Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Perinat Med ; 48(8): 787-791, 2020 Oct 25.
Article in English | MEDLINE | ID: mdl-32877365

ABSTRACT

Objectives The aim of the study was to determine carotid intima-media thickness (CIMT) values in patients who developed and did not develop preeclampsia (PE), and to determine whether CIMT values could be predictors of PE development. Methods The study included pregnant women who were examined by regular ultrasound examination at the Materno-Infantil Presidente Vargas Hospital (HMIPV) in Porto Alegre, Brazil, from April 2016 to September 2017. The examinations were performed every three months. Patients were divided into two groups. The first group included patients diagnosed with PE (n=21) and second group included patients who did not have PE (n=199). A high frequency ultrasound device (12 MHz) with a semi-automatic method was used to estimate CIMT. Results CIMT was significantly higher in pregnant women with PE than in women without PE (55±0.11 vs. 0.44±0.06, respectively; p<0.001). Using a cut-off value of 0.51 mm, CIMT had a specificity of 77.9% and sensitivity of 81% in the diagnosis of PE. With CIMT ≥0.6 mm, the probability of a patient developing PE was 44.4%; with CIMT >0.42 mm, the probability was only 4.2%. Conclusions An increase in CIMT was associated with the onset of PE. CIMT values were significantly higher in patients who develop PE.


Subject(s)
Carotid Arteries , Pre-Eclampsia/diagnosis , Ultrasonography/methods , Adult , Brazil/epidemiology , Carotid Arteries/diagnostic imaging , Carotid Arteries/pathology , Carotid Intima-Media Thickness , Female , Humans , Pre-Eclampsia/epidemiology , Predictive Value of Tests , Pregnancy , Prognosis , Risk Assessment/methods , Risk Factors , Sensitivity and Specificity
2.
J Perinat Med ; 45(6): 717-727, 2017 Aug 28.
Article in English | MEDLINE | ID: mdl-28493821

ABSTRACT

Assessment of fetal neurobehavior and detection of neurological impairment prenatally has been a great challenge in perinatal medicine. The evolution of four-dimensional (4D) ultrasound not only enabled a better visualization of fetal anatomy but also allowed the study of fetal behavior in real time. Kurjak Antenatal Neurodevelopmental Test (KANET) was developed for the assessment of fetal neurobehavior and the detection of neurological disorders, based on the assessment of the fetus by application of 4D ultrasound in the same way that a neonate is assessed postnatally. KANET is a method that has been applied for the past 10 years and studies show that it is a strong diagnostic tool and can be introduced into everyday clinical practice. We present all data from studies performed up to now on KANET.


Subject(s)
Fetal Movement , Ultrasonography, Prenatal/methods , Female , Humans , Imaging, Three-Dimensional , Multicenter Studies as Topic , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL
...