Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Respiration ; 102(11): 948-960, 2023.
Article in English | MEDLINE | ID: mdl-37906995

ABSTRACT

Patients living with chronic bronchitis (CB) suffer from physical limitations and poor quality of life. In general, treatment options that directly address the mucus hypersecretion component of CB are quite limited. Chronic airway inflammation and the associated hypersecretion and cough that are pathognomonic for CB generally result from long-term exposure to airway irritants such as tobacco use and other environmental insults. This, in turn, results in an increase in the quantity and change in composition of the airway mucosa as a consequence of altered goblet cells, club cells, and submucosal glands. Pulsed electric fields (PEFs) provide a method for eradicating the cellular constituents of tissue with limited impact on the stromal proteins. Preclinical evidence in porcine airways demonstrated that particular PEF waveforms allowed for salutary remodeling of the epithelial and submucosal airway tissue layers and appeared to foster rapid regeneration and recovery of the tissue. Therefore, a therapeutic opportunity might exist whereby the application of a specific form of PEF may result in a reduction of the cellular secretory constituents of the airway while also reducing airway mucosal inflammation. This review discusses the use of such PEF to address the underlying disease processes in CB including challenges around device design, dosing, and appropriate delivery methods. Further, we outline considerations for the transition to human airways along with a brief examination of the initial work treating CB patients, suggesting that the therapy is well tolerated with limited adverse events.


Subject(s)
Bronchitis, Chronic , Humans , Animals , Swine , Bronchitis, Chronic/therapy , Bronchitis, Chronic/metabolism , Quality of Life , Mucus/metabolism , Goblet Cells/metabolism , Inflammation/metabolism , Mucous Membrane/metabolism
2.
Int J Hyperthermia ; 36(1): 953-963, 2019.
Article in English | MEDLINE | ID: mdl-31542973

ABSTRACT

Purpose: This study evaluates the effects of various pulsing paradigms, on the irreversible electroporation (IRE) lesion, induced electric current, and temperature changes using a perfused porcine liver model. Materials and methods: A 4-monopolar electrode array delivered IRE therapy varying the pulse length and inter-pulse delay to six porcine mechanically perfused livers. Pulse paradigms included six forms of cycled pulsing schemes and the conventional pulsing scheme. Finite element models provided further insight into the effects of cycled pulsing on the temperature and thermal injury distribution. Results: 'Single pulse cycle with no interpulse delay' deposited maximum average energy (2.34 ± 0.35 kJ) and produced the largest ratio of thermally damaged tissue area and IRE ablation area from all other pulse schemes (18.22% ± 8.11, p < .0001 all pairwise comparisons). These compared favorably to the conventional algorithm (2.09 ± 0.37 kJ, 3.49% ± 2.20, p < .0001, all comparisons). Though no statistical significance was found between groups, the '5 pulse cycle, 0 s delay' pulse paradigm produced the largest average IRE ablation cross sectional area (11.81 ± 1.97 cm2), while conventional paradigm yielded an average of 8.90 ± 0.91 cm2. Finite element modeling indicated a '10 pulse cycle, 10 s delay' generated the least thermal tissue damage and '1 pulse cycle, 0 s delay' pulse cycle sequence the most (0.47 vs. 3.76 cm2), over a lengthier treatment time (16.5 vs. 6.67 minutes). Conclusions: Subdividing IRE pulses and adding delays throughout the treatment can reduce white tissue coagulation and electric current, while maintaining IRE treatment sizes.


Subject(s)
Electroporation/methods , Animals , Electrodes , Swine , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...