Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anesth Analg ; 122(4): 1070-8, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26836134

ABSTRACT

BACKGROUND: Diagnostic and interventional procedures are often facilitated by moderate procedure-related sedation. Many studies support the overall safety of this sedation; however, adverse cardiovascular and respiratory events are reported in up to 70% of these procedures, more frequently in very young, very old, or sicker patients. Monitoring with pulse oximetry may underreport hypoventilation during sedation, particularly if supplemental oxygen is provided. Capnometry may result in false alarms during sedation when patients mouth breathe or displace sampling devices. Advanced monitor use during sedation may allow event detection before complications develop. This 2-part pilot study used advanced monitors during planned moderate sedation to (1) determine incidences of desaturation, low respiratory rate, and deeper than intended sedation alarm events; and (2) determine whether advanced monitor use is associated with fewer alarm events. METHODS: Adult patients undergoing scheduled gastroenterology or interventional radiology procedures with planned moderate sedation given by dedicated sedation nurses under the direction of procedural physicians (procedural sedation team) were monitored per standard protocols (electrocardiography blood pressure, pulse oximetry, and capnometry) and advanced monitors (acoustic respiratory monitoring and processed electroencephalograpy). Data were collected to computers for analysis. Advanced monitor parameters were not visible to teams in part 1 (standard) but were visible to teams in part 2 (advanced). Alarm events were defined as desaturation-SpO2 ≤92%; respiratory depression, acoustic respiratory rate ≤8 breaths per minute, and deeper than intended sedation, indicated by processed electroencephalograpy. The number of alarm events was compared. RESULTS: Of 100 patients enrolled, 10 were excluded for data collection computer malfunction or consent withdrawal. Data were analyzed from 90 patients (44 standard and 46 advanced). Advanced had fewer total alarms than standard (Wilcoxon-Mann-Whitney = 2.073, P = 0.038; Wilcoxon-Mann-Whitney odds, 1.67; 95% confidence interval [CI], 1.04-2.88). Similar numbers of standard and advanced had ≥1 alarm event (Wald difference, -10.2%; 95% CI, -26.4% to 7.0%; P = 0.237). Fewer advanced patients had ≥1 respiratory depression event (Wald difference, -22.1%; 95% CI, -40.9% to -2.4%; P = 0.036) or ≥1 desaturation event (Wald difference, -24.2%; 95% CI, -42.8% to -3.6%; P = 0.021); but there was no significant difference in deeper than intended sedation events (Wald difference, -1.38%; 95% CI, -20.21% to 17.49%; P = 0.887). CONCLUSIONS: Use of advanced monitoring parameters during planned moderate sedation was associated with fewer alarm events, patients experiencing desaturation, and patients experiencing respiratory depression alarm events. This pilot study suggests that further study into the safety and outcome impacts of advanced monitoring during procedure-related sedation is warranted.


Subject(s)
Clinical Alarms/standards , Conscious Sedation/methods , Endoscopy, Gastrointestinal , Radiology, Interventional , Conscious Sedation/adverse effects , Endoscopy, Gastrointestinal/adverse effects , Female , Humans , Male , Middle Aged , Pilot Projects
2.
Birth ; 42(4): 319-28, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26463582

ABSTRACT

BACKGROUND: Intrapartum drugs, including fentanyl administered via epidural and synthetic oxytocin, have been previously studied in relation to neonatal outcomes, especially breastfeeding, with conflicting results. We examined the normal neonatal behavior of suckling within the first hour after a vaginal birth while in skin-to-skin contact with mother in relation to these commonly used drugs. Suckling in the first hour after birth has been shown in other studies to increase desirable breastfeeding outcomes. METHOD: Prospective comparative design. Sixty-three low-risk mothers self-selected to labor with intrapartum analgesia/anesthesia or not. Video recordings of infants during the first hour after birth while being held skin-to-skin with their mother were coded and analyzed to ascertain whether or not they achieved Stage 8 (suckling) of Widström's 9 Stages of newborn behavior during the first hour after birth. RESULTS: A strong inverse correlation was found between the amount and duration of exposure to epidural fentanyl and the amount of synthetic oxytocin against the likelihood of achieving suckling during the first hour after a vaginal birth. CONCLUSIONS: Results suggest that intrapartum exposure to the drugs fentanyl and synthetic oxytocin significantly decreased the likelihood of the baby suckling while skin-to-skin with its mother during the first hour after birth.


Subject(s)
Breast Feeding , Fentanyl , Labor, Obstetric , Maternal-Fetal Exchange/drug effects , Natural Childbirth/methods , Oxytocin , Sucking Behavior/drug effects , Adjuvants, Anesthesia/administration & dosage , Adjuvants, Anesthesia/adverse effects , Anesthesia, Epidural/methods , Breast Feeding/methods , Breast Feeding/statistics & numerical data , Female , Fentanyl/administration & dosage , Fentanyl/adverse effects , Humans , Infant, Newborn , Outcome Assessment, Health Care , Oxytocics/administration & dosage , Oxytocics/adverse effects , Oxytocin/administration & dosage , Oxytocin/adverse effects , Pregnancy , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...