1.
Acta Otolaryngol ; 127(4): 378-83, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17453457

ABSTRACT

CONCLUSION: Neither speech understanding nor frequency discrimination ability was better in Nucleus Contour users than in Nucleus 24 straight electrode users. Furthermore, perimodiolar electrode placement does not result in better frequency discrimination. OBJECTIVES: We addressed three questions related to perimodiolar electrode placement. First, do patients implanted with the Contour electrode understand speech better than with an otherwise identical device that has a straight electrode? Second, do these groups have different frequency discrimination abilities? Third, is the distance of the electrode from the modiolus related to frequency discrimination ability? SUBJECTS AND METHODS: Contour and straight electrode users were matched on four important variables. We then tested these listeners on CNC word and HINT sentence identification tasks, and on a formant frequency discrimination task. We also examined X-rays and measured the distance of the electrodes from the modiolus to determine whether there is a relationship between this factor and frequency discrimination ability. RESULTS: Both speech understanding and frequency discrimination abilities were similar for listeners implanted with the Contour vs a straight electrode. Furthermore, there was no linear relationship between electrode-modiolus distance and frequency discrimination ability. However, we did note a second-order relationship between these variables, suggesting that frequency discrimination is worse when the electrodes are either too close or too far away from the modiolus.


Subject(s)
Cochlear Implants , Electrodes, Implanted , Phonetics , Pitch Discrimination , Speech Perception , Adult , Equipment Failure Analysis , Female , Humans , Male , Middle Aged , Prosthesis Design , Sound Spectrography , Speech Discrimination Tests
2.
Audiol Neurootol ; 8(5): 269-85, 2003.
Article in English | MEDLINE | ID: mdl-12904682

ABSTRACT

It is hypothesized that for postlingually deafened adult cochlear implant (CI) users, a significant source of their perceptual performance variability is attributable to differences in their ability to discriminate the basic perceptual cues that are important in speech recognition. Previous research on 'electric hearing' has identified consistent perceptual cues for vowel recognition. However, the results on consonant perception by CI users are less clear. The primary purpose of this study is to present a quantitative method of evaluating potential 'electric cues' used by CI users in consonant identification. Since the actual input signals to the auditory periphery of CI users are electric in nature, we elected to measure the CI electric discharge patterns in addition to the original acoustic waveforms. The characteristics of the electric discharge patterns in response to intervocalic consonants were quantified and correlated with the dimensions of CI patients' perceptual spaces, which were computed from multidimensional scaling analyses of their consonant confusion matrices. The results agree with most, but not all, commonly accepted acoustic cues used by normal-hearing listeners. The correlation findings also suggest that CI users employ different sets of 'electric cues' in perceiving consonants that differ in their manner of articulation. Specifically, spectral and temporal cues associated with slowly changing formant structures and transitions, and features associated with frication and high-frequency noise, are all highly correlated with the perceptual dimensions of all CI users. However, rapidly changing formant transitions, such as those present in stop consonants, did not appear to play a significant role in consonant recognition by more poorly performing CI subjects. The perceptual results were consistent with our physical findings that the SPEAK coding strategy partially degraded the rapidly changing formant transitions.


Subject(s)
Acoustic Stimulation , Auditory Threshold , Cochlear Implants , Cues , Electric Stimulation , Phonetics , Speech Perception , Adult , Electric Stimulation/instrumentation , Evaluation Studies as Topic , Hearing Loss/physiopathology , Hearing Loss/surgery , Humans , Regression Analysis