Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Publication year range
1.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1488527

ABSTRACT

The tensiometer has been largely used for proper irrigation scheduling due to its simplicity, low cost and satisfactory precision. Although there is an increasing tendency of using fertirrigation, experimental data relating this practice to the cup hydraulic conductance and response time of the tensiometer are not available. The present study aimed to evaluate the changes on the hydraulic conductance (CH) and on the response time (TR) of ceramic cups after the cups were submitted to the following treatments: (a) immersion for 30 days in fertilizer solution with increasing concentrations; (b) use to monitor water availability to pepper grown in sandy and clay soils under irrigation and fertirrigation. CH increased and TR decreased accordingly to the increasing fertilizer solution concentration after immersion; CH decreased after the field trial with pepper; fertilizers added to the irrigation water did not influence CH and TR; soil texture did not affect CH and TR at 60 kPa tension.


O tensiômetro tem sido largamente utilizado como ferramenta no manejo da irrigação, tendo em vista sua praticidade, baixo custo e satisfatória precisão na determinação da tensão de água do solo. Com a tendência crescente do uso da fertirrigação, não se dispõe de dados a respeito das possíveis interações desta prática na condutância hidráulica e no tempo de resposta das cápsulas de cerâmica utilizadas nos tensiômetros. O trabalho procurou avaliar possíveis alterações na condutância hidráulica (CH) e no tempo de resposta (TR) de cápsulas de cerâmica após as mesmas terem sido submetidas aos seguintes tratamentos: (a) imersão pelo período de 30 dias em solução fertilizante com concentrações iônicas crescentes; (b) utilização no monitoramento da disponibilidade hídrica da cultura do pimentão cultivado em solo arenoso e argiloso, sob irrigação e fertirrigação. Verificou-se aumento da condutância hidráulica e redução dos tempos de resposta com o aumento da concentração da solução a que as cápsulas foram imersas; redução da condutância hidráulica após o período de cultivo do pimentão; não influência do acréscimo de fertilizantes à água de irrigação nas características avaliadas; não influência da textura do solo na condutância hidráulica e no tempo de resposta a tensão de 60 kPa.

2.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1488534

ABSTRACT

The objective of this study was to construct and evaluate a cups anemometer (prototype) with digital readings of instantaneous, average and maximum wind speeds, using cheap and easy building materials. The prototype sensor is compound of three ladles fixed to a rotor mounted on a spindle free. The gauge consists of a permanent magnet, where a spindle rotates the pole. This produces a variable magnetic field, which indicates directly the wind speed in a crystal liquid display. The prototype calibration was performed in the laboratory, at a wind tunnel, comparing its speed with values measured by a highly accurate standard anemometer. The results showed that the prototype presented a starting speed of 0.70 m.s-1 and the digital measure presented sensibility for speedreadings above 0.85 m.s-1. There were no differences (P 0.05) between the wind speeds measured with the prototype and the standard anemometer.


Este trabalho teve como objetivos construir e avaliar um anemômetro de copos (protótipo) com leitura digital da velocidade instantânea, média e máxima do vento, utilizando materiais de baixo custo e de fácil construção. O sensor do protótipo é do tipo copos rotativos (3) presos em hastes que são unidas a um eixo central comum. O sistema medidor consiste de um magneto permanente, girando com o eixo central, produzindo um campo magnético variável, que indica diretamente a velocidade do vento no display de cristal líquido. A avaliação do protótipo foi realizada em um túnel de vento comparando a velocidade do protótipo com a de um anemômetro de alta precisão, denominado padrão. Os resultados mostraram que o protótipo apresentou velocidade de partida de 0,70 m.s-1 e o medidor digital apresentou sensibilidade para leituras de velocidades acima de 0,85 m.s-1. As velocidades observadas pelo protótipo não apresentaram diferenças (P 0,05) em relação às velocidades do anemômetro padrão.

3.
R. Ci. agrovet. ; 4(1): 11-16, 2005.
Article in Portuguese | VETINDEX | ID: vti-714243

ABSTRACT

The objective of this study was to construct and evaluate a cups anemometer (prototype) with digital readings of instantaneous, average and maximum wind speeds, using cheap and easy building materials. The prototype sensor is compound of three ladles fixed to a rotor mounted on a spindle free. The gauge consists of a permanent magnet, where a spindle rotates the pole. This produces a variable magnetic field, which indicates directly the wind speed in a crystal liquid display. The prototype calibration was performed in the laboratory, at a wind tunnel, comparing its speed with values measured by a highly accurate standard anemometer. The results showed that the prototype presented a starting speed of 0.70 m.s-1 and the digital measure presented sensibility for speedreadings above 0.85 m.s-1. There were no differences (P 0.05) between the wind speeds measured with the prototype and the standard anemometer.


Este trabalho teve como objetivos construir e avaliar um anemômetro de copos (protótipo) com leitura digital da velocidade instantânea, média e máxima do vento, utilizando materiais de baixo custo e de fácil construção. O sensor do protótipo é do tipo copos rotativos (3) presos em hastes que são unidas a um eixo central comum. O sistema medidor consiste de um magneto permanente, girando com o eixo central, produzindo um campo magnético variável, que indica diretamente a velocidade do vento no display de cristal líquido. A avaliação do protótipo foi realizada em um túnel de vento comparando a velocidade do protótipo com a de um anemômetro de alta precisão, denominado padrão. Os resultados mostraram que o protótipo apresentou velocidade de partida de 0,70 m.s-1 e o medidor digital apresentou sensibilidade para leituras de velocidades acima de 0,85 m.s-1. As velocidades observadas pelo protótipo não apresentaram diferenças (P 0,05) em relação às velocidades do anemômetro padrão.

4.
R. Ci. agrovet. ; 4(1): 3-10, 2005.
Article in Portuguese | VETINDEX | ID: vti-713964

ABSTRACT

The tensiometer has been largely used for proper irrigation scheduling due to its simplicity, low cost and satisfactory precision. Although there is an increasing tendency of using fertirrigation, experimental data relating this practice to the cup hydraulic conductance and response time of the tensiometer are not available. The present study aimed to evaluate the changes on the hydraulic conductance (CH) and on the response time (TR) of ceramic cups after the cups were submitted to the following treatments: (a) immersion for 30 days in fertilizer solution with increasing concentrations; (b) use to monitor water availability to pepper grown in sandy and clay soils under irrigation and fertirrigation. CH increased and TR decreased accordingly to the increasing fertilizer solution concentration after immersion; CH decreased after the field trial with pepper; fertilizers added to the irrigation water did not influence CH and TR; soil texture did not affect CH and TR at 60 kPa tension.


O tensiômetro tem sido largamente utilizado como ferramenta no manejo da irrigação, tendo em vista sua praticidade, baixo custo e satisfatória precisão na determinação da tensão de água do solo. Com a tendência crescente do uso da fertirrigação, não se dispõe de dados a respeito das possíveis interações desta prática na condutância hidráulica e no tempo de resposta das cápsulas de cerâmica utilizadas nos tensiômetros. O trabalho procurou avaliar possíveis alterações na condutância hidráulica (CH) e no tempo de resposta (TR) de cápsulas de cerâmica após as mesmas terem sido submetidas aos seguintes tratamentos: (a) imersão pelo período de 30 dias em solução fertilizante com concentrações iônicas crescentes; (b) utilização no monitoramento da disponibilidade hídrica da cultura do pimentão cultivado em solo arenoso e argiloso, sob irrigação e fertirrigação. Verificou-se aumento da condutância hidráulica e redução dos tempos de resposta com o aumento da concentração da solução a que as cápsulas foram imersas; redução da condutância hidráulica após o período de cultivo do pimentão; não influência do acréscimo de fertilizantes à água de irrigação nas características avaliadas; não influência da textura do solo na condutância hidráulica e no tempo de resposta a tensão de 60 kPa.

SELECTION OF CITATIONS
SEARCH DETAIL