Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Bioanal Chem ; 415(27): 6757-6769, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37740752

ABSTRACT

Over the last decade, applications of ion mobility-mass spectrometry (IM-MS) have exploded due primarily to the widespread commercialization of robust instrumentation from several vendors. Unfortunately, the modest resolving power of many of these platforms (~40-60) has precluded routine separation of constitutional and stereochemical isomers. While instrumentation advances have pushed resolving power to >150 in some cases, chemical approaches offer an alternative for increasing resolution with existing IM-MS instrumentation. Herein we explore the utility of two reactions, derivatization by Girard's reagents and 1,1-carbonyldiimidazole (CDI), for improving IM separation of steroid hormone isomers. These reactions are fast (≤30 min), simple (requiring only basic lab equipment/expertise), and low-cost. Notably, these reactions are structurally selective in that they target carbonyl and hydroxyl groups, respectively, which are found in all naturally occurring steroids. Many steroid hormone isomers differ only in the number, location, and/or stereochemistry of these functional groups, allowing these reactions to "amplify" subtle structural differences and improve IM resolution. Our results show that resolution was significantly improved amongst CDI-derivatized isomer groups of hydroxyprogesterone (two-peak resolution of Rpp = 1.10 between 21-OHP and 11B-OHP), deoxycortisone (Rpp = 1.47 between 11-DHC and 21-DOC), and desoximetasone (Rpp = 1.98 between desoximetasone and fluocortolone). Moreover, characteristic collision cross section (DTCCSN2) measurements can be used to increase confidence in the identification of these compounds in complex biological mixtures. To demonstrate the feasibility of analyzing the derivatized steroids in complex biological matrixes, the reactions were performed following steroid extraction from urine and yielded similar results. Additionally, we applied a software-based approach (high-resolution demultiplexing) that further improved the resolving power (>150). Overall, our results suggest that targeted derivatization reactions coupled with IM-MS can significantly improve the resolution of challenging isomer groups, allowing for more accurate and efficient analysis of complex mixtures.

2.
J Am Soc Mass Spectrom ; 33(9): 1761-1771, 2022 Sep 07.
Article in English | MEDLINE | ID: mdl-35914213

ABSTRACT

Steroids are an important class of biomolecules studied for their role in metabolism, development, nutrition, and disease. Although highly sensitive GC- and LC-MS/MS-based methods have been developed for targeted quantitation of known steroid metabolites, emerging techniques including ion mobility (IM) have shown promise in improved analysis and capacity to better identify unknowns in complex biological samples. Herein, we couple LC-IM-MS/MS with structurally selective reactions targeting hydroxyl and carbonyl functional groups to improve IM resolution and structural elucidation. We demonstrate that 1,1-carbonyldiimidazole derivatization of hydroxyl stereoisomer pairs such as testosterone/epitestosterone and androsterone/epiandrosterone results in increased IM resolution with ΔCCS > 15%. Additionally, performing this in parallel with derivatization of the carbonyl group by Girard's Reagent P resulted in unique products based on relative differences in number of each functional group and C17 alkylation. These changes could be easily deciphered using the combination of retention time, collision cross section, accurate mass, and MS/MS fragmentation pattern. Derivatization by Girard's Reagent P, which contains a fixed charge quaternary amine, also increased the ionization efficiency and could be explored for its potential benefit to sensitivity. Overall, the combination of these simple and easy derivatization reactions with LC-IM-MS/MS analysis provides a method for improved analysis of known target analytes while also yielding critical structural information that can be used for identification of potential unknowns.


Subject(s)
Steroids , Tandem Mass Spectrometry , Amines/analysis , Chromatography, Liquid/methods , Indicators and Reagents , Steroids/analysis , Tandem Mass Spectrometry/methods
3.
J Mass Spectrom Adv Clin Lab ; 24: 50-56, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35469203

ABSTRACT

Introduction: Ion mobility-mass spectrometry (IM-MS) is an emerging technique in the -omics fields that has broad potential applicability to the clinical lab. As a rapid, gas-phase structure-based separation technique, IM-MS offers promise in isomer separations and can be easily combined with existing LC-MS methods (i.e., LC-IM-MS). Several experimental conditions, including analyte cation adducts and drift composition further provide a means to tune separations for global and/or targeted applications. Objectives: The primary objective of this study was to demonstrate the utility of IM-MS under a range of experimental conditions for detection of glucocorticoids, and specifically for the separation of several isomeric pairs. Methods: LC-IM-MS was used to characterize 16 glucocorticoids including three isomer pairs: cortisone/prednisolone, betamethasone/dexamethasone, and flunisolide/triamcinolone acetonide. Collision cross section (CCS) values were measured for all common adducts (e.g., protonated and sodiated) using both step-field and single-field methods. Alternative alkali, alkaline earth, and transition metals were introduced, such that their adducts could also be measured. Finally, four different drift gases (helium, nitrogen, argon, and carbon dioxide) were compared for their relative separation capability. Results: LC-IM-MS offered a robust, multidimensional separation technique that allowed for the 16 glucocorticoids to be analyzed and separated in three-dimensions (retention time, CCS, and m/z). Despite the relatively modest resolution of isomer pairs under standard conditions (i.e., nitrogen drift gas, sodiated ions, etc.), improvements were observed for alkaline earth and transition metals (notable barium adducts) and in carbon dioxide drift gas. Conclusion: In summary, LC-IM-MS offers potential as a clinical method due to its ease of coupling with traditional LC-MS methods and its promise for tuning separations to better resolve targeted and/or global isomers in complex biological samples.

4.
J Am Soc Mass Spectrom ; 33(1): 54-61, 2022 Jan 05.
Article in English | MEDLINE | ID: mdl-34936363

ABSTRACT

Anabolic androgenic steroids (AAS) make up one of the most prevalent classes of performance-enhancing drugs banned by the World Anti-Doping Agency (WADA) due to the competitive advantage they can afford athletes. Mass spectrometry-based methods coupled with chromatographic separations have become the gold standard for AAS analysis because of the superior sensitivity and selectivity provided. However, emerging analytical techniques including ion mobility spectrometry (IMS) have been demonstrated in recent applications as a means to further characterize and identify potential unknowns while simultaneously delivering improved sensitivity by filtering noise. Herein we outline the next crucial steps in bringing IMS to the routine drug testing workflow by combining it with established chromatographic and mass spectrometry methods (i.e., LC-IM-MS) for the detection of AAS in human urine. In addition to robust measurement of collision cross sections which can be used for identification purposes, functional group microtrends provide a structural basis on which to elucidate the structure of future novel anabolic agents. Lastly, the developed workflow is tested by analysis of testosterone in a realistic matrix (human urine) and demonstrates a limit of detection of 524 pg/mL, which surpasses the WADA Minimum Required Performance Levels for anabolic steroids. This work is expected to pave the way toward routine incorporation of IMS into analytical drug testing workflows to augment both qualitative and quantitative measure of performance enhancing drugs in the future.

SELECTION OF CITATIONS
SEARCH DETAIL
...