Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Surg ; 109(4): 372-380, 2022 03 15.
Article in English | MEDLINE | ID: mdl-35170730

ABSTRACT

BACKGROUND: Retransplantation candidates are disadvantaged owing to lack of good-quality liver grafts. Strategies that can facilitate transplantation of suboptimal grafts into retransplant candidates require investigation. The aim was to determine whether late liver retransplantation can be performed safely with suboptimal grafts, following normothermic machine perfusion. METHODS: A prospectively enrolled group of patients who required liver retransplantation received a suboptimal graft preserved via normothermic machine perfusion. This group was compared with both historical and contemporaneous cohorts of patient who received grafts preserved by cold storage. The primary outcome was 6-month graft and patient survival. RESULTS: The normothermic machine perfusion group comprised 26 patients. The historical (cold storage 1) and contemporaneous (cold storage 2) groups comprised 31 and 25 patients respectively. The 6-month graft survival rate did not differ between groups (cold storage 1, 27 of 31, cold storage 2, 22 of 25; normothermic machine perfusion, 22 of 26; P = 0.934). This was despite the normothermic machine perfusion group having significantly more steatotic grafts (8 of 31, 7 of 25, and 14 of 26 respectively; P = 0.006) and grafts previously declined by at least one other transplant centre (5 of 31, 9 of 25, and 21 of 26; P < 0.001). CONCLUSION: In liver retransplantation, normothermic machine perfusion can safely expand graft options without compromising short-term outcomes.


Liver transplantation is a life-saving procedure for many different diseases. In the UK, one in 10 patients awaiting transplant have had a previous liver transplant. These retransplant operations are complex, and the general belief is that a good-quality donor liver graft is required for best outcomes. However, there is a significant shortage of good-quality organs for liver transplantation, so many patients awaiting retransplantation spend longer on the waiting list. This study investigated whether a new technology, called normothermic machine perfusion, could be used to preserve lower-quality donor livers and have successful outcomes for patients undergoing retransplantation. Traditionally, good-quality livers are preserved in an ice box and the study compared the outcomes of these two different approaches. The aim was to prove that normothermic machine perfusion improves access to transplantation for this group of patients, without compromising outcomes. A group of patients who underwent retransplantation and received a lesser-quality liver preserved with normothermic machine perfusion was compared with two groups of patients who had received a transplant with traditional ice-box preservation. The complications, graft, and patient survival of the former group was compared with those in the latter two groups who underwent liver retransplantation with better-quality liver grafts. The rate of survival and adverse surgical outcomes were comparable between the groups of patients who received a liver preserved via traditional ice-box preservation, and those who received a lesser-quality liver preserved via normothermic machine perfusion. Normothermic machine perfusion can potentially expand the number of suitable donor livers available for retransplant candidates.


Subject(s)
Liver Transplantation , Graft Survival , Humans , Liver , Organ Preservation , Perfusion
2.
Langenbecks Arch Surg ; 407(2): 717-726, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34999966

ABSTRACT

BACKGROUND: Ex vivo normothermic machine liver perfusion (NMLP) involves artificial cannulation of vessels and generation of flow pressures. This could lead to shear stress-induced endothelial damage, predisposing to vascular complications, or improved preservation of donor artery quality. This study aims to assess the spatial donor hepatic artery (HA) endothelial quality downstream of the cannulation site after end-ischaemic NMLP. METHODS: Remnant HA segments from the coeliac trunk up to the gastroduodenal artery branching were obtained after NMLP (n = 15) and after static cold storage (SCS) preservation (n = 15). Specimens were fixed in 10% neutral buffered formalin and sectioned at pre-determined anatomical sites downstream of the coeliac trunk. CD31 immunohistostaining was used to assess endothelial integrity by a 5-point ordinal scale (grade 0: intact endothelial lining, grade 5: complete denudation). Endothelial integrity after SCS was used as a control for the state of the endothelium at commencement of NMP. RESULTS: In the SCS specimens, regardless of the anatomical site, near complete endothelial denudation was present throughout the HA (median scores 4.5-5). After NMLP, significantly less endothelial loss in the distal HA was present compared to SCS grafts (NMLP vs. SCS: median grade 3 vs. 4.5; p = 0.042). In NMLP specimens, near complete endothelial denudation was present at the cannulation site in all cases (median grade: 5), with significantly less loss of the endothelial lining the further from the cannulation site (proximal vs. distal, median grade 5 vs. 3; p = 0.005). CONCLUSION: Loss of endothelial lining throughout the HA after SCS and at the cannulation site after NMLP suggests extensive damage related to surgical handling and preservation injury. Gradual improved endothelial lining along more distal sites of the HA after NMLP indicates potential for re-endothelialisation. The regenerative effect of NMLP on artery quality seems to occur to a greater extent further from the cannulation site. Therefore, arterial cannulation for machine perfusion of liver grafts should ideally be as proximal as possible on the coeliac trunk or aortic patch, while the site of anastomosis should preferentially be attempted distal on the common HA.


Subject(s)
Hepatic Artery , Organ Preservation , Endothelium , Humans , Liver/surgery , Perfusion
3.
Am J Transplant ; 19(1): 21-31, 2019 01.
Article in English | MEDLINE | ID: mdl-29956477

ABSTRACT

The Lung session of the 2017 14th Banff Foundation for Allograft Pathology Conference, Barcelona focused on the multiple aspects of antibody-mediated rejection (AMR) in lung transplantation. Multidimensional approaches for AMR diagnosis, including classification, histological and immunohistochemical analysis, and donor- specific antibody (DSA) characterization with their current strengths and limitations were reviewed in view of recent research. The group also discussed the role of tissue gene expression analysis in the context of unmet needs in lung transplantation. The current best practice for monitoring of AMR and the therapeutic approach are summarized and highlighted in this report. The working group reached consensus of the major gaps in current knowledge and focused on the unanswered questions regarding pulmonary AMR. An important outcome of the meeting was agreement on the need for future collaborative research projects to address these gaps in the field of lung transplantation.


Subject(s)
Antibodies/immunology , Graft Rejection/immunology , Lung Transplantation , Lung/immunology , Allografts , Complement C4/immunology , Gene Expression Profiling , HLA Antigens/immunology , Humans , Immunohistochemistry , Isoantibodies/immunology , Peptide Fragments/immunology , Societies, Medical , Tissue Donors , Transplantation, Homologous
4.
Am J Transplant ; 16(11): 3235-3245, 2016 11.
Article in English | MEDLINE | ID: mdl-27192971

ABSTRACT

The demand for liver transplantation (LT) exceeds supply, with rising waiting list mortality. Utilization of high-risk organs is low and a substantial number of procured livers are discarded. We report the first series of five transplants with rejected livers following viability assessment by normothermic machine perfusion of the liver (NMP-L). The evaluation protocol consisted of perfusate lactate, bile production, vascular flows, and liver appearance. All livers were exposed to a variable period of static cold storage prior to commencing NMP-L. Four organs were recovered from donors after circulatory death and rejected due to prolonged donor warm ischemic times; one liver from a brain-death donor was declined for high liver function tests (LFTs). The median (range) total graft preservation time was 798 (range 724-951) min. The transplant procedure was uneventful in every recipient, with immediate function in all grafts. The median in-hospital stay was 10 (range 6-14) days. At present, all recipients are well, with normalized LFTs at median follow-up of 7 (range 6-19) months. Viability assessment of high-risk grafts using NMP-L provides specific information on liver function and can permit their transplantation while minimizing the recipient risk of primary graft nonfunction. This novel approach may increase organ availability for LT.


Subject(s)
Liver Transplantation , Liver/metabolism , Organ Preservation , Perfusion/methods , Tissue Donors/supply & distribution , Tissue Survival , Tissue and Organ Procurement/methods , Adult , Aged , Allografts , Female , Follow-Up Studies , Graft Rejection/prevention & control , Humans , Liver/blood supply , Liver Function Tests , Male , Middle Aged , Outcome Assessment, Health Care , Pilot Projects , Primary Graft Dysfunction/prevention & control , Warm Ischemia
6.
Scand J Gastroenterol ; 48(12): 1444-51, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24131305

ABSTRACT

INTRODUCTION. The impact of preformed donor-specific antibodies (DSA) is incompletely understood in liver transplantation. The incidence and impact of preformed DSA on early post liver transplant were assessed and these were correlated with compliment fragment C4d on allograft biopsy. METHODS. Pretransplant serum from 41 consecutive liver transplant recipients (brain dead donors; DBD = 27 and cardiac death donors; DCD = 14) were tested for class-specific anti-human leukocyte antigen (HLA) and compared against donor HLA types. Liver biopsies were taken during cold storage (t-1) and post-reperfusion (t0) stained with C4d and graded for preservation-reperfusion injury (PRI). RESULTS. Of the 41 recipients, 8 (20%) had anti-HLA class I/II antibodies pretransplant, 3 (7%) were confirmed preformed DSA; classes I and II (n=1) and class I only (n=2). No biopsies showed definite evidence of antibody-mediated rejection. Graft biopsies in overall showed only mild PRI with ischemic hepatocyte C4d pattern similar in both positive and negative DSA patients. One DSA-positive (33%) compared with four DSA-negative patients (10%) had significant early graft dysfunction; severe PRI causing graft loss from primary nonfunction was seen only in DSA-negative group. Allograft biopsy of preformed DSA-positive patient demonstrated only minimal PRI; however, no identifiable cause could be attributed to graft dysfunction other than preformed DSA. CONCLUSION. Preformed DSA are present in 5-10% liver transplant recipients. There is no association between anti-HLA DSA and PRI and C4d, but preformed DSA may cause early morbidity. Larger studies on the impact of DSA with optimization of C4d techniques are required.


Subject(s)
Allografts/immunology , Complement C4b/metabolism , HLA Antigens/immunology , Isoantibodies/blood , Liver Transplantation , Liver/immunology , Peptide Fragments/metabolism , Primary Graft Dysfunction/immunology , Aged , Allografts/metabolism , Allografts/pathology , Allografts/physiopathology , Biomarkers/metabolism , Biopsy , Female , Graft Rejection/immunology , Humans , Liver/metabolism , Liver/pathology , Liver/physiopathology , Male , Middle Aged , Outcome Assessment, Health Care , Primary Graft Dysfunction/metabolism , Retrospective Studies , Transplantation, Homologous
SELECTION OF CITATIONS
SEARCH DETAIL
...