1.
Int J Prosthodont ; 37(7): 13-17, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38489216

ABSTRACT

PURPOSE: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers. MATERIALS AND METHODS: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner. All data were exported in STL file format, processed, and sent to five 3D printers. Five casts were manufactured in each printer group: SG (CARES P20, Straumann); FG (Form 2, Formlabs); WG (Duplicator 7, Wanhao); ZG (Zenith D, Zenith); and MG (Moonray S100, Moonray). Measurements of the accuracy (trueness and precision) of the casts obtained from conventional elastomeric impressions and 3D-printing methods were accomplished using a 3D analysis software (Geomagic Control). RESULTS: The FG group showed the lowest values for trueness (indicating a value closer to real dimensions), which were similar to the SG group only (P > .05). MG, WG, and ZG groups presented higher values and were similar compared to each other. Data on precision demonstrated that all 3D-printed groups showed lower values for precision (smaller deviation) when compared to the CG. CONCLUSIONS: The trueness depends on the chosen 3D printer. All of the tested 3D printers were more precise than cast models obtained from conventional elastomeric impressions.


Subject(s)
Computer-Aided Design , Dental Implants , Printing, Three-Dimensional , Dental Impression Technique , Imaging, Three-Dimensional
2.
Healthcare (Basel) ; 11(18)2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37761669

ABSTRACT

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant's position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient.

3.
Dent Mater ; 39(8): 686, 2023 08.
Article in English | MEDLINE | ID: mdl-37357046

ABSTRACT

OBJECTIVES: This in vitro comparative study aimed to evaluate the physical and mechanical properties of four 3D-printed resins with two different thickness layers. METHODS: Four printed resins (VarseoSmile Crown Plus, VSC; NexDent C&B MFH, MFH; Nanolab 3D, NNL; and Resilab 3D Temp, RSL) were printed with 50 µm and 100 µm layer thickness, resulting in 80 bars measuring 25 × 2×2 mm. The specimens underwent a Raman spectroscopy for degree of conversion, confocal laser scanning microscopy for surface roughness (Sa), three-point bending test for flexural strength and elastic modulus, and a Vickers hardness test (VHN). Data was tested for normality using the Shapiro-Wilk, two-way ANOVA, and Tukey test (α = 0.05) for statistical analysis. RESULTS: The layer thickness affected all performed tests, but the elastic modulus (p < 0.001). Specimens with 100 µm showed, in general, worse results outcomes than those with 50 µm (p < 0.001). However, within the limitations of this comparative in vitro study, it could be concluded that the tested resins and layer thicknesses directly influenced physical and mechanical properties. SIGNIFICANCE: The physical and mechanical properties of three-dimensional printed restorations can be affected by the layer thickness, which can interfere with the choice of the 3D printing resin for a desired clinical outcome.


Subject(s)
Composite Resins , Dental Materials , Dental Materials/chemistry , Materials Testing , Flexural Strength , Printing, Three-Dimensional , Surface Properties
4.
Arq Neuropsiquiatr ; 81(1): 81-94, 2023 01.
Article in English | MEDLINE | ID: mdl-36918011

ABSTRACT

In the last few decades, there have been considerable improvements in the diagnosis and care of Duchenne muscular dystrophy (DMD), the most common childhood muscular dystrophy. International guidelines have been published and recently reviewed. A group of Brazilian experts has developed a standard of care based on a literature review with evidence-based graded recommendations in a two-part publication. Implementing best practice management has helped change the natural history of this chronic progressive disorder, in which the life expectancy for children of the male sex in the past used to be very limited. Since the previous publication, diagnosis, steroid treatment, rehabilitation, and systemic care have gained more significant insights with new original work in certain fields. Furthermore, the development of new drugs is ongoing, and some interventions have been approved for use in certain countries. Therefore, we have identified the need to review the previous care recommendations for Brazilian patients with DMD. Our objective was to create an evidence-based document that is an update on our previous consensus on those topics.


Nas últimas décadas, houve progressos significativos no diagnóstico e no tratamento da distrofia muscular de Duchenne (DMD), considerada a distrofia muscular mais comum na infância. Diretrizes internacionais foram publicadas e revisadas recentemente. Um grupo de especialistas brasileiros desenvolveu um padrão de atendimento baseado em revisão de literatura, com recomendações graduadas pautadas em evidências compiladas em uma publicação dividida em duas partes. A implementação de melhores práticas de manejo ajudou a modificar a história natural desta doença crônica, progressiva, que, no passado, oferecia uma expectativa de vida muito limitada para crianças do sexo masculino. Desde a publicação desse consenso anterior, o diagnóstico, o tratamento com esteroides, a reabilitação e os cuidados sistêmicos ganharam novas possibilidades a partir da divulgação dos resultados de trabalhos originais em algumas dessas áreas. Além disso, as pesquisas e o desenvolvimento de novos fármacos estão em andamento, e algumas intervenções já foram aprovadas para uso em determinados países. Nesse contexto, identificamos a necessidade de rever as recomendações anteriores sobre o manejo dos pacientes brasileiros com DMD. Nosso objetivo principal foi elaborar uma atualização baseada em evidências sobre esses tópicos do consenso.


Subject(s)
Muscular Dystrophy, Duchenne , Child , Humans , Male , Muscular Dystrophy, Duchenne/diagnosis , Brazil , Consensus
5.
J Clin Exp Dent ; 15(1): e71-e78, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36755677

ABSTRACT

In this work, we present 5 cases of Kennedy Class I patients with atrophic posterior mandible treated with the placement of 01 short WS Neodent® implant and a healing screw to support the removable prosthesis, transforming them into Kennedy Class III patients. To quickly evaluate and verify the benefit of this treatment, masticatory performance was evaluated with maximum bite force and chewing ability. A VAS questionnaire was also applied for a practical preoperative and postoperative evaluation of overall quality of life-changing for the patient after this treatment. This treatment plan was planned in order to reduce drastically the treatment costs and morbidity, and to enhance oral function and the quality of life for these patients. Also, this treatment lead to residual bone preservation, enhanced masticatory function and patient satisfaction. Especially in countries with a large number of patients with missing teeth and socio-economic difficulties to be fully rehabilitated with dental implants and fixed prosthesis treatment options with reduced costs are important to be in our armamentary os possibilities. Key words:Dental implants, masticatory performance, chewing, oral function, mixing ability.

6.
Arq. neuropsiquiatr ; 81(1): 81-94, Jan. 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1429889

ABSTRACT

Abstract In the last few decades, there have been considerable improvements in the diagnosis and care of Duchenne muscular dystrophy (DMD), the most common childhood muscular dystrophy. International guidelines have been published and recently reviewed. A group of Brazilian experts has developed a standard of care based on a literature review with evidence-based graded recommendations in a two-part publication. Implementing best practice management has helped change the natural history of this chronic progressive disorder, in which the life expectancy for children of the male sex in the past used to be very limited. Since the previous publication, diagnosis, steroid treatment, rehabilitation, and systemic care have gained more significant insights with new original work in certain fields. Furthermore, the development of new drugs is ongoing, and some interventions have been approved for use in certain countries. Therefore, we have identified the need to review the previous care recommendations for Brazilian patients with DMD. Our objective was to create an evidence-based document that is an update on our previous consensus on those topics.


Resumo Nas últimas décadas, houve progressos significativos no diagnóstico e no tratamento da distrofia muscular de Duchenne (DMD), considerada a distrofia muscular mais comum na infância. Diretrizes internacionais foram publicadas e revisadas recentemente. Um grupo de especialistas brasileiros desenvolveu um padrão de atendimento baseado em revisão de literatura, com recomendações graduadas pautadas em evidências compiladas em uma publicação dividida em duas partes. A implementação de melhores práticas de manejo ajudou a modificar a história natural desta doença crônica, progressiva, que, no passado, oferecia uma expectativa de vida muito limitada para crianças do sexo masculino. Desde a publicação desse consenso anterior, o diagnóstico, o tratamento com esteroides, a reabilitação e os cuidados sistêmicos ganharam novas possibilidades a partir da divulgação dos resultados de trabalhos originais em algumas dessas áreas. Além disso, as pesquisas e o desenvolvimento de novos fármacos estão em andamento, e algumas intervenções já foram aprovadas para uso em determinados países. Nesse contexto, identificamos a necessidade de rever as recomendações anteriores sobre o manejo dos pacientes brasileiros com DMD. Nosso objetivo principal foi elaborar uma atualização baseada em evidências sobre esses tópicos do consenso.

7.
J Prosthet Dent ; 129(2): 350-353, 2023 Feb.
Article in English | MEDLINE | ID: mdl-34218898

ABSTRACT

STATEMENT OF PROBLEM: When 3-dimensional printing casts, the operator can change the type of resin and the printing layer thickness, reducing the fabrication time. However, how these parameters affect the accuracy of 3-dimensionally printed casts is unknown. PURPOSE: The purpose of this in vitro study was to evaluate the accuracy of 3-dimensionally printed casts by using a stereolithography (SLA) 3-dimensional printer (Forms2) with 3 different layer thickness (25, 50, and 100 µm) and 2 different resins (Gray and Cast) and by comparing the time to obtain each cast. MATERIAL AND METHODS: One master cast was scanned, and a single file was printed several times. The printed casts were then scanned by using a laboratory scanner. The standard tessellation language (STL) files provided by the laboratory scanner were superimposed and compared by using a software program (Geomagic Control; 3D Systems). The 2-way ANOVA test was used for the trueness evaluation, followed by the Tukey test to identify differences among the groups (α=.05). RESULTS: No statistically significant differences in accuracy were found among the 3 different layers for either resin (P>.05). Printing time doubled as layer thickness decreased. CONCLUSIONS: This study showed that when printing casts, the fastest printing settings can be used without losing accuracy and that the laboratory digital workflow can be accelerated with selection of the resin and cast layer, as the type of resin and layer thickness did not influence the quality of the casts.


Subject(s)
Computer-Aided Design , Models, Dental , Printing, Three-Dimensional , Stereolithography , Software
8.
Int J Prosthodont ; 2022 Dec 06.
Article in English | MEDLINE | ID: mdl-36484676

ABSTRACT

PURPOSE: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers. MATERIALS AND METHODS: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner. All data were exported as an STL file format, processed, and sent to five 3D printers. Five casts were manufactured in each group: SG (CARES P20, Straumann); FG (Form 2, Formlabs); WG (Duplicator 7, Wanhao); ZG (Zenith D, Zenith); and MG (Moonray S100, Moonray). Measurements of the accuracy (trueness and precision) of the casts obtained from conventional elastomeric impressions and 3D-printing methods were accomplished using a 3D analysis software (Geomagic Control). RESULTS: The FG group showed the lowest values for trueness (closer to real dimensions), which were similar to the SG group only (P > .05). Groups MG, WG, and ZG presented higher values and were similar compared to each other. Data on precision demonstrated that all 3D-printed groups showed lower values for precision (smaller deviation) when compared to the control group. CONCLUSION: The trueness depends on the chosen 3D printer. All of the tested 3D printers were more precise than cast models obtained from conventional elastomeric impressions.

9.
Braz. j. oral sci ; 21: e226036, jan.-dez. 2022. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1393321

ABSTRACT

Dental implants could give back function, esthetics and quality of life to patients. The correct choice of the implant, especially in borderline cases, is essential for a satisfactory result. Aim: Thus, the objective of this study was to evaluate the mechanical behavior of Morse taper implants with two different prosthetic interfaces. Methods: Twenty self-locking Morse taper implants, 2.9 mm in diameter (FAC), and 20 Morse taper implants, 3.5 mm in diameter (CM) were divided into two groups (n=10), and submitted to strength to failure test, optical microscopic evaluation of fracture, metallographic analysis of the alloy, finite element analysis (FEA) and strain gauge test. A Student's t test (α = 0.05) was made for a statistical analysis. Results: For the strength to failure test, a statistically difference was observed (p <0.001) between FAC (225.0 ± 19.8 N) and CM (397.3 ± 12.5 N). The optical microscopic evaluation demonstrated a fracture pattern that corroborated with FEA ́s results. The metallographic analysis determined that the implants of the FAC group have titanium-aluminum-vanadium alloy in their composition. In the strain gauge test, there was no statistical difference (p = 0.833) between CM (1064.8 ± 575.04 µS) and FAC (1002.2 ± 657.6 µS) groups. Conclusion: Based on the results obtained in this study, ultra-narrow implants (FAC) should ideally be restricted to areas with low masticatory effort


Subject(s)
Tensile Strength , Dental Implantation , Flexural Strength
10.
Gen Dent ; 69(5): 62-66, 2021.
Article in English | MEDLINE | ID: mdl-34424215

ABSTRACT

The aim of this study was to evaluate the influence of the geometry of the screwdriver-screw connection on the reverse torque of UCLA screws after repeated cycles of tightening and loosening in an implant-supported prosthesis. Thirty sets of external hex titanium implants, UCLA abutments, and UCLA abutment screws were divided into 3 experimental groups (n = 10). In the square group, the implant and UCLA abutment system were mounted in an upright position using a screw with a square screwdriver-screw connection. In the hexagonal group, the implant and UCLA abutment system were mounted in an upright position using a screw with a hexagonal screwdriver-screw connection. In the hexalobular group, the implant and UCLA abutment system were mounted at 70° using a dynamic UCLA abutment and screw with a hexalobular screwdriver-screw connection. Ten alternating torque-reverse torque cycles were applied to each screw using a screwdriver fixed at the end of a digital torque meter. The screws with a square connection resulted in less loss of reverse torque than the other types. Screws with a hexagonal connection showed a statistically significant loss of torque initially but remained constant for the remaining cycles. For the screws with a hexalobular connection, the loss of torque was greater, and substantial deformation of the plastic in the microstructure was noted. The screwdriver-screw connection geometry had a direct influence on the reverse torque of UCLA screws, and the initial reverse torque of the abutment screws with a square connection was greater than that of the hexagonal and hexalobular designs.


Subject(s)
Dental Abutments , Dental Implants , Bone Screws , Dental Stress Analysis , Humans , Torque
11.
J Prosthet Dent ; 125(2): 294-299, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32115221

ABSTRACT

STATEMENT OF PROBLEM: Intraoral scanners (IOSs) have some inherent distortions caused by optical and/or software imperfections. However, how other factors such as operator experience, scan time, scanner type, and scan size influence scan accuracy is not clear. PURPOSE: The purpose of this in vitro study was to evaluate the trueness and precision of scans performed by 3 professionals with different levels of experience by using 2 IOSs. MATERIAL AND METHODS: Three operators with low, medium, and high levels of experience scanned a master model 10 times by using 2 IOSs (CEREC Omnicam; Dentsply Sirona and TRIOS 3; 3Shape), resulting in 10 standard tessellation language files for each group (N=60). Each standard tessellation language file was divided into 2 areas (prepared teeth and complete arch). Precision was evaluated by comparing the 10 scans from each examiner for each system. Trueness was evaluated by comparing each scan file with a reference scan obtained from a laboratory scanner (D2000; 3Shape). A 3D analysis software program (Geomagic Control; 3D Systems) was used to perform all the comparisons and superimpositions. The 3-way ANOVA test followed by the Tukey HSD test were used to assess precision and trueness. The 2-way ANOVA followed by the Tukey HSD test was used to assess scan time. The Pearson correlation test was performed between scan time and trueness for both scanners. An additional correlation was performed between scan time and number of images, as well as between number of images and trueness for the TRIOS 3. RESULTS: Statistically significant influences of operator (P<.001), scanner (P<.001), scan size (P<.001), operator and scan size (P<.001), and scanner and scan size (P<.001) were observed. The TRIOS 3 group reported higher precision than the CEREC Omnicam group for complete-arch scans (P<.001), although no difference was observed for scans of the prepared tooth. Medium- (P=.002) and low-experience operators (P<.001) reported lower precision for complete-arch scans performed with CEREC Omnicam when compared with TRIOS 3. The low-experience operator reported significantly worse results for complete-arch scans in comparison with the medium- (P=.008 and P<.001) and high-experience operators (P<.001 and P=.001), by using TRIOS 3 and CEREC Omnicam, respectively. Medium- and high-experience operators reported similar results among themselves. The CEREC Omnicam scanner reported lower trueness for complete-arch scans when compared with the prepared tooth (P<.001); for TRIOS 3, a difference was only observed for the low-experience operator when compared with the high-experience operator (P<.001). The CEREC Omnicam reported lower trueness than the TRIOS 3, except for the medium-experience operator with the prepared tooth scan. Comparing the trueness between operators and considering the same scanner and scan size, all groups were similar. The low-experience operator had a longer scanning time than the medium- and high-experience operators. For TRIOS 3, the low-experience operator obtained the highest number of images during each scan. CONCLUSIONS: The accuracy of intraoral scans was influenced by operator experience, type of IOSs, and scan size. More experienced operators and smaller scan sizes made for more accurate scans. In addition, more experienced operators made faster scans, and the TRIOS 3 was more accurate than the CEREC Omnicam for complete-arch scans.


Subject(s)
Dental Impression Technique , Models, Dental , Computer-Aided Design , Dental Arch , Imaging, Three-Dimensional
12.
Dent Mater ; 36(11): e340-e351, 2020 11.
Article in English | MEDLINE | ID: mdl-32950244

ABSTRACT

OBJECTIVE: To evaluate the effect of exposure time and moving the light-curing unit (LCU) on the degree of conversion (DC) and Knoop microhardness (KH) of two resin cements that were light-cured through ceramic. METHODS: Two resin cements: AllCem Veneer APS (FGM) and Variolink Esthetic LC (Ivoclar Vivadent) were placed into a 0.3 mm thick matrix in 6 locations representing the canine to canine. The resins were covered with 0.5 mm thick lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent). A motorized device moved the LCUs over the ceramic when the LCU was on. Two single-peak LCUs: Elipar DeepCure-L (3M Oral Care) and Emitter C (Schuster), and one multi-peak: Bluephase G2 (Ivoclar Vivadent) were used with 3 different exposure protocols: a localized exposure centered over each tooth for 10 or 40 s; moving the tip across the 6 teeth for a total exposure time of 10 or 40 s; and moving the tip across the 6 teeth resins for a total exposure time of 60 or 240 s. After 24 h, the DC and KH were measured on the top surfaces and the data was analyzed using three-way ANOVA and Tukey's tests (α = 0.05). RESULTS: Interposition of 0.5 mm of ceramic reduced the irradiance received by the resin by approximately 50%. The 40 s localized exposure over each tooth always produced significantly higher DC and KH values. Moving the LCUs with a total exposure time of 10 s resulted in the lowest DC and KH. There was no beneficial effect on the DC or KH when the multi-peak (violet-blue) LCU (Elipar DeepCure-L or Bluephase G2), but the lower light output from a small tip LCU reduced the DC and KH values (Emitter C). SIGNIFICANCE: Moving the LCUs when photo-curing light-cured resin cements is not recommended. This study showed that a single-peak LCU could activate a resin cement that uses Ivocerin™ as well as the multi-peak LCU.


Subject(s)
Curing Lights, Dental , Resin Cements , Composite Resins , Hardness , Materials Testing , Polymerization
13.
Braz Oral Res ; 34: e004, 2020.
Article in English | MEDLINE | ID: mdl-32022223

ABSTRACT

The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.


Subject(s)
Ceramics/chemistry , Computer-Aided Design , Dental Porcelain/chemistry , Glass/chemistry , Analysis of Variance , Dental Bonding/methods , Flexural Strength , Materials Testing , Microscopy, Electron, Scanning , Porosity , Reference Values , Reproducibility of Results , Resin Cements/chemistry , Shear Strength , Surface Properties , X-Ray Diffraction
14.
Braz. oral res. (Online) ; 34: e004, 2020. tab, graf
Article in English | LILACS | ID: biblio-1055523

ABSTRACT

Abstract The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.


Subject(s)
Ceramics/chemistry , Computer-Aided Design , Dental Porcelain/chemistry , Glass/chemistry , Reference Values , Surface Properties , X-Ray Diffraction , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Analysis of Variance , Porosity , Dental Bonding/methods , Resin Cements/chemistry , Shear Strength , Flexural Strength
15.
Sensors (Basel) ; 19(23)2019 Nov 22.
Article in English | MEDLINE | ID: mdl-31766772

ABSTRACT

This paper presents an omnidirectional RGB-D (RGB + Distance fusion) sensor prototype using an actuated LIDAR (Light Detection and Ranging) and an RGB camera. Besides the sensor, a novel mapping strategy is developed considering sensor scanning characteristics. The sensor can gather RGB and 3D data from any direction by toppling in 90 degrees a laser scan sensor and rotating it about its central axis. The mapping strategy is based on two environment maps, a local map for instantaneous perception, and a global map for perception memory. The 2D local map represents the surface in front of the robot and may contain RGB data, allowing environment reconstruction and human detection, similar to a sliding window that moves with a robot and stores surface data.

16.
J Prosthet Dent ; 122(1): 54.e1-54.e6, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31202549

ABSTRACT

STATEMENT OF PROBLEM: Narrow implants have limited indications, and implant fracture may occur when these indications are not followed. PURPOSE: The purpose of this in vitro study was to investigate the mechanical behavior of a 2.9-mm-diameter implant using a fatigue limit test and to investigate the Morse effect of 2 different Morse taper systems, 2.9-mm-diameter (FAC group) and 3.75-mm-diameter (CM group) implants, using a pull-out test. The null hypothesis was that the tensile strengths of the components for both systems would be similar. MATERIAL AND METHODS: The fatigue properties of 13 specimens under 6 loads were determined. The test was performed at 15 Hz and for 5×106 cycles. In the pull-out test, the specimens were divided into 2 groups (n=8), the FAC group (2.9-mm-diameter) and the CM group (3.75-mm-diameter). Statistical analysis for the pull-out test was performed with the Student t test (α=.05). RESULTS: Thirteen specimens underwent the fatigue test. Only 5 did not fail when subjected to the frequency and number of cycles examined. Three of the specimens did not fail under a load of 130 N. The pull-out test showed a significant difference between the FAC and CM groups (P<.001). CONCLUSIONS: According to the fatigue test, the extra-narrow implant (Facility; Neodent) was compatible with the low masticatory effort regions, as indicated by the manufacturer. The better performance of the FAC group in the pull-out test may be due to its design, which promotes the pure Morse effect in the implant-abutment interface, and the angulation of its internal conical portion.


Subject(s)
Dental Abutments , Dental Implants , Dental Implant-Abutment Design , Dental Stress Analysis , Humans , Materials Testing , Stress, Mechanical
17.
Sensors (Basel) ; 19(1)2019 Jan 07.
Article in English | MEDLINE | ID: mdl-30621094

ABSTRACT

Wire-mesh sensors are used to determine the phase fraction of gas⁻liquid two-phase flow in many industrial applications. In this paper, we report the use of the sensor to study the flow behavior inside an offshore oil and gas industry device for subsea phase separation. The study focused on the behavior of gas⁻liquid slug flow inside a flow distribution device with four outlets, which is part of the subsea phase separator system. The void fraction profile and the flow symmetry across the outlets were investigated using tomographic wire-mesh sensors and a camera. Results showed an ascendant liquid film in the cyclonic chamber with the gas phase at the center of the pipe generating a symmetrical flow. Dispersed bubbles coalesced into a gas vortex due to the centrifugal force inside the cyclonic chamber. The behavior favored the separation of smaller bubbles from the liquid bulk, which was an important parameter for gas-liquid separator sizing. The void fraction analysis of the outlets showed an even flow distribution with less than 10% difference, which was a satisfactorily result that may contribute to a reduction on the subsea gas⁻liquid separators size. From the outcomes of this study, detailed information regarding this type of flow distribution system was extracted. Thereby, wire-mesh sensors were successfully applied to investigate a new type of equipment for the offshore oil and gas industry.

18.
Braz. j. oral sci ; 18: e191405, jan.-dez. 2019. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1087884

ABSTRACT

Aim: The crystallization step is required for lithium disilicate ceramics to change color, improve the mechanical properties and yield material to support mouth loading. Several furnaces could complete the crystallization process. This study evaluated the flexural and bond strength of lithium disilicate ceramics crystallized by different furnaces with the presence or not of vacum and different holding time. Methods: Forty lithium disilicate samples were divided into two groups: Programat P300 - control group with vacuum and holding time 7 minutes (CG) and FVPlus- experimental group and without vacuum and holding time 25 minutes (EG) and submitted to 2 experimental tests: 3-point flexural strength test and micro shear bond strength test (µSBS). For this test, the surface of the samples was treated and 1mm² of resin cement was applied on the surface. The samples were stored in artificial saliva over 2 time periods (24 hours: T0; 1-month storage: T1). To analyze the morphologic crystals of the ceramics tested, one representative specimen from each group were analyzed by using Scanning Electron Microscopy (SEM). Results: There was no significant difference in 3-point flexural strength test between groups CG and EG (p= 0.984). The µSBS results showed no statistical difference between groups, considering different storage time. There was no difference in the 3-point flexural strength and µSBS for lithium disilicate samples regardless of heat treatment of furnace type. The storage time had no influence on the µSBS. No differences were noted in the shape and size of these crystals when comparing the furnace analyzed by SEM images. Conclusion: Different furnaces did not influence the flexural and bond strength of lithium disilicate ceramics


Subject(s)
Ceramics , Lithium Compounds , Shear Strength
19.
Prosthes. Esthet. Sci ; 7(28): 55-60, jul-set 2018. ilus
Article in Portuguese | BBO - Dentistry | ID: biblio-946448

ABSTRACT

Alguns pacientes podem apresentar dificuldades motoras que inviabilizam a adequada higienização de próteses implantossuportadas. No entanto, a utilização de escovas elétricas pode compensar essas dificuldades e melhorar a qualidade de higiene oral. O presente trabalho relata um caso clínico que utilizou escova dental elétrica Philips Sonicar e AirFloss Ultra® como meio de higienização da área de implante osseointegrado exposta pós necrose óssea. Paciente dirigiu-se a um serviço de reabilitação oral com desconforto em prótese implantada ferulizada de três elementos localizada no arco inferior direito. Após análise clínica e diagnóstico, o paciente foi orientado quanto as etapas do tratamento, assim como a necessidade da manutenção dos tecidos peri-implantares através de uma correta higienização. Após um ano é possível verificar uma condição satisfatória da região avaliada e maior satisfação do paciente quanto ao método de limpeza empregado. (AU).


Some patients may present motor difficulties that prevent the adequate hygiene of implanted prosthesis. However, the use of electric toothbrushes can compensate these difficulties and improve the quality of oral hygiene. The present study reported the case of a patient who used Philips Sonicar electric brush and AirFloss Ultra® to clean an osseointegrated implant area exposed after bone necrosis. Patient went to an oral rehabilitation service with discomfort in a three-element splinted implanted prosthesis area, located in the lower right arch. After clinical analysis and diagnosis, the patient was advised on the steps of treatment as well as the necessity of the maintenance of the peri-implant tissues with a correct oral hygiene. After one year, it is still possible to verify a satisfactory condition of the evaluated region and greater satisfaction of the patient regarding the cleaning method employed. (AU).


Subject(s)
Humans , Male , Adult , Oral Hygiene , Quality of Life , Dental Prosthesis, Implant-Supported , Toothbrushing , Toothbrushing/instrumentation , Toothbrushing/methods
20.
Arq Neuropsiquiatr ; 76(7): 481-489, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30066800

ABSTRACT

Significant advances in the understanding and management of Duchenne muscular dystrophy (DMD) have occurred since the publication of international guidelines for DMD care in 2010. Our objective was to provide an evidence-based national consensus statement for multidisciplinary care of DMD in Brazil. A combination of the Delphi technique with a systematic review of studies from 2010 to 2016 was employed to classify evidence levels and grade of recommendations for the guideline. Our recommendations were divided in two parts. Guideline methodology and overall disease concept descriptions are found in Part 1. Here we present Part 2, where we provide the results and recommendations on rehabilitation and systemic care for DMD.


Subject(s)
Muscular Dystrophy, Duchenne/rehabilitation , Patient Care Team , Brazil , Consensus , Humans