Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-31835369

ABSTRACT

Background: Smoking is the number one predictor for the development of periodontal disease. Consequently, electronic cigarette (ECIG) use has prompted investigations into the health-related risks induced by ECIG-generated aerosol on oral commensal bacteria as compared to cigarette smoke. Since E-liquid contains fewer constituents than smoke, we hypothesize that growth media containing E-liquid or aerosol has less impact on oral commensal streptococci than cigarette smoke. Methods: Eight-hour growth curves were generated for three strains of streptococci following exposure of growth media to nicotine alone (0.05, 0.1, 0.2 mg/mL), E-liquid ± nicotine (2.3, 4.7, 7.0 µL/mL), ECIG-generated aerosol ± nicotine (25, 50, 75 puffs), or cigarette smoke (2, 5, 10, 25, 50, 75 puffs). Nicotine and E-liquid were added to the media at concentrations equivalent to vaporized amounts of 25, 50, or 75 puffs. Absorbance readings were taken at 0, 2, 4, 6, and 8 h of bacterial growth. Results: Both E-liquid and aerosol (±nicotine) had little to no effect on eight-hour streptococcal growth. In contrast, five puffs of smoke inhibited streptococcal growth. Conclusions: Smoke-treated growth media, but not E-liquid or ECIG-generated aerosol, inhibits the growth of oral commensal streptococci. A possible implication is that aerosol may induce less periodontitis than smoke.


Subject(s)
Nicotine/adverse effects , Plankton/drug effects , Smoke/adverse effects , Streptococcus/drug effects , Streptococcus/growth & development , Tobacco Smoking , Vaping , Adult , Female , Humans , Male , Middle Aged
2.
Article in English | MEDLINE | ID: mdl-31438499

ABSTRACT

E-liquid manufacturers are under scrutiny concerning the purity and concentration accuracy of nicotine and the minor nicotine-related alkaloids (NRAs) packaged in their products. In this communication we report concentrations of nicotine and five NRAs (nornicotine, cotinine, anabasine, anatabine, myosmine) from locally purchased E-liquids. METHODS: Five brands of E-liquids (three bottles each) were purchased locally. Additionally, three bottles of reference E-liquid were prepared. Concentrations of nicotine and NRAs from each bottle were measured by HPLC. Concentrations of these alkaloids were also determined from electronic cigarette-generated aerosol and traditional cigarette smoke. RESULTS: Nicotine concentrations in E-liquid brands 1, 2, 3, 4, 5 and in the reference E-liquid were 17.8 ± 4.1, 23.2 ± 0.7, 24.0 ± 0.9, 24.9 ± 0.2, 19.7 ± 0.3 and 20.4 ± 0.1 mg/mL, respectively. Concentrations normalized to 100% of product label were 74%, 97%, 100%, 104%, 109% and 102%, respectively. E-liquid brand 1 showed significance (p < 0.001) between bottles, while the reference showed the least variability. Similar results were obtained for the NRAs. Results also indicated the NRAs in aerosol of the reference E-liquid are lower than in cigarette smoke. CONCLUSIONS: The amounts of NRAs present in E-liquids and E-liquid aerosol are less compared to cigarettes, however, inconsistencies and variation in nicotine concentrations supports the need for regulatory oversight.


Subject(s)
Alkaloids/analysis , Electronic Nicotine Delivery Systems , Aerosols , Chromatography, High Pressure Liquid , Smoke/analysis , Nicotiana
3.
Article in English | MEDLINE | ID: mdl-31091650

ABSTRACT

Background: The use of electronic cigarettes (ECIG) has become very common. Consequently, critical analysis of the biological effects of ECIG aerosol deserves attention. Flavorless ECIG aerosol is known to comprise fewer harmful constituents than cigarette smoke. Therefore, we hypothesize that aerosol has less immediate effect on the viability of oral commensal streptococci than smoke. Methods: Survival and growth of four strains of commensal streptococci were measured after exposure to flavorless ECIG aerosol ± nicotine and smoke. Peristaltic pumps were used to transport aerosol or smoke into chambers containing recently seeded colony-forming units (CFUs) of the oral commensal streptococci on agar plates. Bacterial survival and growth, based on colony counts and sizes, were determined 24 h post-exposure. Additionally, aerosol or smoke were delivered into chambers containing pre-adhered streptococci to plastic coverslips and biofilm formation was determined 24 h post-exposure via scanning electron microscopy. Results: The results suggest that flavorless aerosol ± nicotine has a modest effect on bacterial growth both as colonies on agar and as biofilms. In contrast, smoke dramatically decreased bacterial survival and growth in all parameters measured. Conclusion: Unlike cigarette smoke, flavorless ECIG aerosol has only a small effect on the survival and growth of oral commensal streptococci.


Subject(s)
Electronic Nicotine Delivery Systems , Nicotiana , Nicotine/adverse effects , Smoke/adverse effects , Streptococcus/drug effects , Aerosols , Streptococcus/growth & development
4.
J Org Chem ; 82(23): 12757-12762, 2017 12 01.
Article in English | MEDLINE | ID: mdl-29110479

ABSTRACT

Tetrahydro-1,4-azaborines were accessed by hydroboration of N,N-diprenyltoluenesulfonamide 4. Conversion to the methylborinates 11 and 12 followed by heating with l-alanine and crystallization afforded (R,R,S)-13 (27%). Reduction of borinic acid (R,R)-18 with Soderquist's KH* gave (R,R)-19, and hydride abstraction by TMSCl in the presence of alkenes resulted in hydroboration, 84-86% ee for (Z)-alkenes, but (E)-alkenes or 1,1-disubstituted alkenes gave <5% ee.


Subject(s)
Azo Compounds/chemistry , Boranes/chemistry , Alkenes/chemistry , Molecular Structure , Stereoisomerism
5.
Front Physiol ; 8: 1023, 2017.
Article in English | MEDLINE | ID: mdl-29321743

ABSTRACT

Background: While ECIGs are under scrutiny concerning safety, particularly in reference to the physiological impact that aerosolized ECIG liquid (E-liquid) may have on respiratory tissues, others believe that ECIGs are a "Harm Reduction" alternative to conventional cigarettes. Previous studies investigating ciliated respiratory epithelium indicate that smoking shortens cilia length, reduces cilia beat frequency and disrupts respiratory epithelium, which most likely contributes to the inhibition of mucocilliary clearance. Monitoring mucous clearance of respiratory tissues exposed to ECIG-generated aerosol or conventional cigarette smoke, as indexed by mucous transport velocity (MTV), is one way to gauge the impact aerosol and smoke have on the respiratory tract. Therefore, we designed an experiment to test the effect of ECIG-generated aerosol and smoke on MTV using the frog palate paradigm. Methods: Peristaltic pumps transport ECIG-generated aerosol and conventional cigarette smoke into custom-made chambers containing excised bullfrog palates. MTVs were determined before exposure, immediately after exposure and approximately 1 day following exposure. MTVs were also determined (at the same time points) for palates exposed to air (control). Surface and cross sectional SEM images of palates from all three groups were obtained to support MTV data. Results: The results indicate that ECIG-generated aerosol has a modest inhibitory effect (p < 0.05) on MTV 1 day post-exposure (0.09 ± 0.01) compared to control MTV (0.16 ± 0.03 mm/s). In contrast, smoke completely inhibits MTV from 0.14 ± 0.03 mm/s immediately before exposure to 0.00 mm/sec immediately after exposure and the MTV is unable to recover 1 day later. SEM images of control palates and palates exposed to ECIG-generated aerosol both show cilia throughout their epithelial surface, while some areas of palates exposed to smoke are completely devoid of cilia. Additionally, the epithelial thickness of aerosol-exposed palates appears thicker than control palates while smoke-exposed palates appear to be thinner due to epithelial disruption. Conclusions: These results indicate that ECIG-generated aerosol has only a modest effect on mucocilary clearance of bullfrog palates and aerosol sedimentation accounts for epithelial thickening. In accordance with the primary literature, conventional cigarette smoke dramatically inhibits mucociliary clearance and is, in part, due to decreased number of cilia and disruption of the smoke-exposed epithelium.

6.
Front Physiol ; 7: 663, 2016.
Article in English | MEDLINE | ID: mdl-28119618

ABSTRACT

Introduction: ECIGs are currently under scrutiny concerning their safety, particularly in reference to the impact ECIG liquids (E-liquids) have on human health. One concern is that aerosolized E-liquids contain trace metals that could become trapped in respiratory tissues and induce pathology. Methods: To mimic this trapping, peristaltic pumps were used to generate and transport aerosol onto mixed cellulose ester (MCE) membranes where aluminum (Al), arsenic (As), cadmium (Cd), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), lead (Pb), and zinc (Zn) were subsequently captured and quantified. The presence of trace metals on unexposed MCE membranes and on MCE membranes exposed to mainstream smoke served as control and comparison, respectively. The presence of these metals was also determined from the E-liquid before aerosolization and untouched by the ECIG device. All metals were quantified using ICP-MS. The ECIG core assembly was analyzed using scanning electron microscopy with elemental analysis capability. Results: The contents (µg) of Al, As, Cd, Cu, Fe, Mn, Ni, Pb, and Zn on control MCE membranes were 1.2 ± 0.2, 0.050 ± 0.002, 0.047 ± 0.003, 0.05 ± 0.01, 0.001 ± 0.001, 0.16 ± 0.04, 0.005 ± 0.003, 0.014 ± 0.006, and 0.09 ± 0.02, respectively. The contents of all trace metals on MCE membranes exposed to aerosol were similar to controls, except Ni which was significantly (p < 0.01) higher (0.024 ± 0.004 µg). In contrast, contents of Al, As, Fe, Mn, and Zn on MCE membranes exposed to smoke were significantly higher (p < 0.05) than controls. The contents of Al, As, Cu, Fe, and Mn on smoke-exposed MCE membranes were also significantly higher (p < 0.05) than their content on aerosol-exposed membranes. The contents per cigarette equivalent of metals in E-liquid before aerosolization were negligible compared to amounts of aerosolized E-liquid, except for Fe (0.002 µg before and 0.001 µg after). Elemental analysis of the core assembly reveals the presence of several of these trace metals, especially Al, Fe, Ni, and Zn. Conclusions: In general, from the single ECIG-device/E-liquid combination used, the amount of trace metals from ECIG-generated aerosol are lower than in traditional mainstream smoke, Only Ni in the ECIG-generated aerosol was higher than control. The most probable source of Ni in this aerosol is the core assembly.

7.
Org Lett ; 12(22): 5085-7, 2010 Nov 19.
Article in English | MEDLINE | ID: mdl-20945857

ABSTRACT

The palladium-catalyzed coupling of an aziridinylzinc chloride intermediate with alkenyl and aryl halides has been demonstrated. The method provides products with retention of aziridine stereochemistry. The utility of the coupling procedure is illustrated in the synthesis of structures related to l-furanomycin.


Subject(s)
Alkenes/chemistry , Amino Acids/chemical synthesis , Aziridines/chemistry , Hydrocarbons, Halogenated/chemistry , Palladium/chemistry , Amino Acids/chemistry , Catalysis , Chlorides/chemistry , Combinatorial Chemistry Techniques , Molecular Structure , Stereoisomerism , Zinc Compounds/chemistry
8.
Appl Radiat Isot ; 61(5): 733-8, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15308136

ABSTRACT

A broad experimental campaign to validate the final epithermal neutron beam design for the BNCT facility constructed at the University of Birmingham concluded in November 2003. The final moderator and facility designs are overviewed briefly, followed by a summary of the dosimetric methods and presentation of a small subset of the results from this campaign. The dual ionisation chamber technique was used together with foil activation to quantify the fast neutron, photon, and thermal neutron beam dose components in a large rectangular phantom exposed to the beam with a 12 cm diameter beam delimiter in place. After application of a normalisation factor, dose measurements agree with in-phantom MCNP4C predictions within 10% for the photon dose, within 10% for thermal neutron dose, and within 25% for the proton recoil dose along the main beam axis.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Phantoms, Imaging , Boron Neutron Capture Therapy/methods , Boron Neutron Capture Therapy/statistics & numerical data , Humans , In Vitro Techniques , Models, Theoretical , Radiometry/instrumentation , Radiometry/statistics & numerical data , Radiotherapy Dosage , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL
...