Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Clin Chim Acta ; 552: 117688, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38049046

ABSTRACT

BACKGROUND AND OBJECTIVE: Recent guidelines classify low prolactin levels as low as <7 ng/mL and high levels as >25 ng/mL, while the "Homeostatically Functionally Increased Transient Prolactinemia" (HomeoFIT-PRL) range (25-100 ng/mL) suggests that a temporary increase in prolactin could be metabolically beneficial if no related health issues are present. The aim of this study was to investigate the association between mean prolactin concentrations and disturbances in glycidic and lipidic metabolism and to identify the gray zone associated with prolactin inflection points that correlate with these metabolic changes. METHODS: This cross-sectional study involved 65,795 adults who underwent HOMA-IR, glucose, insulin, total cholesterol, HDL-c, LDL-c, and triglyceride tests. Data was categorized into 106 partitions based on prolactin results. Employing an approach referred to in this study as "Hierarchical Multicriteria Analysis of Differences Between Groups - Statistical and Effect Size Approach" (HiMADiG-SESA) comparing the mean concentrations of metabolic tests across prolactin ranges. A machine learning model was utilized to determine inflection points and their corresponding confidence intervals (CIs). These CIs helped establish gray zones in mean prolactin results related to metabolic changes. RESULTS: Statistically and clinically, metabolic test means differed for prolactin <7 ng/mL, except insulin. In the HomeoFIT-PRL range, means were lower except for HDL-c. The gray zones of the mean prolactin results associated with changes in glycidic and lipidic metabolism were 9.58-12.87 ng/mL and 13.81-18.73 ng/mL, respectively. CONCLUSION: A strong correlation was identified between mean prolactin concentrations and the results of metabolism tests below the gray zones associated with inflection points, indicating the potential role of prolactin in the appearance of metabolic disorders. Mean prolactin results can provide deeper insight into metabolic balance.


Subject(s)
Metabolic Diseases , Prolactin , Adult , Humans , Cross-Sectional Studies , Insulin/metabolism , Homeostasis
2.
Genes (Basel) ; 12(1)2021 Jan 13.
Article in English | MEDLINE | ID: mdl-33450867

ABSTRACT

In February 2020, our laboratory started to offer a RT-qPCR assay for the qualitative detection of severe acute respiratory syndrome coronavirus 2. A few months after the assay was released to our patients, some materials, reagents, and equipment became in short supply. Alternative protocols were necessary in order to avoid stopping testing to the population. However, the suitability of these alternatives needs to be validated before their use. Here, we investigated if saliva is a reliable alternative specimen to nasopharyngeal swabs; if 0.45% saline is a reliable alternative to guanidine hydrochloride as a collection viral transport media; the stability of SARS-COV-2 in guanidine hydrochloride and in 0.45% saline for 10 and 50 days at room temperature; and if the primers/probe concentration and thermocycling times could be reduced so as to overcome the short supply of these reagents and equipment, without a significant loss of the assay performance. We found that saliva is not an appropriated specimen for our method-nasopharyngeal swabs perform better. Saline (0.45%) and guanidine hydrochloride have a similar SARS-CoV-2 diagnostic capability as tube additives. Reliable SARS-CoV-2 RNA detection can be performed after sample storage for 10 days at room temperature (18-23 °C) in both 0.45% saline and guanidine hydrochloride. Using synthetic RNA, and decreasing the concentration of primers by five-fold and probes by 2.5-fold, changed the assay limit of detection (LOD) from 7.2 copies/reaction to 23.7 copies/reaction and the subsequent reducing of thermocycling times changed the assay LOD from 23.7 copies/reaction to 44.2 copies/reaction. However, using real clinical samples with Cq values ranging from ~12.15 to ~36.46, the results of the three tested conditions were almost identical. These alterations will not affect the vast majority of diagnostics and increase the daily testing capability in 30% and increase primers and probe stocks in 500% and 250%, respectively. Taken together, the alternative protocols described here overcome the short supply of tubes, reagents and equipment during the SARS-CoV-2 pandemic, avoiding the collapse of test offering for the population: 105,757 samples were processed, and 25,156 SARS-CoV-2 diagnostics were performed from 9 May 2020 to 30 June 2020.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19 , RNA, Viral , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/genetics , Female , Humans , Male , RNA, Viral/genetics , RNA, Viral/metabolism , SARS-CoV-2/genetics , SARS-CoV-2/metabolism
3.
Genes (Basel) ; 11(10)2020 10 12.
Article in English | MEDLINE | ID: mdl-33053675

ABSTRACT

WHO declared the novel coronavirus (COVID-19) outbreak a global pandemic on 11 March 2020. The establishment of standardized RT-qPCR protocols for respiratory secretions testing, as well as sharing of specimens, data, and information became critical. Here, we investigate the analytical performance of two interim RT-qPCR protocols (Charité and Centers for Disease Control (CDC)) for the qualitative detection of SARS-CoV-2 executed in a fully automated platform. Analytical specificity, PCR amplification efficiency, analytical sensitivity (limit of detection), and cross-reactivity were evaluated using contrived samples. The on-going accuracy was evaluated by retrospective analysis of our test results database (real clinical samples). N1, E, and a modified version of RdRP assays presented adequate analytical specificity, amplification efficiency, and analytical sensitivity using contrived samples. The three assays were applied to all individuals who requested the SARS-CoV-2 molecular test assay in our laboratory and it was observed that N1 gave more positive results than E, and E gave more positive results than RdRP (modified). The RdRP and E were removed from the test and its final version, based on N1 assay only, was applied to 30,699 Brazilian individuals (from 19 February 2020 to 8 May 2020). The aggregated test results available in the database were also presented.


Subject(s)
Automation, Laboratory/standards , Clinical Laboratory Techniques/standards , Real-Time Polymerase Chain Reaction/standards , Reverse Transcriptase Polymerase Chain Reaction/standards , Automation, Laboratory/methods , COVID-19 Testing , COVID-19 Vaccines , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Humans , Limit of Detection , Real-Time Polymerase Chain Reaction/methods , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction/methods
4.
Diagnostics (Basel) ; 10(3)2020 Mar 12.
Article in English | MEDLINE | ID: mdl-32178286

ABSTRACT

Detection of the Janus Kinase-2 (JAK2) V617F mutation is a diagnostic criterion for myeloproliferative neoplasms, and high levels of mutant alleles are associated with worse outcomes. This mutation is usually tested on blood DNA by allele-specific qPCR (AS-qPCR) and measured using absolute quantification. However, some automated DNA extractions co-extracts of PCR inhibitors from blood and qPCR absolute quantification need increased efforts in order to maintain standard curves. JAK2 V617F can also be detected in serum using droplet digital PCR (ddPCR), a specimen with less inhibitors and favorable to automated extractions, but ddPCR instruments are not wide available as qPCR thermocyclers. Here, we evaluate whether JAK2 V617F could be accurately quantified by AS-qPCR using the 2-∆∆Cq method on blood DNA and validate the assay using gold-standard molecular diagnostic protocols. Next, we apply the validated method to assess if the mutation could be reliably detected/quantified in serum. JAK2 V617F could be quantified by AS-qPCR using the 2-∆∆Cq method-the assay was highly accurate (bias of 1.91%) compared to a commercial kit, highly precise (total CV% of 0.40%, 1.92%, 11.12% for samples with 93%, 54%, and 2.5% of mutant allele), highly sensitive (limit of detection of 0.15%), and demonstrated a linear detection response from 1.1% to 99.9%. Serum presented a higher mutant allele burden compared to the paired whole blood (mean of 4%), which allows for an increased JAK2 mutant detection rate and favors increased JAK2 V617F high-throughput analysis.

5.
Cytometry B Clin Cytom ; 94(6): 910-917, 2018 11.
Article in English | MEDLINE | ID: mdl-30328264

ABSTRACT

BACKGROUND: The cytometric flow osmotic fragility test (FC-OFT) was recently introduced. However, the test is still under development and some variables have not yet been fully tested. METHODS: The osmotic fragility of hereditary spherocytosis (HS) cases and healthy controls were evaluated by FC-OFT using a series of tubes containing decreasing concentrations of NaCl. The analyses were executed in fresh and incubated (37°C for 24 h) blood samples anticoagulated with EDTA and heparin. The percentages of residual red blood cells were used to plot the osmotic fragility curves. The OF curves of each tested condition were compared using the median corpuscular fragility (MCF). ROC curve analyses identified the most accurate NaCl concentrations for differentiation between HS cases and healthy controls. RESULTS: FC-OFT curves assumed a sigmoidal dose-response shape and the MCF of cases and controls were different in all instances. MCF comparisons revealed that incubation and anticoagulant have major and minor effects on the FC-OFT, respectively. One hundred percent of sensitivity and specificity was obtained from 5.5 to 6.0 g/L of NaCl in EDTA-treated fresh blood, from 6.0 to 8.0 g/L of NaCl in EDTA-treated incubated blood, and in none of the tested NaCl concentration in heparinized blood. CONCLUSIONS: EDTA is the anticoagulant of choice for the assay. Incubation at 37°C for 24 h increased its diagnostic capability. The most reliable NaCl concentration for the discrimination of HS case from controls was 6.0 g/L of NaCL in fresh EDTA-treated blood, and was 7.5 g/L of NaCl in incubated EDTA-treated blood. © 2018 International Clinical Cytometry Society.


Subject(s)
Anticoagulants/pharmacology , Erythrocytes/drug effects , Osmotic Fragility/drug effects , Sodium Chloride/analysis , Spherocytosis, Hereditary/drug therapy , Adult , Case-Control Studies , Female , Flow Cytometry , Humans , Male , ROC Curve , Spherocytosis, Hereditary/diagnosis
8.
Clin Biochem ; 48(15): 976-81, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25746148

ABSTRACT

OBJETIVES: The extracellular DNA occurring in plasma-EDTA and serum is a biomarker of growing interest, especially in prenatal diagnosis and oncology. The objectives of the present study were to compare the DNase activity in these specimens and to investigate its ex-vivo impact over the circulating cell-free DNA yield (ccfDNA), using the circulating cell-free fetal DNA (ccffDNA) as a tool. DESIGN AND METHODS: EDTA-plasma and serum from women bearing male fetus were submitted to an endogenous DNase activity assay based on qPCR hydrolysis probe degradation, they were treated with DNAse I to investigate the action of an exogenous nuclease and also submitted to different temperature conditions to investigate the temperature-dependent degradation of the ccffDNA. In all instances, all male ccffDNA were quantified by qPCR targeting the Y chromosome-specific sequence DYS-14. Moreover, a serial dilution of EDTA was added to nonanticoagulated plasma and serum before the endogenous DNAse activity assay, to investigate the EDTA-mediated inhibition of the blood's DNase. RESULTS: The endogenous nuclease activity was 14.9-fold higher in serum compared to EDTA-plasma. The DNAse I treatment did not alter the ccffDNA yields in EDTA-plasma, but completely degraded it in serum. The addition of increasing doses of EDTA to nonanticoagulated plasma and serum resulted in a stepwise inhibition of their nucleases activity. Finally, we observed a much more pronounced temperature-mediated decrease on the ccffDNA amount in serum compared to EDTA-plasma. CONCLUSION: The exogenous and endogenous DNases are more active in serum, the anticoagulant EDTA indirectly inhibits blood DNases, and consequently ccfDNA is protected from the blood's DNase preanalytical impact in EDTA-plasma.


Subject(s)
Anticoagulants/pharmacology , Calcium Chelating Agents/pharmacology , DNA/blood , Deoxyribonucleases/antagonists & inhibitors , Edetic Acid/pharmacology , Enzyme Inhibitors/pharmacology , Biomarkers/blood , Biomarkers/metabolism , Chromosomes, Human, Y/metabolism , DNA/metabolism , Deoxyribonuclease I/antagonists & inhibitors , Deoxyribonuclease I/blood , Deoxyribonuclease I/metabolism , Deoxyribonucleases/blood , Deoxyribonucleases/metabolism , Female , Genetic Testing/methods , Humans , Hydrolysis/drug effects , Male , Molecular Diagnostic Techniques/methods , Plasma/chemistry , Plasma/drug effects , Plasma/enzymology , Pregnancy , Prenatal Diagnosis/methods , Serum/chemistry , Serum/drug effects , Serum/enzymology , Temperature
9.
Forensic Sci Int Genet ; 15: 105-10, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25434746

ABSTRACT

The aim of this study is to determine the fetus Y-STR haplotype in maternal plasma during pregnancy and estimate, non-invasively, if the alleged father and fetus belong to the same male lineage. The study enrolled couples with singleton pregnancies and known paternity. All participants signed informed consent and the local ethics committee approved the study. Peripheral blood was collected in EDTA tubes (mother) and in FTA paper (father). Maternal plasma DNA was extracted by using NucliSens EasyMAG. Fetal gender was determined by qPCR targeting DYS-14 in maternal plasma and it was also confirmed after the delivery. From all included volunteers, the first consecutive 20 mothers bearing male fetuses and 10 mothers bearing female fetuses were selected for the Y-STR analysis. The median gestational age was 12 weeks (range 12-36). All DNA samples were subjected to PCR amplification by PowerPlex Y23, ampFLSTR Yfiler, and two in-house multiplexes, which together accounts for 27 different Y-STR. The PCR products were detected with 3500 Genetic Analyzer and they were analyzed using GeneMapper-IDX. Fetuses' haplotypes (Yfiler format) were compared to other 5328 Brazilian haplotypes available on Y-chromosome haplotypes reference database (YHRD). As a result, between 22 and 27 loci were successfully amplified from maternal plasma in all 20 cases of male fetuses. None of the women bearing female fetuses had a falsely amplified Y-STR haplotype. The haplotype detected in maternal plasma completely matched the alleged father haplotype in 16 out of the 20 cases. Four cases showed single mismatches and they did not configure exclusions; 1 case showed a mutation in the DYS 458 locus due to the loss of one repeat unit and 3 cases showed one DYS 385I/II locus dropout. All mismatches were confirmed after the delivery. Seventeen fetuses' haplotypes were not found in YHRD and one of them had a mutation, which corresponded to the paternity probability of 99.9812% and 95.7028%, respectively. Three fetuses' haplotypes occurred twice in YHRD, which corresponded to paternity probability of 99.9437%. In conclusion, high discriminatory fetal Y-STR haplotype could be determined from maternal plasma during pregnancy starting at 12 weeks of gestation. All male fetuses could be attributed to the alleged father male lineage early in pregnancy. The high probability of paternity associated with each case suggests that the relationship is not random and this strategy can be use as an alternative for male fetal kinship analysis.


Subject(s)
Chromosomes, Human, Y , Fetus/metabolism , Haplotypes , Microsatellite Repeats/genetics , Pregnancy/blood , Female , Humans , Infant, Newborn , Male , Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL
...