and 30-day composite of mortality, stroke, new heart block requiring permanent pacemaker, major or life-threatening bleeding, acute renal failure, major vascular complication, and 30-day readmission rate. Minimum distance to the perfect point (0, 1) was performed to delineate a cutoff point for each frailty indicator, and risk models were compared using receiver-operating characteristics curves. RESULTS: The composite of outcomes occurred in 28% of patients. Serum albumin, activities of daily living, and 5-m walk were independent predictors for 30-day composite outcomes, but only albumin was predictive of 30-day mortality. A new frailty model (four frailty indicators, age, and sex) to predict 30-day mortality was created and compared with The Society of Thoracic Surgeons predicted risk of mortality. Better discrimination was found with the new frailty model (area under the curve 0.74 versus 0.58). New individual frailty variable cutoff values were found to predict our composite of events. CONCLUSIONS: Among high- and extreme-risk patients undergoing TAVR, our new frailty model was more discriminative of 30-day mortality than The Society of Thoracic Surgeons predicted risk of mortality. New cutoff values for frailty indicators were identified and will require further validation.


Subject(s)
Aortic Valve Stenosis/surgery , Frailty , Patient Selection , Transcatheter Aortic Valve Replacement , Activities of Daily Living , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Exercise Tolerance , Female , Hand Strength , Humans , Logistic Models , Male , Retrospective Studies , Risk Assessment , Serum Albumin/metabolism , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...