Phys Rev Lett ; 112(16): 164802, 2014 Apr 25.
Article in English | MEDLINE | ID: mdl-24815654

ABSTRACT

Static magnetic undulators used by x-ray light sources are fundamentally too limited to achieve shorter undulator periods and dynamic control. To overcome these limitations, we report experimental demonstration of a novel short-period microwave undulator, essentially a Thomson scattering device, that has yielded tunable spontaneous emission and seeded coherent radiation. Its equivalent undulator period (λu) is 13.9 mm while it has achieved an equivalent magnetic field of 0.65 T. For future-generation light sources, this device promises a shorter undulator period, a large aperture, and fast dynamic control.